[Paper Review] Influence of Heat Treatment on the Corrosion Behavior of Purified Magnesium and AZ31 Alloy

Sohrab Khalifeh, Thomas D. Burleigh|arXiv (Cornell University)|Jun 27, 2017
Magnesium Alloys: Properties and ApplicationsMaterials Science10 references4 citations
TL;DR

This study investigates how heat treatment enhances the corrosion resistance of high-purity magnesium (HP-Mg) and AZ31 alloy in simulated body fluid at 37°C. By optimizing temperature and duration, heat treatment increased corrosion resistance by 2× for HP-Mg and 10× for AZ31, as confirmed by hydrogen evolution, weight loss, potentiodynamic polarization (PDP), and electrochemical impedance spectroscopy (EIS) measurements.

ABSTRACT

Magnesium and its alloys are ideal for biodegradable implants due to their biocompatibility and their low-stress shielding. However, they can corrode too rapidly in the biological environment. The objective of this research was to develop heat treatments to slow the corrosion of high purified magnesium and AZ31 alloy in simulated body fluid at 37°C. Heat treatments were performed at different temperatures and times. Hydrogen evolution, weight loss, PDP, and EIS methods were used to measure the corrosion rates. Results show that heat treating can increase the corrosion resistance of HP-Mg by 2x and AZ31 by 10x.

Motivation & Objective

  • To address the rapid corrosion of magnesium and its alloys in physiological environments, which limits their use in biodegradable implants.
  • To investigate whether heat treatment can reduce the corrosion rate of high-purity magnesium (HP-Mg) and AZ31 alloy.
  • To identify optimal heat treatment parameters (temperature and time) that maximize corrosion resistance.
  • To evaluate the effectiveness of heat treatment using multiple electrochemical and gravimetric techniques in simulated body fluid at 37°C.

Proposed method

  • Heat treatments were applied to high-purity magnesium (HP-Mg) and AZ31 alloy at varying temperatures and durations.
  • Corrosion rates were quantified using hydrogen evolution measurements to assess hydrogen gas release during corrosion.
  • Weight loss measurements were conducted over time to determine mass loss due to corrosion.
  • Potentiodynamic polarization (PDP) was used to measure corrosion current density and electrochemical kinetics.
  • Electrochemical impedance spectroscopy (EIS) was employed to analyze charge transfer resistance and interfacial properties.
  • All tests were performed in simulated body fluid (SBF) at 37°C to mimic physiological conditions.

Experimental results

Research questions

  • RQ1How does heat treatment affect the corrosion rate of high-purity magnesium in simulated body fluid?
  • RQ2To what extent can heat treatment reduce the corrosion rate of AZ31 alloy in a physiological environment?
  • RQ3What are the optimal heat treatment parameters (temperature and time) that maximize corrosion resistance in HP-Mg and AZ31?
  • RQ4How do hydrogen evolution, weight loss, PDP, and EIS correlate in assessing the corrosion behavior of heat-treated Mg and AZ31?

Key findings

  • Heat treatment increased the corrosion resistance of high-purity magnesium (HP-Mg) by a factor of 2 compared to untreated samples.
  • For AZ31 alloy, heat treatment improved corrosion resistance by a factor of 10, significantly reducing the corrosion rate.
  • Hydrogen evolution measurements confirmed a substantial reduction in hydrogen gas production after heat treatment, indicating lower corrosion activity.
  • Weight loss data showed consistent and measurable reductions in mass loss for both HP-Mg and AZ31 after heat treatment.
  • PDP results revealed lower corrosion current densities for heat-treated samples, confirming reduced electrochemical corrosion rates.
  • EIS analysis demonstrated increased charge transfer resistance in heat-treated samples, indicating a more protective surface layer.