TL;DR

This paper proposes a bandpass filtering-based deep neural network architecture for highly scalable MRI reconstruction from highly subsampled k-space data. By applying convolutional networks directly in the k-space domain with localized patch processing and enforcing data consistency via the imaging model, the method achieves fast, accurate reconstructions that preserve measured data while enabling parallelization and scalability across multi-dimensional MRI datasets.

ABSTRACT

To increase the flexibility and scalability of deep neural networks for image reconstruction, a framework is proposed based on bandpass filtering. For many applications, sensing measurements are performed indirectly. For example, in magnetic resonance imaging, data are sampled in the frequency domain. The introduction of bandpass filtering enables leveraging known imaging physics while ensuring that the final reconstruction is consistent with actual measurements to maintain reconstruction accuracy. We demonstrate this flexible architecture for reconstructing subsampled datasets of MRI scans. The resulting high subsampling rates increase the speed of MRI acquisitions and enable the visualization rapid hemodynamics.

Motivation & Objective

  • Address the limitations of conventional CNNs in MRI reconstruction, particularly the lack of data consistency and poor scalability when measurements are in the k-space domain.
  • Overcome the challenge of training and inference on fixed image dimensions by operating directly in the measurement (k-space) domain with localized patches.
  • Enable efficient, parallelizable training and inference by decoupling reconstruction into independent k-space patches while preserving global data consistency.
  • Maintain high reconstruction accuracy even at high subsampling factors (>8×) by integrating the physical imaging model into the network architecture.
  • Provide a flexible framework adaptable to various MRI acquisition techniques, including non-Cartesian and wave-encoded sampling trajectories.

Proposed method

  • The method processes localized patches of k-space data directly in the frequency domain, avoiding transformation to the image domain during network inference.
  • A deep convolutional neural network (ConvNet) is trained to predict fully sampled k-space patches from their corresponding subsampled inputs, using the imaging model (including coil sensitivity maps) as an inductive bias.
  • The network output is inserted back into the full k-space reconstruction, ensuring that the final image is consistent with the original measured data through a data consistency step.
  • The architecture supports parallelization by treating each k-space patch independently, significantly reducing memory and computational bottlenecks.
  • The imaging model is incorporated via the adjoint operator Aᴴ, allowing the network to learn from the physical acquisition process while maintaining flexibility.
  • The method preserves the number of complex data channels in the input and output, enabling direct replacement of estimated samples with original measurements to enforce data fidelity.

Experimental results

Research questions

  • RQ1Can a deep neural network architecture be designed to operate directly in the k-space domain while maintaining data consistency with measured MRI acquisitions?
  • RQ2How does patch-based processing in the measurement domain improve scalability and parallelization in deep learning-based MRI reconstruction?
  • RQ3To what extent can a single, shared ConvNet generalize across diverse k-space regions without explicit modeling of frequency band-specific features?
  • RQ4Can the proposed bandpass network achieve reconstruction accuracy comparable to compressed sensing while being significantly faster and more scalable?
  • RQ5How well does the method generalize to non-Cartesian sampling trajectories, such as wave-encoded imaging, without requiring major architectural changes?

Key findings

  • The bandpass network achieved image reconstruction quality comparable to state-of-the-art compressed sensing methods, particularly in recovering fine anatomical details and image sharpness.
  • The method successfully reconstructed 2D T2-weighted abdominal MRI scans from wave-encoded, highly subsampled k-space data (subsampling factor of 3.2), with visual quality matching the compressed-sensing ground truth.
  • The network preserved data consistency by ensuring that the final reconstructed image matched the original measured k-space samples, preventing deviation from actual acquisitions.
  • The architecture enabled efficient, parallelized inference by processing independent k-space patches, significantly improving computational scalability over conventional patch-based image-domain networks.
  • The model demonstrated robustness to noise and artifacts, with enhanced recovery of fine structures highlighted in enlarged image regions (e.g., arrows in Fig. 10).
  • The framework was adaptable to non-Cartesian sampling by modifying the imaging model operator to include gridding, showing potential for broader application beyond Cartesian trajectories.