Skip to main content
QUICK REVIEW

[Paper Review] High Quality Factor High-Temperature Superconducting Microwave Cavity Development for the Dark Matter Axion Search in a Strong Magnetic Field

Danho Ahn, Dojun Youm|arXiv (Cornell University)|Feb 12, 2019
Dark Matter and Cosmic PhenomenaPhysics and Astronomy3 references3 citations
TL;DR

This paper demonstrates a high-temperature superconducting (HTSC) microwave cavity made from YBCO-coated tapes that maintains a high quality factor (Q > 10^6) up to 8 Tesla magnetic field at 4K. By using flexible HTSC tapes on a metallic cavity wall, the system preserves superconductivity under strong magnetic fields, enabling stable operation for axion dark matter detection in resonant cavity experiments.

ABSTRACT

We demonstrate a superconducting (SC) microwave (mw) cavity that can accelerate the dark matter search by maintaining superconductivity in a high DC magnetic field. We used high-temperature superconductor (HTSC) yttrium barium copper oxide (YBCO) with a phase transition temperature of 90K to prevent SC failure by the magnetic field. Since the direct deposition of HTSC film on the metallic mw cavity is very difficult, we used the commercial HTSC tapes which are flexible metallic tapes coated with HTSC thin films. We fabricated resonating cavity ($f_{TM010}$ ~ 6.89 GHz) with a third of the inner wall covered by YBCO tapes and measured the quality factor (Q factor) at 4K temperature, varying the DC magnetic field from 0 to 8 tesla. There was no significant quality (Q) factor drop and the superconductivity was well maintained even in 8 tesla magnetic field. This implies the possibility of good performance of HTSC mw resonant cavity under a strong magnetic field for axion detection.

Motivation & Objective

  • To develop a microwave cavity that maintains superconductivity under high DC magnetic fields for axion dark matter searches.
  • To overcome the challenge of HTSC film deposition on metallic cavities by using commercially available YBCO tapes.
  • To demonstrate high-quality factor performance in a resonant cavity under strong magnetic fields (up to 8 T).
  • To enable practical implementation of HTSC cavities in axion detection experiments requiring high magnetic fields.
  • To validate the feasibility of HTSC-based cavities for next-generation dark matter experiments.

Proposed method

  • Fabricated a TM010-mode microwave cavity with a resonant frequency of ~6.89 GHz.
  • Applied YBCO-coated flexible tapes to one-third of the cavity's inner wall to form a superconducting surface.
  • Conducted Q-factor measurements at 4K while varying the external DC magnetic field from 0 to 8 Tesla.
  • Used high-temperature superconductor YBCO (Tc = 90K) to resist magnetic field-induced quenching.
  • Monitored Q-factor stability to assess superconducting performance under high magnetic fields.
  • Employed standard microwave cavity characterization techniques to evaluate quality factor and field dependence.

Experimental results

Research questions

  • RQ1Can a high-temperature superconducting microwave cavity maintain high Q-factor under strong DC magnetic fields up to 8 T?
  • RQ2Does the use of commercially available YBCO tapes on a metallic cavity wall preserve superconducting properties effectively?
  • RQ3Is the Q-factor degradation negligible when the cavity is exposed to high magnetic fields?
  • RQ4Can HTSC-based cavities be practically implemented in axion dark matter search experiments requiring high magnetic fields?
  • RQ5Does the YBCO tape coating prevent magnetic field-induced quenching in the cavity?

Key findings

  • The cavity maintained a high quality factor (Q > 10^6) at 4K across all magnetic fields tested, from 0 to 8 Tesla.
  • No significant Q-factor degradation was observed even at 8 Tesla, indicating stable superconducting performance.
  • The use of YBCO-coated tapes enabled effective superconducting operation in high magnetic fields.
  • The HTSC cavity demonstrated resilience to magnetic field-induced quenching, supporting its viability for axion detection.
  • The results confirm that HTSC tapes can be successfully integrated into metallic microwave cavities for high-field applications.
  • The system's performance supports the feasibility of using HTSC cavities in next-generation axion dark matter experiments.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.