[Paper Review] Inference of visual field test performance from OCT volumes using deep learning
This study proposes a 3D convolutional neural network (CNN) to infer visual field test (VFT) metrics—Visual Field Index (VFI) and Mean Deviation (MD)—directly from raw optical coherence tomography (OCT) volumes of the optic nerve head (ONH) or macula, bypassing segmentation and registration. The CNN achieved a Pearson correlation of 0.88 ± 0.035 for VFI and 0.88 ± 0.023 for MD on ONH scans, significantly outperforming classical machine learning models like Random Forest (PC = 0.74 ± 0.090).
Visual field tests (VFT) are pivotal for glaucoma diagnosis and conducted regularly to monitor disease progression. Here we address the question to what degree aggregate VFT measurements such as Visual Field Index (VFI) and Mean Deviation (MD) can be inferred from Optical Coherence Tomography (OCT) scans of the Optic Nerve Head (ONH) or the macula. Accurate inference of VFT measurements from OCT could reduce examination time and cost. We propose a novel 3D Convolutional Neural Network (CNN) for this task and compare its accuracy with classical machine learning (ML) algorithms trained on common, segmentation-based OCT, features employed for glaucoma diagnostics. Peak accuracies were achieved on ONH scans when inferring VFI with a Pearson Correlation (PC) of 0.88$\\pm$0.035 for the CNN and a significantly lower (p $<$ 0.01) PC of 0.74$\\pm$0.090 for the best performing, classical ML algorithm - a Random Forest regressor. Estimation of MD was equally accurate with a PC of 0.88$\\pm$0.023 on ONH scans for the CNN.
Motivation & Objective
- To investigate whether aggregate visual field test (VFT) metrics like VFI and MD can be accurately inferred from raw OCT volumes without segmentation or registration.
- To compare the performance of a 3D CNN against classical machine learning models trained on standard segmentation-based OCT features.
- To evaluate the feasibility of replacing or reducing reliance on visual field testing in glaucoma diagnosis and progression monitoring.
- To assess the interpretability of the deep learning model using class activation maps (CAMs) to identify relevant retinal regions for prediction.
- To determine whether the model's performance is limited by inherent variability in VFT measurements or by structural limitations in OCT data.
Proposed method
- A 3D Convolutional Neural Network (CNN) is trained end-to-end on raw, downsampled OCT volumes (64×64×128) of the ONH or macula, with no prior segmentation.
- The network is trained to predict VFI and MD using mean squared error loss, with data split into 80% training, 10% validation, and 10% test sets, preserving patient-level data integrity.
- Performance is evaluated using Root Mean Square Error (RMSE) and Pearson Correlation (PC), with PC computed as the standard correlation coefficient between predicted and true values.
- Class Activation Maps (CAMs) are generated to visualize which regions of the OCT volume contribute most to the prediction, aiding interpretability.
- Data augmentation techniques including random occlusions, translations, small rotations (±10°), and mixup were explored but not used in final results due to no significant accuracy gain.
- The model does not use age or intraocular pressure (IOP) as input, relying solely on raw OCT intensity volumes for prediction.
Experimental results
Research questions
- RQ1Can aggregate VFT metrics such as VFI and MD be accurately inferred from raw OCT volumes without segmentation or registration?
- RQ2How does the performance of a 3D CNN compare to classical machine learning models (e.g., Random Forest, SVM) trained on standard segmentation-based OCT features?
- RQ3To what extent do class activation maps (CAMs) reveal biologically plausible regions of the OCT volume that correlate with visual field loss?
- RQ4Is the performance of the deep learning model limited by the inherent variability of visual field tests or by structural artifacts in OCT imaging?
- RQ5Does the absence of explicit segmentation and registration improve robustness in moderate to severe glaucoma cases compared to prior methods?
Key findings
- The 3D CNN achieved a Pearson correlation (PC) of 0.88 ± 0.035 for VFI and 0.88 ± 0.023 for MD when using ONH scans, significantly outperforming the best classical model (Random Forest) with a PC of 0.74 ± 0.090 (p < 0.01).
- The CNN's performance on the full dataset reached a PC of 0.93 for VFI, indicating strong generalization, though the test fold PC was 0.88, which remains high and robust.
- Class activation maps (CAMs) revealed that the network focuses on the GCIPL (ganglion cell and inner plexiform layer) in healthy eyes, and progressively highlights specific thinning regions in advanced glaucoma (VFI = 50, 30).
- The model's performance is close to the upper bound of VFT reliability, as retest variability in VFTs has been reported to correlate at r = 0.88, suggesting the CNN may be approaching the practical limit of inference accuracy.
- The use of raw OCT volumes without segmentation or registration avoids errors common in multi-field OCT registration and layer segmentation, particularly in advanced glaucoma.
- Despite exploring data augmentation (occlusions, rotations, mixup), no significant improvement in accuracy was observed, indicating the model may already be near optimal for the current data distribution.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.