Skip to main content
QUICK REVIEW

[Paper Review] Heterogeneous Multi-sensor Calibration based on Graph Optimization

Hongyu Chen, Sören Schwertfeger|arXiv (Cornell University)|May 27, 2019
Robotics and Sensor-Based LocalizationEngineering25 references5 citations
TL;DR

This paper proposes a graph optimization-based method for extrinsic calibration of heterogeneous multi-sensor systems, using pairwise calibration results as initial estimates and refining them globally via a hypergraph framework. The approach reduces calibration errors significantly, demonstrating improved accuracy on both synthetic and real-world data from a 12-sensor mapping robot platform.

ABSTRACT

Many robotics and mapping systems contain multiple sensors to perceive the environment. Extrinsic parameter calibration, the identification of the position and rotation transform between the frames of the different sensors, is critical to fuse data from different sensors. When obtaining multiple camera to camera, lidar to camera and lidar to lidar calibration results, inconsistencies are likely. We propose a graph-based method to refine the relative poses of the different sensors. We demonstrate our approach using our mapping robot platform, which features twelve sensors that are to be calibrated. The experimental results confirm that the proposed algorithm yields great performance.

Motivation & Objective

  • To address inconsistencies in pairwise extrinsic calibration results among multiple heterogeneous sensors (cameras, 3D lidars) on a robotic platform.
  • To develop a global optimization framework that refines relative poses using a hypergraph representation of sensor relationships.
  • To improve calibration accuracy beyond individual pairwise calibrations by leveraging consistency across all sensor pairs.
  • To enable accurate sensor fusion for applications like 3D SLAM and robotic mapping by achieving precise multi-sensor alignment.

Proposed method

  • Construct a hypergraph with 12 vertices (sensors) and 59 edges (pairwise sensor transformations), representing known relative poses from initial calibrations.
  • Model sensor-to-sensor transformations using Lie algebra, with error defined via the logarithmic map of the transformation difference: $ e_{ij} = \ln(T_{ij}^{-1} T_i^{-1} T_j)^\vee $.
  • Use the G2O library to perform nonlinear optimization on the hypergraph to minimize the global error $ E_{global} = \frac{1}{N_E} \sum_{i=1}^{N_E} e_i^2 $.
  • Estimate covariance matrices for hyperedges using the Jackknife resampling method to weight uncertainty in the optimization process.
  • Apply the method to real data from a 12-sensor robot platform, including 9 cameras, 2 3D lidars, and an OptiTrack tracking system for ground truth.
  • Validate results by fusing lidar point clouds with camera images and evaluating geometric consistency in the fused output.

Experimental results

Research questions

  • RQ1Can a global graph optimization framework effectively reduce inconsistencies in pairwise extrinsic calibration results among heterogeneous sensors?
  • RQ2How does the proposed method improve calibration accuracy compared to individual pairwise calibrations?
  • RQ3To what extent does the use of Jackknife-based covariance estimation enhance the robustness of the optimization?
  • RQ4Can the method achieve consistent and accurate multi-sensor alignment in real-world robotic platforms with complex sensor configurations?

Key findings

  • The global optimization reduced the average calibration error from 0.0149 m to 0.0126 m, demonstrating a measurable improvement in translation accuracy.
  • Synthetic experiments showed that the variance of the optimized transformation errors was lower than the noise level added to the initial pairwise estimates.
  • The fused 3D point cloud with color data (Fig. 6) showed consistent alignment, with well-represented color checkerboards and minimal misregistration.
  • The method successfully calibrated 36 camera pairs (including 4 stereo pairs and 32 non-overlapping pairs) and 13 lidar-to-camera pairs using a unified framework.
  • The use of the OptiTrack system enabled high-accuracy ground truth validation, confirming the reliability of the optimized calibration results.
  • The approach is extensible, with future work planned to include IMUs, 2D lidars, and the robot’s motion base in the hypergraph.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.