[Paper Review] In-flight calibration of the Hinode EIS. Preliminary results
This paper presents an in-flight radiometric calibration correction for the Hinode EIS spectrograph using the line ratio technique across quiet Sun, active regions, and flares from 2006–2012. The correction, applied to address time-dependent degradation—particularly a factor-of-two or greater drop in the long-wavelength (LW) channel responsivity by 2010—restores line ratios and He II 256 Å radiances to stability within 20%, resolving long-standing discrepancies in Fe X, Fe XIII, Fe XIV, Fe XVII, and Fe XXIV lines.
A preliminary assessment of the in-flight radiometric calibration of the Hinode EUV Imaging Spectrometer (EIS) is presented. This is done with the line ratio technique applied to a wide range of observations of the quiet Sun, active regions and flares from 2006 until 2012. The best diagnostic lines and the relevant atomic data are discussed in detail. Radiances over the quiet Sun are also considered, with comparisons with previous measurements. Some departures in the shapes of the ground calibration responsivities are found at the start of the mission. These shapes do not change significantly over time, with the exception of the shorter wavelengths of the EIS short-wavelength (SW) channel, which shows some degradation. The sensitivity of the SW channel at longer wavelengths does not show significant degradation, while that of the long-wavelength (LW) channel shows a significant degradation with time. By the beginning of 2010 the responsivity of the LW channel was already a factor of two or more lower than the values measured on the ground. A first-order correction is proposed. With this correction, the main ratios of lines in the two channels become constant to within a relative 20%, and the He II 256 A radiances over the quiet Sun also become constant over time. This correction removes long-standing discrepancies for a number of lines and ions, in particular those involving the strongest Fe X, Fe XIII, Fe XIV, Fe XVII, and Fe XXIV lines, where discrepancies of factors of more than two were found. These results have important implications for various EIS science analyses, in particular for measurements of temperatures, emission measures and elemental abundances.
Motivation & Objective
- To assess the in-flight radiometric calibration of the Hinode EUV Imaging Spectrometer (EIS) using solar observations.
- To identify and correct for time-dependent degradation in EIS responsivity, particularly in the long-wavelength (LW) and short-wavelength (SW) channels.
- To resolve persistent discrepancies in line ratios and radiances—especially for Fe X, Fe XIII, Fe XIV, Fe XVII, and Fe XXIV—observed in previous analyses.
- To ensure long-term consistency and accuracy of EIS measurements for solar physics studies involving temperature, emission measure, and elemental abundance determinations.
Proposed method
- Application of the line ratio technique to a wide dataset of quiet Sun, active region, and flare observations from 2006 to 2012.
- Use of well-established diagnostic lines and atomic data to evaluate calibration stability and identify responsivity deviations.
- Comparison of in-flight radiances, particularly He II 256 Å, with pre-launch ground calibration values to detect temporal degradation.
- Identification of wavelength-dependent degradation: significant in the SW channel at short wavelengths and in the LW channel across all wavelengths.
- Development of a first-order correction model to adjust the LW channel responsivity, restoring consistency in line ratios and radiances.
- Validation of the correction by verifying that key line ratios and He II 256 Å radiances remain constant over time within 20%.
Experimental results
Research questions
- RQ1How has the EIS instrument’s responsivity changed over time in the long-wavelength (LW) and short-wavelength (SW) channels since launch?
- RQ2To what extent do observed discrepancies in line ratios and radiances—especially for Fe X, Fe XIII, Fe XIV, Fe XVII, and Fe XXIV—arise from calibration drift rather than physical variability?
- RQ3Can a first-order correction be applied to the LW channel responsivity to restore temporal stability in EIS measurements?
- RQ4To what extent does the correction restore consistency in He II 256 Å radiances over the quiet Sun across the mission timeline?
- RQ5What is the impact of the correction on the reliability of EIS-derived physical parameters such as temperature, emission measure, and elemental abundances?
Key findings
- The long-wavelength (LW) channel responsivity degraded significantly over time, dropping by a factor of two or more by early 2010 compared to ground calibration values.
- The short-wavelength (SW) channel showed minor degradation only at the shortest wavelengths, with no significant change at longer SW wavelengths.
- A first-order correction was successfully applied to the LW channel responsivity, stabilizing key line ratios within 20% over time.
- After correction, He II 256 Å radiances over the quiet Sun remained constant over the mission duration, resolving a long-standing inconsistency.
- The correction eliminated discrepancies of more than a factor of two in the strongest lines of Fe X, Fe XIII, Fe XIV, Fe XVII, and Fe XXIV, which had previously hindered accurate abundance and temperature analysis.
- The corrected calibration enables reliable long-term analysis of solar plasma conditions, including temperature, emission measure, and elemental abundances, using EIS data.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.