Skip to main content
QUICK REVIEW

[Paper Review] Improvement of the Standard Characterization Method on k33 Mode Piezoelectric Specimens

Yoonsang Park, Yuxuan Zhang|arXiv (Cornell University)|Dec 31, 2019
Acoustic Wave Resonator TechnologiesEngineering36 references22 citations
TL;DR

This paper proposes a partial electrode (PE) configuration to overcome critical flaws in the IEEE Standard k33 mode piezoelectric specimen, enabling direct and accurate determination of both extensive and intensive elastic properties and their losses. By using curve fitting on admittance spectra from PE-configured samples (open, short, and side electrodes), the method eliminates error propagation and electrical noise, yielding significantly reduced loss errors—especially for tan 𝜙′ and tan 𝜃′—and more reliable mechanical quality factors and coupling losses.

ABSTRACT

Even though standard method to determine physical parameters of piezoelectric materials has been set up for several decades, bare attention has been made on loss determination method. Furthermore, several deficits have been recognized in the standard method for k33 mode. In this study, detailed discussion on deficits of IEEE Standard k33 is investigated and the method to resolve such deficits will be introduced. The standard k33 specimen suffers from small capacitance, which causes huge experimental error, intrinsic electrical energy leakage, specimen setup issue and inability to directly determine intensive elastic properties. In order to resolve these issues, partial electrode method was introduced, and curve fitting was demonstrated to determine physical parameters and losses.

Motivation & Objective

  • To identify and resolve critical deficits in the IEEE Standard k33 mode piezoelectric specimen method.
  • To eliminate error propagation from indirect determination of intensive elastic compliance and loss factors.
  • To reduce experimental errors caused by low capacitance, electrical noise, and fringing fields in standard specimens.
  • To enable direct, accurate measurement of both extensive and intensive elastic, dielectric, and piezoelectric loss factors.
  • To improve the reliability of mechanical quality factor and coupling loss determination for high-power piezoelectric device design.

Proposed method

  • Proposed a partial electrode (PE) configuration with a 10% center electrode on k33 specimens to enhance capacitance and reduce measurement noise.
  • Used finite element analysis (FEA) with ATILA++ to model fringing field effects and validate electrode configuration.
  • Measured admittance/impedance spectra on five sample types: standard k33, k31, PE open circuit (OC), short circuit (SC), and side electrode (SE).
  • Applied curve fitting of experimental admittance data to analytical admittance equations for each PE configuration to extract physical parameters.
  • Used OC data to determine s33^D and tan 𝜙′′′, SE data for s33^E and tan 𝜙′, and SC data (from OC/SE) to determine d33 and tan 𝜃′.
  • Validated k33 values using two independent equations: k33² = d33² / (s33^E ε₀ ε33^X) and 1 - k33² = s33^D / s33^E, achieving consistency.

Experimental results

Research questions

  • RQ1Why does the IEEE Standard k33 method produce unreliable loss values, particularly for tan 𝜙′ and tan 𝜃′?
  • RQ2How do fringing electric fields and low capacitance in standard k33 specimens contribute to measurement errors?
  • RQ3Can a partial electrode configuration eliminate error propagation and improve direct determination of intensive elastic properties?
  • RQ4To what extent does the PE method reduce experimental noise and improve accuracy in loss factor measurement?
  • RQ5How do the k33 values derived from two independent equations compare when using the PE method?

Key findings

  • The PE method reduced the error in tan 𝜙′′′ (elastic loss) to less than 1% fitting error, compared to massive errors in standard k33 specimens.
  • The PE method yielded a tan 𝜃′ (piezoelectric loss) error of only 12%, compared to 480% in the standard k33 method due to error propagation.
  • The k33 value derived from two independent equations (24) and (25) agreed within 2.5% (71.7% vs. 69%), confirming methodological consistency.
  • The PE configuration increased capacitance at the center electrode, reducing electrical noise and enabling reliable measurement of small currents.
  • The FEA simulations confirmed a 7.4% overestimation of s33^D and 2.4% underestimation of k33 in standard specimens due to fringing fields.
  • The PE method enabled direct determination of s33^D, s33^E, d33, and all loss factors, eliminating cumulative errors from indirect calculations.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.