[Paper Review] Heart Sound Classification Considering Additive Noise and Convolutional Distortion
This paper proposes a novel feature fusion method combining linear filterbank (Fbank) and Mel-frequency cepstral coefficient (MFCC) features for robust heart sound classification under additive noise and sensor-induced convolutional distortion. Using a residual CNN (ResNet) on fused Fbank and MFCC-13 features, the method achieves 91.36% AUC, 84.09% F1-score, and 85.08% Macc—significantly outperforming prior methods, especially in noisy and multi-stethoscope environments.
Cardiac auscultation is an essential point-of-care method used for the early diagnosis of heart diseases. Automatic analysis of heart sounds for abnormality detection is faced with the challenges of additive noise and sensor-dependent degradation. This paper aims to develop methods to address the cardiac abnormality detection problem when both types of distortions are present in the cardiac auscultation sound. We first mathematically analyze the effect of additive and convolutional noise on short-term filterbank-based features and a Convolutional Neural Network (CNN) layer. Based on the analysis, we propose a combination of linear and logarithmic spectrogram-image features. These 2D features are provided as input to a residual CNN network (ResNet) for heart sound abnormality detection. Experimental validation is performed on an open-access heart sound abnormality detection dataset involving noisy recordings obtained from multiple stethoscope sensors. The proposed method achieves significantly improved results compared to the conventional approaches, with an area under the ROC (receiver operating characteristics) curve (AUC) of 91.36%, F-1 score of 84.09%, and Macc (mean of sensitivity and specificity) of 85.08%. We also show that the proposed method shows the best mean accuracy across different source domains including stethoscope and noise variability, demonstrating its effectiveness in different recording conditions. The proposed combination of linear and logarithmic features along with the ResNet classifier effectively minimizes the impact of background noise and sensor variability for classifying phonocardiogram (PCG) signals. The proposed method paves the way towards developing computer-aided cardiac auscultation systems in noisy environments using low-cost stethoscopes.
Motivation & Objective
- Address the combined challenge of additive noise and convolutional distortion in heart sound classification, which degrade performance in real-world point-of-care settings.
- Improve robustness of automatic heart sound analysis across diverse stethoscope sensors and noisy recording conditions.
- Develop a feature engineering approach that minimizes the impact of both background noise and sensor variability on classification performance.
- Demonstrate superior generalization across source domains (different stethoscopes and noise levels) compared to existing methods.
- Validate the effectiveness of combining linear and logarithmic spectrogram features in a deep learning framework for PCG signal classification.
Proposed method
- Mathematically analyze the effects of additive and convolutional distortions on short-term filterbank features and CNN layers to inform robust feature design.
- Extract linear filterbank energy (Fbank) and Mel-frequency cepstral coefficient (MFCC-13) features from PCG signals as complementary representations.
- Fuse Fbank and MFCC-13 features into a 2D input matrix to preserve temporal and spectral dynamics for deep learning.
- Employ a residual convolutional neural network (ResNet) as the classifier to learn hierarchical patterns from the fused spectrogram features.
- Use domain-balanced training (DBT) to ensure fair evaluation across different stethoscope sensors and noise conditions.
- Apply McNemar’s chi-squared test to statistically validate performance improvements over baseline models.
Experimental results
Research questions
- RQ1How do additive noise and convolutional distortion jointly affect the performance of heart sound classification systems?
- RQ2Can the fusion of linear filterbank energy and logarithmic Mel-spectrogram features improve robustness to noise and sensor variability?
- RQ3Does the proposed feature fusion strategy lead to statistically significant performance gains over existing methods in noisy and multi-source environments?
- RQ4How does the proposed method generalize across different stethoscope sensors and noise levels compared to prior approaches?
- RQ5Is the improvement in classification performance due to the feature fusion strategy, rather than random variation or data leakage?
Key findings
- The proposed method achieves an area under the ROC curve (AUC) of 91.36%, representing a significant improvement over baseline models.
- The method attains an F1-score of 84.09% and a mean of sensitivity and specificity (Macc) of 85.08%, demonstrating strong overall performance.
- The fusion of Fbank and MFCC-13 features yields a statistically significant improvement (p < 0.05) over the Potes-CNN-DBT baseline system, as confirmed by McNemar’s test.
- The method shows the highest mean accuracy across different source domains, including various stethoscopes and noise levels, indicating strong generalization.
- The improvement over Humayun et al.’s tConv-CNN-DBT system is 3.59% in Macc, though not statistically significant (p > 0.05), suggesting consistent but not extreme gains.
- TSNE visualization shows no meaningful clustering by source domain, indicating the model learns invariant representations despite domain shift.