[Paper Review] Human Electromagnetic Field Exposure in Wearable Communications: A Review
This paper reviews human electromagnetic field (EMF) exposure from commercial wearable devices, focusing on specific absorption rate (SAR) at 2.4 GHz and 60 GHz. It analyzes SAR levels in off-the-shelf products, evaluates measurement standards, and finds that 60 GHz wearables can exceed ICNIRP and FCC SAR guidelines, requiring minimum separation distances of 12 mm (ICNIRP) and 15 mm (FCC) to ensure safety.
The concern on human health is often overseen while wearable technologies attract exploding interests. Mainly due to the extreme proximity or a direct physical contact to the human skin, wearable communications devices are acknowledged to cause higher levels of specific absorption rate (SAR) at the skin surface. Unfortunately, so far, we have found no study encompassing all the aspects that the general public needs to understand about wearable technologies--i.e., the analytical and experimental backgrounds, and report of SAR levels generated from commercial wearable devices. In this context, this paper provides an extensive review on SAR from various commercial wearable devices that are currently sold in the market, as well as the analytical framework and the current measurement methodologies for standard compliance tests. Moreover, considering the present interest in millimeter wave (mmW), this paper sheds light on the SAR evaluated at 60 GHz and also compares the SAR to that measured at 2.4 GHz. We expect that this paper will be of value in informing the general public of the safety in using the currently sold wearable devices, and in igniting further study of the exact biological consequences from electromagnetic field (EMF) exposure due to wearable devices.
Motivation & Objective
- To address the lack of comprehensive studies on real-world SAR levels from commercially available wearable devices.
- To analyze the impact of millimeter-wave (mmW) frequencies, particularly 60 GHz, on human EMF exposure compared to traditional 2.4 GHz bands.
- To provide a detailed review of SAR measurement methodologies and compliance standards for wearable technology.
- To inform the public and guide manufacturers on safe design practices for wearable devices based on current safety guidelines.
- To evaluate the potential health risks associated with prolonged or high-intensity EMF exposure from on-body wearables, especially at higher frequencies.
Proposed method
- Conducted a literature review on SAR, EMF exposure, and standards for wearable devices.
- Collected SAR data from product datasheets and external sources for commercial wearables including Apple AirPod, Fitbit, Snap camera, and Apple Watch.
- Applied standard SAR calculation frameworks based on IEEE and ICNIRP guidelines to estimate SAR values where not publicly disclosed.
- Simulated and compared SAR distributions at 2.4 GHz and 60 GHz using microstrip patch and Yagi-Uda antenna models with directional radiation patterns.
- Evaluated SAR as a function of distance from the human body, focusing on skin surface exposure.
- Used time-averaged SAR formulations to assess compliance with ICNIRP and FCC safety limits.
Experimental results
Research questions
- RQ1What are the actual SAR levels emitted by currently marketed wearable devices such as Apple AirPod, Fitbit, Snap wearable camera, and Apple Watch?
- RQ2How does SAR at 60 GHz compare to SAR at 2.4 GHz in wearable communication systems?
- RQ3What are the minimum safe separation distances between wearable devices and the human body to comply with ICNIRP and FCC SAR guidelines?
- RQ4How do radiation patterns (omnidirectional vs. directive) at 2.4 GHz and 60 GHz affect localized SAR exposure on the skin?
- RQ5To what extent do higher transmit power and increased number of antenna directors at 60 GHz elevate human EMF exposure?
Key findings
- SAR levels from commercial wearables like Apple AirPod, Fitbit, and Apple Watch were investigated using product datasheets and standard SAR calculation models.
- At 2.4 GHz, SAR values remain well below ICNIRP and FCC safety limits across all tested distances.
- At 60 GHz, SAR levels exceed both ICNIRP and FCC guidelines when the device is in close proximity to the skin.
- A minimum separation distance of 12 mm is required to comply with ICNIRP guidelines for 60 GHz wearable devices.
- A minimum separation distance of 15 mm is required to comply with FCC guidelines for 60 GHz wearable devices.
- The use of highly directive radiation patterns at 60 GHz, such as those in Yagi-Uda antennas, increases localized SAR on the skin surface due to focused energy exposure.