[Paper Review] Improving the Fairness of Chest X-ray Classifiers
This paper investigates fairness in chest X-ray classifiers by comparing group fairness and minimax fairness definitions, finding that simple data balancing outperforms complex debiasing methods, and that group fairness methods often degrade performance across all groups. The authors advocate for analyzing data bias origins over relying on algorithmic fixes.
Deep learning models have reached or surpassed human-level performance in the field of medical imaging, especially in disease diagnosis using chest x-rays. However, prior work has found that such classifiers can exhibit biases in the form of gaps in predictive performance across protected groups. In this paper, we question whether striving to achieve zero disparities in predictive performance (i.e. group fairness) is the appropriate fairness definition in the clinical setting, over minimax fairness, which focuses on maximizing the performance of the worst-case group. We benchmark the performance of nine methods in improving classifier fairness across these two definitions. We find, consistent with prior work on non-clinical data, that methods which strive to achieve better worst-group performance do not outperform simple data balancing. We also find that methods which achieve group fairness do so by worsening performance for all groups. In light of these results, we discuss the utility of fairness definitions in the clinical setting, advocating for an investigation of the bias-inducing mechanisms in the underlying data generating process whenever possible.
Motivation & Objective
- To evaluate whether group fairness or minimax fairness is more appropriate for clinical chest X-ray classifiers.
- To benchmark nine fairness methods on two public chest X-ray datasets (MIMIC-CXR and CheXpert) under both fairness definitions.
- To investigate whether debiasing methods improve worst-group performance without degrading overall performance.
- To explore the role of label bias in performance disparities, especially in 'No Finding' predictions.
- To provide recommendations for fair ML deployment in healthcare based on data origin analysis and performance evaluation across metrics.
Proposed method
- The authors train and evaluate deep learning models on MIMIC-CXR and CheXpert datasets using Empirical Risk Minimization (ERM) and Balanced-ERM.
- They apply nine fairness methods targeting group fairness (e.g., adversarial debiasing, reweighting) and minimax fairness (e.g., minimax optimization) to improve worst-group performance.
- A radiologist manually labels 1,200 MIMIC-CXR reports previously labeled as 'No Finding' by an automated NLP system to assess label quality.
- The study evaluates models across multiple metrics (TPR, FPR, calibration) and operating thresholds to assess fairness and performance.
- They compare performance across protected groups (e.g., sex, age) and analyze disparities in calibration and error rates.
- The authors use statistical tests to confirm significant performance gaps and assess whether debiasing methods reduce or exacerbate them.
Experimental results
Research questions
- RQ1Does minimizing disparity across protected groups (group fairness) lead to better worst-group performance than minimax fairness in chest X-ray classification?
- RQ2Do existing algorithmic debiasing methods improve fairness without degrading performance for any group?
- RQ3Is the performance gap in 'No Finding' predictions due to label bias in the automatic NLP labeling process?
- RQ4Can simple data balancing outperform complex fairness-aware training methods in clinical fairness benchmarks?
- RQ5Under what conditions should fairness be defined by minimizing worst-group performance versus equalizing error rates across groups?
Key findings
- Simple data balancing outperforms all nine fairness methods in improving worst-group performance, suggesting that data curation is more effective than algorithmic debiasing.
- Debiasing methods that achieve group fairness often worsen performance for all protected groups, indicating a trade-off between fairness and overall accuracy.
- Significant performance disparities exist in TPR and FPR across protected groups (e.g., Black females are underdiagnosed), even after debiasing.
- Label bias in automatically generated 'No Finding' labels from radiology reports contributes to performance gaps, especially in older age groups.
- Calibration errors differ across groups, implying that fixed operating thresholds may lead to unequal risk estimation in clinical deployment.
- The study finds no evidence that complex fairness algorithms improve fairness beyond basic data balancing, and highlights the importance of analyzing data generation mechanisms.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.