[Paper Review] Hand range of motion evaluation for Rheumatoid Arthritis patients

Luciano Walenty Xavier Cejnog, Roberto M. César|arXiv (Cornell University)|Mar 16, 2019
Hand Gesture Recognition SystemsComputer Science23 references3 citations
TL;DR

This paper proposes a real-time computer vision framework using depth sensing and 3D hand pose estimation (Pose-REN) to automatically assess finger range of motion in Rheumatoid Arthritis (RA) patients. By computing flexion and abduction angles relative to a dynamically estimated palm plane, the system enables non-invasive, patient-friendly dynamic evaluation that discriminates RA and healthy hand movement patterns with high feasibility and minimal intervention.

ABSTRACT

We introduce a framework for dynamic evaluation of the fingers movements: flexion, extension, abduction and adduction. This framework estimates angle measurements from joints computed by a hand pose estimation algorithm using a depth sensor (Realsense SR300). Given depth maps as input, our framework uses Pose-REN, which is a state-of-art hand pose estimation method that estimates 3D hand joint positions using a deep convolutional neural network. The pose estimation algorithm runs in real-time, allowing users to visualise 3D skeleton tracking results at the same time as the depth images are acquired. Once 3D joint poses are obtained, our framework estimates a plane containing the wrist and MCP joints and measures flexion/extension and abduction/aduction angles by applying computational geometry operations with respect to this plane. We analysed flexion and abduction movement patterns using real data, extracting the movement trajectories. Our preliminary results show that this method allows an automatic discrimination of hands with Rheumatoid Arthritis (RA) and healthy patients. The angle between joints can be used as an indicative of current movement capabilities and function. Although the measurements can be noisy and less accurate than those obtained statically through goniometry, the acquisition is much easier, non-invasive and patient-friendly, which shows the potential of our approach. The system can be used with and without orthosis. Our framework allows the acquisition of measurements with minimal intervention and significantly reduces the evaluation time.

Motivation & Objective

  • To develop a non-invasive, automated method for dynamic hand range of motion evaluation in Rheumatoid Arthritis (RA) patients to support occupational therapy.
  • To address the limitations of traditional goniometry by reducing evaluation time and patient burden through computer vision-based motion tracking.
  • To enable accurate, real-time estimation of flexion and abduction angles using depth sensor data and 3D hand pose estimation.
  • To evaluate the feasibility of the system in both RA patients and healthy controls, including cases with orthoses.
  • To provide a computational geometry-based method for estimating joint angles from 3D skeleton data for clinical use in functional assessment.

Proposed method

  • Uses depth maps from a Realsense SR300 sensor as input for real-time 3D hand pose estimation via Pose-REN, a deep convolutional neural network.
  • Estimates a palm plane using the normal vector derived from the wrist and the metacarpophalangeal (MCP) joints of the index and little fingers (MCP₂, MCP₅, and W).
  • Computes flexion angles using the arccosine of the dot product between consecutive joint vectors (e.g., MCP→PIP and PIP→DIP).
  • Estimates abduction angles by projecting the PIP→MCP vector onto the palm plane and measuring the angle between this projection and the MCP→W vector.
  • Applies geometric operations to compute joint angles frame-by-frame during dynamic hand movements.
  • Processes sequences of depth images to extract movement trajectories and compute average angle values and standard deviations for comparison between groups.

Experimental results

Research questions

  • RQ1Can a depth-based computer vision system accurately estimate dynamic range of motion angles (flexion and abduction) in RA patients compared to manual goniometry?
  • RQ2How does the system perform in distinguishing movement patterns between RA patients and healthy controls during functional hand movements?
  • RQ3To what extent does the presence of an orthosis affect the accuracy and reliability of the pose estimation and angle computation?
  • RQ4Can the framework provide a non-invasive, real-time, and patient-friendly alternative to conventional goniometric measurements in occupational therapy?
  • RQ5How do the computed angle trajectories reflect functional limitations in RA patients, particularly in hand opening and extension?

Key findings

  • The system successfully extracted flexion and abduction angle trajectories from real-time depth data, showing clear patterns corresponding to hand opening and closing.
  • Local maxima and minima in the angle curves corresponded to fully open and fully closed hand postures, as confirmed by frame-level visualization.
  • RA patients exhibited reduced maximum flexion angles and difficulty maintaining full hand opening, particularly evident in the initial phase of movement.
  • The average flexion angle values and standard deviations for RA patients were comparable to controls, but with a statistically noticeable reduction in range and higher variability in early movement phases.
  • The system maintained performance with orthoses, showing slightly lower standard deviations in movement, indicating more constrained but consistent motion patterns.
  • Despite some noise and lower absolute accuracy than goniometry, the method enables faster, less intrusive, and repeatable assessment, making it suitable for clinical monitoring.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.