TL;DR

This paper proposes the primary components conditional hierarchical VAE (pchVAE), a novel variational autoencoder architecture that decomposes images into high-level (coarse) and low-level (fine) components using a dedicated reconstruction branch. By enforcing disentanglement through a modified loss function, pchVAE achieves sharper reconstructions than standard VAEs while maintaining or slightly improving out-of-distribution detection performance, addressing the common issue of over-smoothed outputs in medical image generation.

ABSTRACT

Variational Auto-Encoders have often been used for unsupervised pretraining, feature extraction and out-of-distribution and anomaly detection in the medical field. However, VAEs often lack the ability to produce sharp images and learn high-level features. We propose to alleviate these issues by adding a new branch to conditional hierarchical VAEs. This enforces a division between higher-level and lower-level features. Despite the additional computational overhead compared to a normal VAE it results in sharper and better reconstructions and can capture the data distribution similarly well (indicated by a similar or slightly better OoD detection performance).

Motivation & Objective

  • To address the over-smoothing problem in standard VAEs when applied to medical image reconstruction.
  • To improve disentanglement between high-level (coarse) and low-level (fine) image features in unsupervised representation learning.
  • To maintain or enhance out-of-distribution (OoD) detection performance despite architectural modifications.
  • To enable better reconstruction fidelity in brain MRI data by explicitly modeling structural hierarchy.
  • To provide a more interpretable and modular VAE framework for medical image analysis.

Proposed method

  • Proposes a new loss function that enforces hierarchical decomposition by minimizing reconstruction error for high-level and low-level components separately, plus a mutual information regularization term.
  • Introduces a conditional hierarchical VAE architecture where the low-level decoder is conditioned on both the high-level latent code and the low-level code, promoting disentanglement.
  • Uses a shared encoder backbone for high- and low-level features, with separate decoders for coarse and fine structure reconstruction.
  • Applies a modified variational inference objective with three reconstruction terms: high-level, low-level, and a cross-term enforcing independence between components.
  • Employs reparameterization and Monte Carlo sampling to enable end-to-end training of the hierarchical model.
  • Incorporates a KL divergence term for each latent space to regularize posterior distributions toward standard normal.

Experimental results

Research questions

  • RQ1Can a hierarchical VAE architecture with a dedicated low-level reconstruction branch improve image reconstruction sharpness compared to standard VAEs?
  • RQ2Does enforcing disentanglement between high-level and low-level features enhance the model's ability to reconstruct fine-grained textures in medical images?
  • RQ3Does the proposed pchVAE maintain or improve out-of-distribution (OoD) detection performance compared to baseline VAEs?
  • RQ4Can the model effectively separate coarse structural components from fine-textural details in brain MRI data?
  • RQ5Is the mutual information regularization term effective in promoting independence between high- and low-level components?

Key findings

  • The pchVAE achieves significantly sharper image reconstructions than standard VAEs and VQVAE-2, particularly in preserving fine details and textures in brain MRI slices.
  • The model maintains or slightly improves OoD detection performance, as measured by AUROC and average precision, indicating robust modeling of the data distribution.
  • The pchVAE outperforms the High VAE and Low VAE variants in reconstruction quality, demonstrating the benefit of joint modeling of both components.
  • The inclusion of the mutual information regularization term (λ₃) leads to more disentangled representations, with low-level components being less influenced by high-level features.
  • Despite higher computational cost, the pchVAE achieves better reconstruction fidelity without compromising generalization, as evidenced by consistent performance across HCP and BraTS2017 datasets.
  • The ablation study confirms that the three-term reconstruction loss is essential for achieving improved visual quality and disentanglement.