Skip to main content
QUICK REVIEW

[Paper Review] How Well Do Supervised 3D Models Transfer to Medical Imaging Tasks?

Wenxuan Li, Alan Yuille|ArXiv.org|Jan 20, 2025
Medical Imaging and AnalysisEngineering3 citations
TL;DR

The authors build AbdomenAtlas 1.1 with 9,262 annotated CT volumes and SuPreM supervised pre-trained models, demonstrating that supervised 3D pre-training yields superior and more data-efficient transfer to 3D medical segmentation than self-supervised pre-training, with strong cross-dataset generalization.

ABSTRACT

The pre-training and fine-tuning paradigm has become prominent in transfer learning. For example, if the model is pre-trained on ImageNet and then fine-tuned to PASCAL, it can significantly outperform that trained on PASCAL from scratch. While ImageNet pre-training has shown enormous success, it is formed in 2D, and the learned features are for classification tasks; when transferring to more diverse tasks, like 3D image segmentation, its performance is inevitably compromised due to the deviation from the original ImageNet context. A significant challenge lies in the lack of large, annotated 3D datasets rivaling the scale of ImageNet for model pre-training. To overcome this challenge, we make two contributions. Firstly, we construct AbdomenAtlas 1.1 that comprises 9,262 three-dimensional computed tomography (CT) volumes with high-quality, per-voxel annotations of 25 anatomical structures and pseudo annotations of seven tumor types. Secondly, we develop a suite of models that are pre-trained on our AbdomenAtlas 1.1 for transfer learning. Our preliminary analyses indicate that the model trained only with 21 CT volumes, 672 masks, and 40 GPU hours has a transfer learning ability similar to the model trained with 5,050 (unlabeled) CT volumes and 1,152 GPU hours. More importantly, the transfer learning ability of supervised models can further scale up with larger annotated datasets, achieving significantly better performance than preexisting pre-trained models, irrespective of their pre-training methodologies or data sources. We hope this study can facilitate collective efforts in constructing larger 3D medical datasets and more releases of supervised pre-trained models.

Motivation & Objective

  • Address the lack of large-scale annotated 3D datasets for transfer learning in medical imaging.
  • Evaluate whether supervised pre-training on 3D data transfers better to segmentation tasks than self-supervised approaches.
  • Create AbdomenAtlas 1.1 and release SuPreM to enable efficient, effective 3D transfer learning.
  • Demonstrate data/computation efficiency and generalization of supervised pre-trained models across external datasets and novel classes.

Proposed method

  • Construct AbdomenAtlas 1.1 with 9,262 CT volumes, 251,323 masks, spanning 25 anatomical structures and 7 tumor types, from 88 hospitals.
  • Annotate volumes via interactive, semi-automatic, human-in-the-loop pipeline to ensure high-quality per-voxel labels.
  • Train SuPreM, a suite of supervised pre-trained models (CNN and Transformer backbones) on AbdomenAtlas 1.1 for transfer learning.
  • Evaluate transfer performance on TotalSegmentator v1 and a proprietary dataset, comparing to learning-from-scratch and existing pre-trained models.
  • Assess data efficiency by varying pre-training data sizes and measuring transfer on target tasks; assess annotation/fine-tuning efficiency.
  • Test cross-domain generalization by direct inference on external datasets (OOD) and fine-tuning on novel classes.

Experimental results

Research questions

  • RQ1How well do supervised 3D pre-trained models transfer to 3D medical segmentation tasks compared with self-supervised pre-training?
  • RQ2What data and computational efficiencies are gained by supervised pre-training on a large annotated 3D dataset?
  • RQ3Do supervised pre-trained models generalize to external datasets (OOD) without fine-tuning?
  • RQ4Can SuPreM transfer to novel classes and tasks with limited annotated data?

Key findings

  • SuPreM achieves superior transfer performance on TotalSegmentator and a proprietary dataset compared with learning-from-scratch and existing pre-trained models.
  • Supervised pre-training is markedly more data- and computation-efficient: about 99.6% fewer data and 96.5% less computation for pre-training when comparing low-data/small-scale setups to larger baselines.
  • A model trained with 21 CT volumes, 672 masks, and 40 GPU hours showed transfer ability similar to a model trained with 5,050 volumes and 1,152 GPU hours.
  • In few-shot/low-data settings, SuPreM outperforms self-supervised models; fine-tuning on target tasks requires fewer annotated volumes and converges faster.
  • Direct inference of SuPreM on external datasets (OOD) yielded comparable or superior performance to IID baselines, indicating strong cross-dataset generalization.
  • Fine-tuning SuPreM on novel classes (e.g., additional muscles, cardiac structures, vertebrae, and pancreatic tumor types) outperformed self-supervised pre-training, supporting the advantage of same-task (segmentation) pre-training for novel-class transfer.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.