[Paper Review] Hepatic vessel segmentation using a reduced filter 3D U-Net in ultrasound imaging
This study proposes a reduced filter 3D U-Net for accurate hepatic vessel segmentation in 3D and stacked 2D ultrasound volumes, achieving Dice scores of 0.740 and 0.781 respectively, demonstrating robust performance despite limited data and challenging image noise, with results approaching inter-observer variability.
Accurate hepatic vessel segmentation on ultrasound (US) images can be an important tool in the planning and execution of surgery, however proves to be a challenging task due to noise and speckle. Our method comprises a reduced filter 3D U-Net implementation to automatically detect hepatic vasculature in 3D US volumes. A comparison is made between volumes acquired with a 3D probe and stacked 2D US images based on electromagnetic tracking. Experiments are conducted on 67 scans, where 45 are used in training, 12 in validation and 10 in testing. This network architecture yields Dice scores of 0.740 and 0.781 for 3D and stacked 2D volumes respectively, comparing promising to literature and inter-observer performance (Dice = 0.879).
Motivation & Objective
- To develop a deep learning-based method for automatic hepatic vessel segmentation in 3D and 2D ultrasound imaging to support intraoperative surgical planning.
- To address the challenge of speckle noise and low contrast in ultrasound that hinders accurate vessel delineation.
- To compare segmentation performance between true 3D ultrasound and 2D images stacked using electromagnetic tracking.
- To evaluate the method's performance against inter-observer variability and existing literature.
- To explore the feasibility of using the segmentation for future navigation surgery applications, including registration with MRI.
Proposed method
- A reduced filter 3D U-Net architecture is implemented with one-eighth the number of filters per layer to reduce computational load and avoid GPU memory bottlenecks.
- The network is trained using Dice loss with Adam optimizer, L1 regularization, and data augmentation including rotation, scaling, and elastic deformation.
- Input volumes are preprocessed with a 3-pixel median filter to reduce noise and normalized using mean intensity values.
- Training uses 217 epochs on four NVIDIA 1080 GTX GPUs, with 20 patches of size 152×152×96 extracted per volume after downsampling to 40% resolution.
- 3D and 2D US volumes are both processed using the same network, with padding of 32×32×32 to maintain spatial consistency.
- Segmentation performance is evaluated using Dice and IoU metrics on test sets of 10 3D and 7 stacked 2D scans.
Experimental results
Research questions
- RQ1Can a reduced filter 3D U-Net achieve robust hepatic vessel segmentation in noisy 3D and stacked 2D ultrasound volumes?
- RQ2How does the segmentation performance of the proposed method compare to inter-observer variability in vessel delineation?
- RQ3Does the acquisition method (true 3D vs. electromagnetic-tracked 2D stacks) significantly affect segmentation accuracy?
- RQ4Can the learned features from the network be generalized across different US acquisition modalities?
- RQ5Is the segmentation quality sufficient for potential use in surgical navigation systems, such as centerline-based registration with MRI?
Key findings
- The reduced filter 3D U-Net achieved a mean Dice score of 0.740 ± 0.02 on 3D ultrasound volumes, indicating strong segmentation performance.
- For stacked 2D ultrasound volumes, the method achieved a Dice score of 0.781 ± 0.07, outperforming the 3D modality and showing promise for clinical use.
- The inter-observer variability was higher, with a Dice score of 0.879 ± 0.02, indicating that the model's performance is close to human expert consistency.
- The model showed under-segmentation of the inferior vena cava, particularly near volume edges, likely due to incomplete vessel cross-section visibility and large volume contribution.
- IoU scores were 0.584 ± 0.02 for 3D and 0.645 ± 0.09 for 2D volumes, supporting the Dice results and indicating good overlap with ground truth.
- No significant performance difference was observed between 3D and 2D acquisition methods, suggesting the model generalizes well across modalities.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.