[Paper Review] Indication as Prior Knowledge for Multimodal Disease Classification in Chest Radiographs with Transformers
This paper proposes a multimodal transformer model that leverages the clinical indication field—provided as free-text prior to imaging—as prior knowledge to improve chest X-ray disease classification. Fine-tuning a unimodal BERT model with image features from a ResNet-152, the method achieves 87.8% average micro AUROC on MIMIC-CXR, outperforming prior unimodal (84.4%) and multimodal (86.0%) approaches.
When a clinician refers a patient for an imaging exam, they include the reason (e.g. relevant patient history, suspected disease) in the scan request; this appears as the indication field in the radiology report. The interpretation and reporting of the image are substantially influenced by this request text, steering the radiologist to focus on particular aspects of the image. We use the indication field to drive better image classification, by taking a transformer network which is unimodally pre-trained on text (BERT) and fine-tuning it for multimodal classification of a dual image-text input. We evaluate the method on the MIMIC-CXR dataset, and present ablation studies to investigate the effect of the indication field on the classification performance. The experimental results show our approach achieves 87.8 average micro AUROC, outperforming the state-of-the-art methods for unimodal (84.4) and multimodal (86.0) classification. Our code is available at https://github.com/jacenkow/mmbt.
Motivation & Objective
- To improve multimodal chest X-ray classification by incorporating the indication field, a clinical text describing the reason for imaging.
- To evaluate whether unimodally pre-trained BERT can effectively learn multimodal interactions when fine-tuned with image features.
- To assess robustness of the model to common textual errors and missing indication fields.
- To establish a strong baseline for multimodal disease classification using only pre-existing, non-invasive clinical information.
Proposed method
- Fine-tune a unimodally pre-trained BERT model on dual image-text inputs, where the image is encoded via features from a ResNet-152 classifier.
- Use the indication field from radiology reports as a source of prior clinical knowledge to guide attention and improve classification.
- Apply a multimodal BERT (MMBT) architecture to jointly process image and text embeddings with cross-attention mechanisms.
- Train the model end-to-end on the MIMIC-CXR dataset with multi-label classification loss.
- Evaluate robustness using adversarial perturbations: character swaps, keyboard typos, synonym replacement, and missing/swap inputs.
- Use a late fusion strategy where image and text features are processed separately before fusion in the transformer encoder.

Experimental results
Research questions
- RQ1Can a unimodally pre-trained BERT model effectively learn multimodal interactions between chest X-ray images and clinical indication text?
- RQ2Does incorporating the indication field as prior knowledge improve classification performance compared to image-only or late-fusion baselines?
- RQ3How robust is the model to common textual errors such as typos, synonym usage, or missing indication fields?
- RQ4Does the model’s performance degrade significantly when given a conflicting indication from another patient?
- RQ5Can the model maintain performance when the indication field is absent, matching image-only baselines?
Key findings
- The proposed method achieves 87.8% average micro AUROC on the MIMIC-CXR dataset, surpassing the previous state-of-the-art unimodal (84.4%) and multimodal (86.0%) methods.
- The model shows strong robustness to typographical errors, with performance dropping by at most -1.7% micro AUROC under keyboard typos.
- When the indication field is missing or replaced with stop words, the model’s performance degrades to match the ResNet-50 image-only baseline, indicating reliance on textual input when available.
- Replacing the indication with a different patient’s text causes a significant performance drop of -9.8% on micro AUROC and -16.6% on macro AUROC, confirming the model uses both modalities for decision-making.
- The model maintains high performance across all 14 diseases, with the highest AUROC of 92.2% for 'Support Devices' and 88.6% for 'Pleural Effusion'.
- The method demonstrates that prior clinical knowledge from the indication field can be effectively leveraged by a fine-tuned BERT-based architecture to improve diagnostic accuracy in chest X-ray classification.