This study evaluates the precision of Higgs boson mass and Higgs-strahlung cross-section measurements at the International Linear Collider using the ILD detector concept. Based on full simulation with 250 fb⁻¹ luminosity and beam polarization, it achieves 37 MeV mass resolution and 3.3% cross-section accuracy in the $ZH \to \mu^+\mu^-X$ channel, demonstrating the feasibility of high-precision Higgs physics via recoil mass reconstruction and optimized background suppression.

ABSTRACT

This proceeding summarizes the Higgs recoil mass and Higgs-strahlung cross-section study done for the Letter of Intent (LOI) of the International Large Detector (ILD) Concept. Assuming a Higgs mass of 120 GeV, working at 250 GeV center of mass energy with beam parameters RDR250 and beam polarization, this full simulation study predicts that, the ILD detector can achieve 37 MeV precision on the Higgs mass measurement and 3.3% on the cross-section measurement from the muon channel, while 83 MeV and 4.9% from the electron channel, if we have 250 inverse fb integrated luminosity.

Motivation & Objective

  • To assess the precision of Higgs boson mass measurement via the recoil mass method in the $ZH \to \ell^+\ell^-X$ channel at the ILC.
  • To evaluate the accuracy of Higgs-strahlung cross-section measurement independent of Higgs decay modes.
  • To quantify the impact of beam energy spread and Beamstrahlung on recoil mass resolution.
  • To develop and validate a background suppression strategy combining kinematic cuts, $P_T$ balance, and likelihood-based methods.
  • To identify and mitigate systematic errors in mass and cross-section measurements, particularly from detector response and efficiency uncertainties.

Proposed method

  • Full simulation using ILCSoft v01-06 with ILD detector geometry and beam parameters from the ILC RDR, including beam energy spread and Beamstrahlung effects.
  • Event generation with WHIZARD v1.40 including initial- and final-state radiation, using beam parameters from GUINEA-PIG simulations.
  • Event selection via lepton identification, kinematic cuts on $M_{dl}$, $P_{Tdl}$, $\cos\theta_{dl}$, acoplanarity, and recoil mass window.
  • Background suppression using $P_T$ balance to distinguish ISR-dominated $\ell\ell$ backgrounds from $ZH$ signal, and likelihood-based rejection of $WW/ZZ$ backgrounds.
  • Calibration of tracking momentum and center-of-mass energy using $ZZ \to \mu^+\mu^-X$ as a reference process with 13 MeV invariant mass resolution.
  • Systematic error estimation via variation of physics assumptions and background rejection methods to assess efficiency uncertainty and its covariance.

Experimental results

Research questions

  • RQ1What is the achievable precision in Higgs boson mass measurement using the recoil mass method in the $ZH \to \mu^+\mu^-X$ and $ZH \to e^+e^-X$ channels?
  • RQ2How do beam energy spread and Beamstrahlung affect the resolution of the Higgs recoil mass distribution?
  • RQ3To what extent can $P_T$ balance and likelihood-based methods suppress irreducible $WW$, $ZZ$, and $\ell\ell$ backgrounds?
  • RQ4What systematic errors arise in the Higgs mass and cross-section measurements, and how can they be calibrated using reference processes?
  • RQ5How does the complexity of background rejection affect the uncertainty in cross-section measurements?

Key findings

  • The ILD detector achieves a Higgs mass resolution of 37 MeV in the $ZH \to \mu^+\mu^-X$ channel and 83 MeV in the $ZH \to e^+e^-X$ channel with 250 fb⁻¹ luminosity.
  • The Higgs-strahlung cross-section is measured with a precision of 3.3% in the $\mu\mu X$ channel and 4.9% in the $eeX$ channel under the same conditions.
  • The dominant contribution to recoil mass resolution comes from beam effects (energy spread and Beamstrahlung), not detector response, with detector-induced broadening contributing 330 MeV to the 650 MeV total width.
  • The $P_T$ balance method effectively suppresses $\ell\ell$ background, while likelihood-based suppression reduces $WW/ZZ$ backgrounds by 50%.
  • Using $ZZ \to \mu^+\mu^-X$ as a reference process, the $Z$ boson mass is measured with 13 MeV precision, and the recoil mass with 28 MeV precision, enabling calibration of center-of-mass energy and radiative effects.
  • Removing the likelihood-based background suppression increases the cross-section statistical error by only 10%, indicating that simpler methods can achieve comparable precision with reduced systematic uncertainty.