[Paper Review] Glottal Closure Instants Detection From Pathological Acoustic Speech Signal Using Deep Learning
This paper proposes a deep learning-based method for detecting glottal closure instants (GCI) in pathological speech using raw acoustic signals and linear prediction residual (LPR) features, fusing them via a multi-column CNN architecture. The approach achieves 89.30% identification rate and 0.54ms timing accuracy, significantly outperforming state-of-the-art methods on a novel pathological speech dataset with manual GCI annotations.
In this paper, we propose a classification based glottal closure instants (GCI) detection from pathological acoustic speech signal, which finds many applications in vocal disorder analysis. Till date, GCI for pathological disorder is extracted from laryngeal (glottal source) signal recorded from Electroglottograph, a dedicated device designed to measure the vocal folds vibration around the larynx. We have created a pathological dataset which consists of simultaneous recordings of glottal source and acoustic speech signal of six different disorders from vocal disordered patients. The GCI locations are manually annotated for disorder analysis and supervised learning. We have proposed convolutional neural network based GCI detection method by fusing deep acoustic speech and linear prediction residual features for robust GCI detection. The experimental results showed that the proposed method is significantly better than the state-of-the-art GCI detection methods.
Motivation & Objective
- To address the lack of robust GCI detection methods for pathological speech, which often rely on invasive EGG signals.
- To develop a data-driven, end-to-end deep learning approach that bypasses manual parameter tuning and hand-crafted heuristics.
- To enable GCI detection directly from standard acoustic speech signals recorded via smartphones or low-cost devices.
- To create a new pathological speech dataset with simultaneous EGG and acoustic recordings for research validation.
- To improve detection accuracy and robustness in the presence of weak or smeared glottal excitation due to vocal fold disorders.
Proposed method
- A multi-column 3D-CNN architecture is used, with each column processing a different input representation: low-pass filtered speech (LPF_S), low-pass filtered LPR (LPF_LPR), and positive-clipped versions of both.
- Each CNN block consists of five convolutional layers with batch normalization, omitting max pooling to preserve fine temporal variations in GCI regions.
- The final layer uses a sigmoid activation to output posterior probability per frame for GCI classification.
- A joint model combines features from the acoustic (LPF_S) and residual (PC_LPF_LPR) branches using late fusion via maximum likelihood combination of predicted probabilities.
- The final GCI is identified as the location of the maximum negative peak within frames classified as GCI (probability ≥ 0.1).
- The model is trained using binary cross-entropy loss with ADAM optimizer and He normal weight initialization over 30 epochs.
Experimental results
Research questions
- RQ1Can a deep learning model trained on raw acoustic and LPR features detect GCI in pathological speech more accurately than traditional signal-processing-based methods?
- RQ2Does fusing acoustic and residual features improve GCI detection robustness across diverse vocal disorders?
- RQ3How does the proposed method compare to state-of-the-art GCI detection techniques (SEDREAMS, DYPSA, ZFF) in terms of identification rate, miss rate, and timing accuracy?
- RQ4Can a single deep learning model generalize across multiple types of vocal fold disorders without requiring disorder-specific tuning?
- RQ5To what extent do positive clipping and low-pass filtering of speech and LPR signals improve GCI detection performance in pathological cases?
Key findings
- The proposed method achieved an identification rate (IDR) of 89.30%, significantly outperforming SEDREAMS (84.98%), DYPSA (79.33%), and ZFF (80.88%).
- The miss rate (MR) was 5.97%, lower than SEDREAMS (9.06%), DYPSA (13.42%), and ZFF (10.64%), indicating fewer missed GCI events.
- The false alarm rate (FAR) was 4.70%, lower than SEDREAMS (6.01%), DYPSA (7.25%), and ZFF (8.48%), showing improved specificity.
- The identification accuracy (IDA) was 0.54ms, the lowest among all methods, indicating high temporal precision in GCI localization.
- Model 1 (LPF_S) achieved the highest individual F1-score (86.82%), while Model 4 (PC_LPF_LPR) minimized false alarms by suppressing secondary excitations.
- Late fusion of LPF_S and PC_LPF_LPR features via maximum likelihood combination yielded the best overall performance, confirming complementary benefits of acoustic and residual representations.
Read this paper