[Paper Review] ICD Coding from Clinical Text Using Multi-Filter Residual Convolutional Neural Network
This paper proposes MultiResCNN, a deep learning model that combines multi-filter and residual convolutional layers to improve ICD coding from clinical text. By capturing diverse text patterns and expanding the receptive field, the model achieves state-of-the-art performance on MIMIC-III and MIMIC-II datasets, outperforming prior models in 14 out of 15 evaluation metrics across multiple settings.
Automated ICD coding, which assigns the International Classification of Disease codes to patient visits, has attracted much research attention since it can save time and labor for billing. The previous state-of-the-art model utilized one convolutional layer to build document representations for predicting ICD codes. However, the lengths and grammar of text fragments, which are closely related to ICD coding, vary a lot in different documents. Therefore, a flat and fixed-length convolutional architecture may not be capable of learning good document representations. In this paper, we proposed a Multi-Filter Residual Convolutional Neural Network (MultiResCNN) for ICD coding. The innovations of our model are two-folds: it utilizes a multi-filter convolutional layer to capture various text patterns with different lengths and a residual convolutional layer to enlarge the receptive field. We evaluated the effectiveness of our model on the widely-used MIMIC dataset. On the full code set of MIMIC-III, our model outperformed the state-of-the-art model in 4 out of 6 evaluation metrics. On the top-50 code set of MIMIC-III and the full code set of MIMIC-II, our model outperformed all the existing and state-of-the-art models in all evaluation metrics. The code is available at https://github.com/foxlf823/Multi-Filter-Residual-Convolutional-Neural-Network.
Motivation & Objective
- To address the limitations of flat, fixed-length convolutional architectures in learning effective document representations for ICD coding.
- To improve ICD coding performance by capturing diverse text patterns across varying lengths and grammatical structures in clinical notes.
- To enhance model depth and representational capacity through residual connections and multi-scale filtering.
- To evaluate the model on widely used MIMIC datasets and compare it against state-of-the-art baselines.
- To demonstrate that deep, diversified text representations significantly improve ICD code prediction accuracy.
Proposed method
- The model uses pre-trained word2vec embeddings as input to capture semantic meaning in clinical text.
- A multi-filter convolutional layer applies multiple filter sizes (e.g., 3, 4, 5) to extract local patterns of varying lengths simultaneously.
- Residual blocks are stacked to enable deeper network architectures and mitigate vanishing gradient issues.
- The residual convolutional layer increases the receptive field, allowing the model to capture long-range dependencies in text.
- An attention layer is applied after the convolutional layers to highlight important tokens for code prediction.
- The output layer uses sigmoid activation to predict the probability of each ICD code independently, enabling multi-label classification.
Experimental results
Research questions
- RQ1Can a multi-filter convolutional layer improve ICD coding by capturing text patterns of varying lengths?
- RQ2Does incorporating residual connections into the CNN architecture enhance performance through deeper and more stable learning?
- RQ3How does the proposed MultiResCNN model compare to state-of-the-art models in multi-label ICD coding tasks?
- RQ4What is the impact of receptive field expansion on ICD code prediction in clinical text?
- RQ5To what extent do hyperparameters such as filter size and residual block count affect model performance?
Key findings
- On the full code set of MIMIC-III, MultiResCNN outperformed the state-of-the-art model in 4 out of 6 evaluation metrics, including macro-AUC, micro-F1, and precision at K=8 and K=15.
- On the top-50 code set of MIMIC-III and the full code set of MIMIC-II, MultiResCNN outperformed all existing and state-of-the-art models in all evaluation metrics.
- The model achieved a micro-F1 of 0.566 on MIMIC-III (full codes) and a precision@5 of 0.741, with minimal performance degradation when input length was truncated to 2,500 tokens.
- Hyperparameter tuning confirmed that both multi-filter and residual convolutional layers significantly improved performance, with the model converging in only 26 epochs compared to 85 for CAML.
- Despite a 1.9× increase in parameters and 2.3× longer training time per epoch, MultiResCNN achieved faster inference speed than CAML in some settings, though overall computational cost was higher.
- The model outperformed Perotte et al.'s SVM baseline by 0.171 in micro-F1 and Baumel et al.'s GRU-attention model by 0.098 in micro-F1 on MIMIC-II.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.