Skip to main content
QUICK REVIEW

[Paper Review] Improving Segmentation of Objects with Varying Sizes in Biomedical Images using Instance-wise and Center-of-Instance Segmentation Loss Function

Muhammad Febrian Rachmadi, Charissa Poon|arXiv (Cornell University)|Apr 13, 2023
Advanced Neural Network ApplicationsComputer Science6 citations
TL;DR

This paper proposes the Instance-wise and Center-of-Instance (ICI) loss, a novel compound loss function that improves segmentation of biomedical images with objects of varying sizes by combining instance-wise and center-of-instance regularization. It significantly outperforms Dice and blob losses, achieving a 2.7% average improvement in Dice similarity coefficient on stroke lesion segmentation tasks.

ABSTRACT

In this paper, we propose a novel two-component loss for biomedical image segmentation tasks called the Instance-wise and Center-of-Instance (ICI) loss, a loss function that addresses the instance imbalance problem commonly encountered when using pixel-wise loss functions such as the Dice loss. The Instance-wise component improves the detection of small instances or ``blobs" in image datasets with both large and small instances. The Center-of-Instance component improves the overall detection accuracy. We compared the ICI loss with two existing losses, the Dice loss and the blob loss, in the task of stroke lesion segmentation using the ATLAS R2.0 challenge dataset from MICCAI 2022. Compared to the other losses, the ICI loss provided a better balanced segmentation, and significantly outperformed the Dice loss with an improvement of $1.7-3.7\%$ and the blob loss by $0.6-5.0\%$ in terms of the Dice similarity coefficient on both validation and test set, suggesting that the ICI loss is a potential solution to the instance imbalance problem.

Motivation & Objective

  • Address the instance imbalance problem in biomedical image segmentation, where large objects dominate over small ones.
  • Improve detection of small, sparse instances (e.g., stroke lesions) in MRI scans with mixed-size objects.
  • Develop a loss function that combines instance-wise and center-of-instance supervision to enhance segmentation accuracy across object sizes.
  • Demonstrate the effectiveness of the ICI loss on a real-world challenge dataset (ATLAS R2.0) with clinical relevance.
  • Provide a robust, hyperparameter-tolerant loss that performs well without extensive tuning, especially in patch-based and whole-image inference.

Proposed method

  • Propose a two-component loss function: Instance-wise loss (L_instance) and Center-of-Instance loss (L_center), both computed per instance.
  • L_instance penalizes false positives and false negatives per instance by computing intersection-over-union (IoU) between predicted and ground-truth instance masks.
  • L_center enforces correct localization by computing IoU between the predicted center point and the true center of each instance.
  • Combine the two losses into a weighted sum: L_ICI = a·L_instance + b·L_center, where a, b are learnable or fixed hyperparameters.
  • Integrate the ICI loss as a regularizer with a base pixel-wise loss (e.g., Dice loss) to improve training stability and generalization.
  • Use connected component analysis (CCA) to identify individual instances from predicted segmentation maps for instance-level evaluation.

Experimental results

Research questions

  • RQ1Can a compound loss function that combines instance-wise and center-of-instance supervision improve segmentation of small and large objects simultaneously?
  • RQ2How does the ICI loss compare to standard pixel-wise losses (e.g., Dice) and instance-wise losses (e.g., blob loss) in handling instance imbalance in biomedical images?
  • RQ3Does the ICI loss maintain consistent performance across different input scales (whole image vs. patch-based inference) and test sets?
  • RQ4What is the impact of hyperparameter weighting (a, b, c) on the ICI loss performance, and can a simple default setting (e.g., a=b=c=1) achieve robust results?
  • RQ5Is the ICI loss effective in real-world clinical datasets with complex, variable-sized lesions like stroke lesions in MRI?

Key findings

  • The ICI loss improved the Dice similarity coefficient (DSC) by 1.7–3.7% compared to the Dice loss and 0.6–5.0% compared to the blob loss on both validation and test sets of the ATLAS R2.0 dataset.
  • On the test set, the ICI loss achieved a DSC of 0.5817 with a=1/4, b=1/2, c=1/4, outperforming the blob loss (0.5805) and Dice loss (0.5598) in mean DSC ranking.
  • The ICI loss achieved the best mean rank (1.75) on the test set, indicating superior overall segmentation quality across multiple metrics.
  • The ICI loss reduced lesion count errors and volume differences, with the best configuration (a=1, b=1, c=1) achieving the lowest lesion count error (4.78) and volume difference (11,564.10) on the test set.
  • A simple default weight setting (a=1, b=1, c=1) without hyperparameter tuning yielded consistent improvements across all evaluation metrics.
  • The ICI loss was robust to unseen test data, with consistent performance gains across both validation and test sets, suggesting strong generalization ability.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.