[Paper Review] Impact of Cold Noise on the tracking performance of ATLAS ITk short strip barrel modules using a charged particle beam
The paper investigates how Cold Noise affects tracking in ITk short-strip barrel modules, using two modules (one non-irradiated and one irradiated to end-of-life fluence) and beam tests to quantify single-strip and global performance under CN. It assesses operability, thresholds, and potential mitigation strategies.
The inner tracking system of the ATLAS experiment will be upgraded to a full silicon detector in 2030 for HL-LHC. The new tracking system is called ITk, the Inner Tracker. It is required to be operable with efficiency higher than 99\% and noise hit occupancy smaller than 0.1\%. During the pre-production phase of the ITk project, many short-strip modules were observed to exhibit so-called "Cold Noise (CN)", wherein clusters of strips displayed very high noise when the modules were operated at temperatures below~$-35\degree$C. To investigate the CN impact and ensure the quality of module production, huge amount of effort have been put in by the collaboration. This paper focuses on the impact of CN on the tracking performance by examining two short strip modules that exhibit CN: one is non-irradiated, while the other one has been irradiated to the maximum expected end-of-lifetime fluence. For each module, the global and single strip tracking performance are evaluated.
Motivation & Objective
- Assess whether ITk short-strip modules can meet >99% tracking efficiency and <0.1% hit noise occupancy under Cold Noise (CN).
- Characterize CN effects on both non-irradiated and irradiated modules at end-of-life fluence.
- Determine single-strip and global operating windows as CN varies across regions of the module.
- Evaluate how CN affects charge collection, efficiency threshold, and potential masking strategies for CN strips.
Proposed method
- Threshold scans on CN-affected strips in two short-strip modules (non-irradiated and irradiated to 1.1e15 n_eq/cm^2).
- Model single-strip efficiency as a function of charge threshold using a skewed complementary error function to extract Q50 and operating window width.
- Define Qc_no as the threshold for 10^-3 hit occupancy to quantify CN impact per strip.
- Compare CN regions (low/high CN) and normal regions to assess CN impact on efficiency and noise.
- Perform threshold scans at multiple beam positions and reconstruct tracks with the ADENIUM telescope, DESY II beam, and EUDAQ2/Corryvreckan software.
![Figure 1 : Exploded view of a short strip barrel module with all relevant components. Taken from [ 15 ] .](https://ar5iv.labs.arxiv.org/html/2601.05393/assets/fig/itk/itk_components.png)
Experimental results
Research questions
- RQ1How does Cold Noise alter the single-strip efficiency versus threshold in CN-affected regions for both non-irradiated and irradiated modules?
- RQ2What is the impact of CN on the global operability (efficiency >99% with noise occupancy <0.1%) of ITk short-strip modules over their lifetime, including end-of-life irradiation?
- RQ3Can CN strips be effectively masked or mitigated to preserve overall module performance?
- RQ4How does irradiation interact with CN to affect charge collection (Q50) and the feasible operating threshold?
- RQ5What mitigation approach (e.g., interposer layer) could restore CN-affected module performance to specification?
Key findings
- CN narrows the operating threshold window; non-irradiated strips can operate around 1 fC threshold, but irradiated strips fail to meet specs under CN.
- Charge collection is not significantly reduced by CN, but irradiation lowers the median collected charge (Q50) by up to ~60–70% compared to non-irradiated modules.
- In non-irradiated modules, less than 3% of CN regions fail the detector requirements; in irradiated modules, about 20% fail in low CN and ~52% fail in high CN regions.
- Operating window analyses show Qc_no < Qc_eff is needed for viable operation; irradiation reduces Qc_eff to below 0.5 fC, making CN-driven operation challenging.
- If CN-induced hit noise occupancy can be kept below 1% at thresholds above ~0.45 fC, roughly 60% of strips could meet lifetime requirements, suggesting feasible global performance in many regions.
- Approximately 60% of strips could meet operating requirements by end-of-life if CN occupancy is controlled, though some regions may not meet all constraints, especially after irradiation.
- An interposer solution (adding protective adhesive layers and a Kapton separator) shows promise in restoring CN-affected modules to specification according to initial test-beam results.

Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.