[Paper Review] Geometry OR Tracker: Universal Geometric Operating Room Tracking
Geometry OR Tracker introduces a two-stage pipeline that rectifies noisy OR calibration to produce metric, occlusion-robust 3D tracking in a shared operating-room frame, improving cross-view consistency and trajectory quality.
In operating rooms (OR), world-scale multi-view 3D tracking supports downstream applications such as surgeon behavior recognition, where physically meaningful quantities such as distances and motion statistics must be measured in meters. However, real clinical deployments rarely satisfy the geometric prerequisites for stable multi-view fusion and tracking: camera calibration and RGB-D registration are always unreliable, leading to cross-view geometric inconsistency that produces "ghosting" during fusion and degrades 3D trajectories in a shared OR coordinate frame. To address this, we introduce Geometry OR Tracker, a two-stage pipeline that first rectifies imprecise calibration into a scaleconsistent and geometrically consistent camera setup with a single global scale via a Multi-view Metric Geometry Rectification module, and then performs Occlusion-Robust 3D Point Tracking directly in the unified OR world frame. On the MM-OR benchmark, improved geometric consistency translates into tracking gains: our rectification front-end reduces cross-view depth disagreement by more than 30$ imes$ compared to raw calibration. Ablation studies further demonstrate the relationship between calibration quality and tracking accuracy, showing that improved geometric consistency yields stronger world-frame tracking.
Motivation & Objective
- Motivate metric-accurate 3D tracking in operating rooms despite unreliable camera calibration and RGB-D misalignment.
- Propose a two-stage pipeline that first rectifies calibration to a global metric geometry, then performs occlusion-robust 3D point tracking in the OR frame.
- Demonstrate the impact of geometric consistency on downstream tracking performance on MM-OR with ablations.
- Show that rectification improves cross-view depth consistency and reduces ghosting during fusion.
Proposed method
- Stage 1: Multi-view Metric Calibration Rectification that predicts a global metric scale, rectified intrinsics, rectified poses, and per-frame rectified depth from noisy inputs.
- Back-project rectified depth to 3D camera points, transform to the shared room frame, and obtain metric point maps with global scale m.
- Stage 2: Occlusion-Robust Metric 3D Point Tracking that fuses multi-view observations into a 3D feature cloud in the OR frame and tracks 3D query points with local 3D neighborhood retrieval and iterative refinement.
- Use a pretrained multi-view tracker to update 3D trajectories in the rectified metric space under occlusions.
Experimental results
Research questions
- RQ1Can geometry-consistent rectification of noisy OR calibrations enable reliable metric 4D reconstruction and tracking?
- RQ2How does improving cross-view geometric consistency affect 3D tracking accuracy and robustness under occlusions?
- RQ3What inputs for rectification (RGB, depth, intrinsics, extrinsics) yield the best depth accuracy and downstream tracking performance?
- RQ4What is the relationship between metric depth quality and world-frame tracking accuracy in operating rooms?
Key findings
- Rectification markedly reduces cross-view depth disagreement compared to raw calibration (mean error and median error drop from 1.4115 m and 1.4151 m to 0.0459 m and 0.0204 m).
- The full geometry-consistent pipeline achieves the best tracking metrics on MM-OR (AJ 89.73, Delta_avg 93.65, OA 96.28, MTE 3.46).
- MMCR ablation shows that removing rectification degrades tracking across AJ, Delta_avg, and OA but can reduce MTE, highlighting the trade-off between cross-view consistency and drift under certain configurations.
- Rectification inputs with RGB, depth, intrinsics, and pose yield the best depth accuracy (AbsRel 0.060, RMSE 0.653) and strongest tracking (AJ 74.78 with partial inputs; full inputs give best overall tracking).
- Better rectification yields stronger cross-view metric consistency, reduces fusion ghosting, and stabilizes 3D neighborhood retrieval under occlusions.
- The proposed method consistently outperforms representative baselines (MVTracker, CoTracker3, SpaTrackerV2, etc.) on 3D tracking metrics.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.