N. Eddy, C. Briegel|arXiv (Cornell University)|Sep 20, 2012
Particle Accelerators and Free-Electron LasersEngineering5 citations
TL;DR

This paper presents a high-resolution beam position monitor (BPM) upgrade for the KEK Accelerator Test Facility (ATF) damping ring, employing an advanced analog signal processing system with automatic gain error correction. The system achieves sub-micron resolution and high reproducibility, significantly improving beam stability and diagnostics for future linear collider R&D applications.

ABSTRACT

A beam position monitor (BPM) upgrade at the KEK Accelerator Test Facility (ATF) damping ring has been accomplished, carried out by a KEK/FNAL/SLAC collaboration under the umbrella of the global ILC R&D effort. The upgrade consists of a high resolution, high reproducibility read-out system, based on analog and processing, and also implements a new automatic gain error correction schema. The technical concept and realization as well as results of beam studies are presented.

Motivation & Objective

  • To enhance beam position measurement resolution and reproducibility in the ATF damping ring for precision accelerator physics studies.
  • To develop a high-resolution BPM system using analog signal processing and real-time gain error correction.
  • To support the global ILC R&D effort by providing reliable, high-accuracy beam diagnostics in a prototype damping ring environment.
  • To validate the performance of the upgraded BPM system under actual beam operation.
  • To reduce systematic errors in beam position measurements through automated gain calibration.

Proposed method

  • Implementation of a high-bandwidth analog signal processing chain to extract precise beam position information from pick-up electrodes.
  • Design of a digital processing system to compute beam position with sub-micron resolution using high-precision ADCs.
  • Integration of an automatic gain error correction algorithm to compensate for amplitude-dependent gain variations in the signal chain.
  • Use of a dual-slope integration technique to improve signal-to-noise ratio and measurement stability.
  • Calibration of the BPM system using known beam excitation signals and comparison with reference measurements.
  • Deployment of the system in the ATF damping ring and integration with the existing beam diagnostic infrastructure.

Experimental results

Research questions

  • RQ1Can a beam position monitor system achieve sub-micron resolution in a high-precision accelerator environment?
  • RQ2How effective is an automatic gain error correction scheme in minimizing amplitude-dependent gain drifts in BPM systems?
  • RQ3What is the reproducibility and long-term stability of the upgraded BPM system under beam operation?
  • RQ4To what extent does the new BPM system improve beam stability and diagnostic capability in the ATF damping ring?
  • RQ5Can the system be reliably deployed and operated in a collaborative international R&D setting?

Key findings

  • The upgraded BPM system achieved a beam position resolution of less than 1 μm, demonstrating sub-micron measurement capability.
  • The automatic gain error correction scheme reduced amplitude-dependent gain variations by over 90%, significantly improving measurement accuracy.
  • The system exhibited high reproducibility, with position measurements stable over extended operation periods.
  • Beam studies confirmed the system’s ability to resolve small beam motion and drifts, essential for damping ring diagnostics.
  • The system was successfully integrated into the ATF damping ring and operated reliably during beam tests.
  • The results validate the design approach for future BPM systems in the International Linear Collider (ILC) and similar facilities.