[Paper Review] In Situ Translational Hand-Eye Calibration of Laser Profile Sensors using Arbitrary Objects
This paper presents a target-agnostic method for in situ translational hand-eye calibration of 2D laser profile sensors on robotic systems, using any arbitrary 2D or 3D object as a calibration target. Given a known rotation matrix, the method solves an over-determined linear system to estimate translation with sub-millimeter accuracy, validated experimentally on real robotic setups with both 2D and 3D targets.
Hand-eye calibration of laser profile sensors is the process of extracting the homogeneous transformation between the laser profile sensor frame and the end-effector frame of a robot in order to express the data extracted by the sensor in the robot's global coordinate system. For laser profile scanners this is a challenging procedure, as they provide data only in two dimensions and state-of-the-art calibration procedures require the use of specialised calibration targets. This paper presents a novel method to extract the translation-part of the hand-eye calibration matrix with rotation-part known a priori in a target-agnostic way. Our methodology is applicable to any 2D image or 3D object as a calibration target and can also be performed in situ in the final application. The method is experimentally validated on a real robot-sensor setup with 2D and 3D targets.
Motivation & Objective
- Address the challenge of hand-eye calibration for 2D laser profile sensors, which traditionally require specialized calibration artifacts.
- Overcome the limitations of existing methods that depend on custom, costly, or hard-to-manufacture calibration targets.
- Enable in situ calibration in real industrial workcells using any available object, reducing setup complexity and cost.
- Achieve high-accuracy translation estimation when the rotation component of the hand-eye matrix is known a priori.
- Demonstrate robustness to minor perturbations in prior rotation knowledge and improve accuracy with increasing number of point clouds.
Proposed method
- Formulate the hand-eye calibration problem as solving an over-determined linear system of the form Ax = b, where x represents the unknown translation vector.
- Use point cloud registration to estimate the position of the calibration target in the robot’s base frame for each robot pose.
- Leverage known rotation matrix ERS from mechanical mounting constraints, eliminating the need for rotation estimation.
- Construct the system matrix A and vector b from the relative transformations between the robot end-effector and the target’s registered point clouds.
- Apply least-squares optimization to solve for the translation vector that minimizes the error between predicted and observed laser profile positions.
- Enable in situ calibration by using any accessible 2D or 3D object with a known CAD model as the calibration target.
Experimental results
Research questions
- RQ1Can translational hand-eye calibration of laser profile sensors be performed without specialized calibration targets?
- RQ2How accurate is the proposed method when using arbitrary 2D or 3D calibration objects in real-world robotic setups?
- RQ3How does the accuracy of the translation estimation vary with perturbations in the known rotation matrix?
- RQ4What is the impact of the number of reconstructed point clouds on calibration accuracy?
- RQ5Can the method be applied in situ within industrial workcells using standard parts as calibration targets?
Key findings
- The method achieves sub-millimeter accuracy in translation estimation, with a mean error of 0.254 mm (±0.139 mm SD) for the 2D target and 0.701 mm (±0.135 mm SD) for the 3D target.
- For the 2D target, the calibration results show a mean error of 0.254 mm in x, 0.046 mm in y, and 0.049 mm in z, with high repeatability across five repeated datasets.
- For the 3D target, the mean error is higher (0.701 mm) due to trajectory-specific occlusion and registration errors, but remains within acceptable limits for industrial use.
- The method remains robust to small perturbations (up to 2°) in the known rotation matrix, with errors in translation remaining below 1 mm.
- Calibration accuracy improves significantly with more point clouds: mean error drops from 1.41 mm (3 clouds) to 0.196 mm (7 clouds).
- The method enables in situ calibration using any CAD-modelled object, eliminating dependency on custom calibration artifacts and simplifying deployment in real industrial environments.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.