TL;DR

This paper proposes a high-resolution coherence factor (HRCF) weighting technique for linear-array photoacoustic imaging that replaces the conventional delay-and-sum (DAS) beamformer in the coherence factor formula with minimum variance (MV) beamforming. The method achieves superior image quality by significantly improving resolution and reducing sidelobes, with quantitative results showing up to 91% narrower full-width-half-maximum and 40% higher signal-to-noise ratio compared to DAS+CF at 40 mm depth.

ABSTRACT

In Photoacoustic imaging (PAI), the most prevalent beamforming algorithm is delay-and-sum (DAS) due to its simple implementation. However, it results in a low quality image affected by the high level of sidelobes. Coherence factor (CF) can be used to address the sidelobes in the reconstructed images by DAS, but the resolution improvement is not good enough compared to the high resolution beamformers such as minimum variance (MV). As a weighting algorithm in linear-array PAI, it was proposed to use high-resolution-CF (HRCF) weighting technique in which MV is used instead of the existing DAS in the formula of the conventional CF. The higher performance of HRCF was proved numerically and experimentally. The quantitative results obtained with the simulations show that at the depth of 40 mm, in comparison with DAS+CF and MV+CF, HRCF improves the full-width-half-maximum of about 91 % and 15 % and the signal-to-noise ratio about 40 % and 14 %, respectively. Moreover, the contrast ratio at the depth of 20 mm has been improved about 62 % and 21 % by HRCF, compared to DAS+CF and MV+CF, respectively

Motivation & Objective

  • To address the limitations of delay-and-sum (DAS) beamforming in photoacoustic imaging, which produces low-resolution images with high sidelobe levels.
  • To improve image quality beyond conventional coherence factor (CF) weighting, which fails to enhance resolution despite reducing sidelobes.
  • To develop a novel weighting technique that leverages the high-resolution performance of minimum variance (MV) beamforming within the CF framework.
  • To validate the proposed high-resolution coherence factor (HRCF) method through numerical simulations and experimental phantoms.

Proposed method

  • The HRCF method replaces the DAS beamformer output in the numerator of the conventional coherence factor (CF) formula with the output of a minimum variance (MV) beamformer.
  • The coherence factor is computed as the ratio of the MV beamformer output to the sum of absolute values of all element signals, enhancing signal-to-noise and resolution.
  • The resulting HRCF weight is applied to DAS beamformed signals to produce a final image with improved resolution and reduced sidelobes.
  • The method is evaluated using both simulated data with a 128-element linear array and experimental data from a tissue-mimicking phantom with microvessels.
  • The HRCF weighting is applied after DAS beamforming, combining the robustness of DAS with the resolution of MV.
  • The computational complexity increases from O(M) to O(L³) due to the MV computation in the HRCF numerator.

Experimental results

Research questions

  • RQ1Can replacing DAS with MV in the coherence factor formula significantly improve image resolution and sidelobe suppression in linear-array photoacoustic imaging?
  • RQ2How does the performance of HRCF compare to DAS+CF and MV+CF in terms of full-width-half-maximum (FWHM), signal-to-noise ratio (SNR), and contrast ratio?
  • RQ3Does HRCF maintain robustness under noisy conditions and errors in sound velocity estimation?
  • RQ4Can HRCF effectively enhance image quality in experimental settings with real tissue-mimicking phantoms?
  • RQ5What is the trade-off between image quality improvement and computational complexity in HRCF?

Key findings

  • At a depth of 40 mm, HRCF reduces the full-width-half-maximum (FWHM) by approximately 91% compared to DAS+CF and by 15% compared to MV+CF.
  • At 40 mm depth, HRCF improves the signal-to-noise ratio (SNR) by about 40% compared to DAS+CF and by 14% compared to MV+CF.
  • At 20 mm depth, HRCF improves the contrast ratio by approximately 62% compared to DAS+CF and by 21% compared to MV+CF.
  • In experimental imaging, HRCF produces sharper lateral profiles with reduced sidelobes and narrower mainlobes, as confirmed by lateral variation analysis at depths of 22 mm and 24 mm.
  • HRCF demonstrates higher robustness to noise and overestimated sound velocity, maintaining image quality under degraded signal conditions.
  • At a depth of 55 mm, HRCF improves SNR by 9 dB compared to DAS+CF and by 22 dB compared to MV+CF, while reducing FWHM by 1752 µm and 44 µm, respectively.