[Paper Review] H\"older stability of quantitative photoacoustic tomography based on partial data
This paper establishes Hölder stability for reconstructing diffusion and absorption coefficients in quantitative photoacoustic tomography (PAT) from partial internal data near the boundary, using a novel stability analysis of a Cauchy problem for √D. The method achieves improved stability as the subregion contracts toward the boundary, with the Hölder exponent converging to a positive constant independent of the subregion, validated by numerical reconstructions of smooth and discontinuous media with low relative errors (3–8.5%).
We consider the reconstruction of the diffusion and absorption coefficients of the diffusion equation from the internal information of the solution obtained from the first step of the inverse photoacoustic tomography (PAT). In practice, the internal information is only partially provided near the boundary due to the high absorption property of the medium and the limitation of the equipment. Our main contribution is to prove a H\"older stability of the inverse problem in a subregion where the internal information is reliably provided based on the stability estimation of a Cauchy problem satisfied by the diffusion coefficient. The exponent of the H\"older stability converges to a positive constant independent of the subregion as the subregion contracts towards the boundary. Numerical experiments demonstrates that it is possible to locally reconstruct the diffusion and absorption coefficients for smooth and even discontinuous media.
Motivation & Objective
- Address the lack of stability analysis for quantitative PAT when internal data H(x) is only available near the boundary due to tissue absorption and measurement limitations.
- Prove Hölder stability for reconstructing diffusion D(x) and absorption µ(x) in a subregion close to the measurement boundary using partial internal data.
- Overcome the limitation of existing Cauchy problem stability estimates, which diverge as the subregion approaches the boundary, by deriving a bound independent of subregion size.
- Demonstrate the feasibility of local reconstruction for both smooth and discontinuous media under realistic partial-data conditions.
Proposed method
- Formulate a Cauchy problem for √D based on internal data H(x) = µ(x)u(x), assuming Γ ≡ 1.
- Derive a system of equations involving ∇lnσ where σ = D|u₁|², using ratios of solutions uⱼ/u₁ to recover ∇lnσ from Hⱼ/H₁.
- Reconstruct the coefficient and source terms of the elliptic equation for √D using numerical differentiation and filtering to mitigate noise amplification.
- Complete the missing data in the Cauchy problem by extrapolating with background or average values, minimizing impact on the reconstruction near the known region.
- Apply a stable numerical scheme to solve the elliptic PDE for √D only in a subregion where H(x) exceeds a noise-dependent threshold.
- Use the identity Δ√σ / √σ = ½|∇lnσ|² + ½div(∇lnσ) to compute the coefficient term, avoiding direct differentiation of σ.
Experimental results
Research questions
- RQ1Can Hölder stability be established for the inverse problem of reconstructing D and µ in PAT when internal data H(x) is only available near the boundary?
- RQ2Does the stability estimate remain bounded and non-degenerate as the reconstruction subregion approaches the measurement boundary?
- RQ3Can the reconstruction method handle both smooth and discontinuous media under partial-data conditions?
- RQ4How does the Hölder exponent of the stability estimate behave as the subregion shrinks toward the boundary?
- RQ5To what extent does numerical noise and derivative amplification affect the reconstruction quality in practice?
Key findings
- The Hölder stability exponent for reconstructing D and µ converges to a positive constant independent of the subregion as the subregion contracts toward the boundary, indicating improved stability near the illumination source.
- Numerical reconstructions of smooth media achieve relative errors of 3.42% for D and 3.19% for µ in the region y > 0.2, demonstrating high accuracy.
- For discontinuous media, the algorithm successfully reconstructs inclusions with relative errors of 8.56% for D and 4.70% for µ in the same region, despite derivative amplification near discontinuities.
- The blood vessel model reconstruction shows relative errors of 4.74% for D and 2.47% for µ, confirming robustness on realistic biological structures.
- The method remains stable and accurate even when filtering techniques reduce true extreme values on discontinuity boundaries, indicating resilience to numerical noise.
- The reconstruction is localized and effective only in subregions where H(x) exceeds a noise threshold, confirming the method's practical feasibility under partial data.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.