Skip to main content
QUICK REVIEW

[Paper Review] Generalizable Medical Image Segmentation via Random Amplitude Mixup and Domain-Specific Image Restoration

Ziqi Zhou, Lei Qi|arXiv (Cornell University)|Aug 8, 2022
Medical Image Segmentation TechniquesComputer Science7 citations
TL;DR

This paper proposes a novel domain generalization method for medical image segmentation using random amplitude mixup (RAM) and domain-specific image restoration (DSIR) to improve model robustness across diverse imaging domains. By synthesizing stylized images via Fourier-based amplitude mixing and training a self-supervised restoration head, the method enhances feature generalization and achieves state-of-the-art performance on fundus and prostate segmentation benchmarks.

ABSTRACT

For medical image analysis, segmentation models trained on one or several domains lack generalization ability to unseen domains due to discrepancies between different data acquisition policies. We argue that the degeneration in segmentation performance is mainly attributed to overfitting to source domains and domain shift. To this end, we present a novel generalizable medical image segmentation method. To be specific, we design our approach as a multi-task paradigm by combining the segmentation model with a self-supervision domain-specific image restoration (DSIR) module for model regularization. We also design a random amplitude mixup (RAM) module, which incorporates low-level frequency information of different domain images to synthesize new images. To guide our model be resistant to domain shift, we introduce a semantic consistency loss. We demonstrate the performance of our method on two public generalizable segmentation benchmarks in medical images, which validates our method could achieve the state-of-the-art performance.

Motivation & Objective

  • Address the challenge of poor generalization in medical image segmentation models trained on limited source domains with distribution shifts.
  • Overcome overfitting to source domains and domain shift by introducing stronger model regularization.
  • Improve robustness to unseen target domains without requiring access to target domain data.
  • Develop a self-supervised training paradigm that enhances domain-invariant feature learning through image reconstruction and consistency loss.
  • Demonstrate state-of-the-art performance on public domain generalization benchmarks for fundus and prostate image segmentation.

Proposed method

  • Introduce a random amplitude mixup (RAM) module that applies Fourier transform to extract amplitude maps from two different domain images and combines them to generate new, stylized images with mixed domain characteristics.
  • Use the synthesized images from RAM as data augmentation to train the segmentation model, increasing diversity in the training distribution.
  • Implement a self-supervised domain-specific image restoration (DSIR) module that reconstructs original source-domain images from the RAM-augmented images, enforcing feature consistency and robustness.
  • Train the segmentation model with a multi-task loss combining standard segmentation loss, semantic consistency loss between real and augmented image predictions, and image reconstruction loss from the DSIR module.
  • Apply a semantic consistency loss to minimize prediction discrepancies between real source images and their RAM-augmented counterparts, promoting domain-invariant representation learning.
  • Optimize the entire network end-to-end using a combination of segmentation, consistency, and reconstruction losses to improve generalization to unseen domains.

Experimental results

Research questions

  • RQ1Can random amplitude mixup effectively synthesize diverse, domain-mixed images that improve segmentation generalization without requiring target domain data?
  • RQ2Does incorporating a self-supervised domain-specific image restoration module enhance feature robustness and model generalization in medical image segmentation?
  • RQ3How effective is the semantic consistency loss in reducing prediction variance across domain-shifted inputs?
  • RQ4To what extent do the RAM and DSIR components individually and jointly improve performance on unseen target domains in medical image segmentation?
  • RQ5Is the proposed method robust to different types of consistency loss functions in the training objective?

Key findings

  • The proposed RAM-DSIR method achieves state-of-the-art performance on two public domain generalization benchmarks for fundus and prostate image segmentation.
  • Ablation studies show that adding the RAM module improves Dice score by 2.12% on the fundus dataset and 3.23% on the prostate dataset compared to the baseline.
  • The DSIR module contributes an additional 1.58% and 1.03% improvement in Dice score on the fundus and prostate datasets, respectively.
  • The semantic consistency loss significantly improves generalization, as its removal leads to consistent performance degradation across both datasets.
  • The method is robust to different consistency loss types—MSE, JS-Div, and KL-Div—yielding comparable performance, with KL-Div achieving the highest overall Dice score of 88.94% on the fundus dataset.
  • The full model with all components achieves the best performance, confirming the complementary roles of RAM, DSIR, and semantic consistency in enhancing domain generalization.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.