[Paper Review] Historical building stability monitoring by means of a cosmic ray tracking system
This paper proposes a cosmic ray muon tracking system for non-invasive, long-term stability monitoring of historical buildings, using muon scattering to detect millimeter-scale displacements over months to years. The method employs scintillating fiber detectors with silicon photomultipliers (SiPMs) and Monte Carlo simulations to demonstrate sub-millimeter precision in monitoring the wooden vaulted roof of Brescia's Palazzo della Loggia, proving feasible for slow deformation phenomena.
Cosmic ray radiation is mostly composed, at sea level, by high energy muons, which are highly penetrating particles capable of crossing kilometers of rock. Cosmic ray radiation constituted the first source of projectiles used to investigate the intimate structure of matter and is currently and largely used for particle detector test and calibration. The ubiquitous and steady presence at the Earth's surface and the high penetration capability has motivated the use of cosmic ray radiation also in fields beyond particle physics, from geological and archaeological studies to industrial applications and civil security. In the present paper, cosmic ray muon detection techniques are assessed for stability monitoring applications in the field of civil engineering, in particular for static monitoring of historical buildings, where conservation constraints are more severe and the time evolution of the deformation phenomena under study may be of the order of months or years. As a significant case study, the monitoring of the wooden vaulted roof of the "Palazzo della Loggia" in the town of Brescia, in Italy, has been considered. The feasibility as well as the performances and limitations of a monitoring system based on cosmic ray tracking, in the considered case, have been studied by Monte Carlo simulation and discussed in comparison with more traditional monitoring systems. Requirements for muon detectors suitable for this particular application, as well as the results of some preliminary tests on a muon detector prototype based on scintillating fibers and silicon photomultipliers SiPM are presented.
Motivation & Objective
- To develop a non-invasive, long-term monitoring system for historical buildings where traditional optical methods are obstructed by structural elements.
- To assess the feasibility of using cosmic ray muons for detecting millimeter-scale displacements in civil engineering structures.
- To evaluate the performance of a muon tracking system based on scintillating fibers and SiPMs in real-world conditions typical of historical buildings.
- To compare the proposed muon-based system with traditional mechanical monitoring techniques in terms of precision, installation constraints, and data acquisition time.
Proposed method
- A muon telescope composed of three axially aligned scintillating fiber detector modules (40 cm × 36 cm × 6 mm) with orthogonal layers is used as a fixed reference system.
- A muon target, identical in size and composition, is placed on the structure to be monitored, enabling relative position tracking.
- The system measures muon trajectories both upstream and downstream to calculate angular scattering, which correlates with material thickness and density.
- Monte Carlo simulations using the GEANT4 toolkit model the full geometry of the Palazzo della Loggia, including a 15 cm thick wooden ceiling, to simulate muon interactions and scattering.
- Statistical inference is applied to large event samples to extract position uncertainties, with precision evaluated as a function of data-taking time.
- Detector performance is optimized by adjusting geometrical parameters and improving data analysis techniques to enhance efficiency by factors of 2–3.
Experimental results
Research questions
- RQ1Can cosmic ray muon tracking detect millimeter-scale displacements in historical buildings over time scales of months to years?
- RQ2How does the presence of thick, obstructing materials like wooden ceilings affect the measurement precision of a muon-based monitoring system?
- RQ3To what extent can data analysis improvements and geometric optimization enhance the system's efficiency and reduce required data-taking time?
- RQ4How does the muon tracking system compare in precision and practicality to traditional laser and theodolite-based monitoring in obstructed, non-visible configurations?
- RQ5What detector configuration and technology (e.g., scintillating fibers with SiPMs) are most suitable for long-term, low-invasiveness structural monitoring?
Key findings
- The proposed muon tracking system achieved position measurement uncertainties of less than 1.0 mm for displacements observed in the Palazzo della Loggia, consistent with the time scale of the deformation phenomena.
- Data-taking times were found to be compatible with the slow evolution of structural deformations, making the method suitable for long-term monitoring.
- System efficiency can be improved by a factor of 2 to 3 through enhanced data analysis techniques without changing hardware.
- Geometric modifications to the detector layout can further improve performance, indicating design flexibility for various building configurations.
- The use of scintillating fibers with SiPMs offers a robust, low-cost, and reliable solution suitable for long-term deployment in historical buildings.
- Monte Carlo simulations confirmed that the method is viable for global, simultaneous monitoring of multiple structural points relative to a single reference system.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.