[Paper Review] Improving Automated COVID-19 Grading with Convolutional Neural Networks in Computed Tomography Scans: An Ablation Study
This study improves automated COVID-19 grading in CT scans by evaluating key components in 3D convolutional neural networks (CNNs), including 3D architecture, transfer learning, lesion map inputs, and continuous output prediction. The 3D CNN with transfer learning achieved an AUC of 0.934 on an internal test set and 0.923 on a public dataset, significantly outperforming prior 2D CNNs.
Amidst the ongoing pandemic, several studies have shown that COVID-19 classification and grading using computed tomography (CT) images can be automated with convolutional neural networks (CNNs). Many of these studies focused on reporting initial results of algorithms that were assembled from commonly used components. The choice of these components was often pragmatic rather than systematic. For instance, several studies used 2D CNNs even though these might not be optimal for handling 3D CT volumes. This paper identifies a variety of components that increase the performance of CNN-based algorithms for COVID-19 grading from CT images. We investigated the effectiveness of using a 3D CNN instead of a 2D CNN, of using transfer learning to initialize the network, of providing automatically computed lesion maps as additional network input, and of predicting a continuous instead of a categorical output. A 3D CNN with these components achieved an area under the ROC curve (AUC) of 0.934 on our test set of 105 CT scans and an AUC of 0.923 on a publicly available set of 742 CT scans, a substantial improvement in comparison with a previously published 2D CNN. An ablation study demonstrated that in addition to using a 3D CNN instead of a 2D CNN transfer learning contributed the most and continuous output contributed the least to improving the model performance.
Motivation & Objective
- To systematically evaluate components that improve automated COVID-19 grading in CT scans using deep learning.
- To compare the performance of 3D vs. 2D CNN architectures for classifying COVID-19 from thorax CT volumes.
- To assess the impact of transfer learning, lesion map inputs, and continuous output prediction on model performance.
- To enable fair benchmarking by validating models on a public dataset (iCTCF) and releasing an open grand challenge platform.
Proposed method
- Trained and compared 2D and 3D CNN architectures using the same internal dataset and public iCTCF dataset for fair comparison.
- Employed transfer learning by initializing models with ImageNet and Kinetics pre-trained weights to improve feature learning.
- Integrated automatically generated lesion segmentation maps as an additional input channel to the classification network.
- Evaluated both categorical (CO-RADS score) and continuous output regression heads for model prediction.
- Conducted an ablation study to isolate the contribution of each component to overall performance.
- Validated models on both an internal test set of 105 scans and a public external test set of 742 scans to assess generalization.
Experimental results
Research questions
- RQ1Does using a 3D CNN instead of a 2D CNN improve performance in automated COVID-19 grading from CT scans?
- RQ2To what extent does transfer learning from natural images and video data enhance model performance?
- RQ3How does adding lesion segmentation maps as input affect the classification accuracy of the model?
- RQ4What is the impact of predicting a continuous output score instead of a categorical CO-RADS class?
- RQ5How do these components affect model generalization across different datasets with varying slice thickness and definitions of positive cases?
Key findings
- The 3D CNN with transfer learning achieved an AUC of 0.934 on the internal test set and 0.923 on the public iCTCF dataset, significantly outperforming prior 2D CNNs.
- Transfer learning contributed the most to performance improvement, with the largest relative gain among all evaluated components.
- Using lesion maps as input did not yield a statistically significant performance increase on either test set, suggesting limited benefit for this approach.
- Replacing categorical output with continuous prediction contributed the least to performance gain, though it eliminated the need to define discrete CO-RADS thresholds.
- Performance degradation was observed on scans with slice thickness >1.5mm, particularly for the 3D model, indicating sensitivity to image resolution and reconstruction parameters.
- The ablation study confirmed that transfer learning and 3D architecture were consistently beneficial, while lesion maps and continuous output showed minimal or non-significant gains.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.