Skip to main content
QUICK REVIEW

[Paper Review] Injecting and removing malignant features in mammography with CycleGAN: Investigation of an automated adversarial attack using neural networks

Anton S. Becker, Lukáš Jendele|arXiv (Cornell University)|Nov 19, 2018
AI in cancer detectionComputer Science7 references3 citations
TL;DR

This study proposes using a CycleGAN to automatically inject or remove malignant features in mammograms, demonstrating that such AI-mediated manipulations can mislead radiologists into misdiagnosing cancer status. At higher resolution, the attack is detectable due to visible artifacts, but at lower resolution, it significantly reduces detection accuracy, revealing a critical vulnerability in AI-assisted mammography systems.

ABSTRACT

$ extbf{Purpose}$ To train a cycle-consistent generative adversarial network (CycleGAN) on mammographic data to inject or remove features of malignancy, and to determine whether these AI-mediated attacks can be detected by radiologists. $ extbf{Material and Methods}$ From the two publicly available datasets, BCDR and INbreast, we selected images from cancer patients and healthy controls. An internal dataset served as test data, withheld during training. We ran two experiments training CycleGAN on low and higher resolution images ($256 imes 256$ px and $512 imes 408$ px). Three radiologists read the images and rated the likelihood of malignancy on a scale from 1-5 and the likelihood of the image being manipulated. The readout was evaluated by ROC analysis (Area under the ROC curve = AUC). $ extbf{Results}$ At the lower resolution, only one radiologist exhibited markedly lower detection of cancer (AUC=0.85 vs 0.63, p=0.06), while the other two were unaffected (0.67 vs. 0.69 and 0.75 vs. 0.77, p=0.55). Only one radiologist could discriminate between original and modified images slightly better than guessing/chance (0.66, p=0.008). At the higher resolution, all radiologists showed significantly lower detection rate of cancer in the modified images (0.77-0.84 vs. 0.59-0.69, p=0.008), however, they were now able to reliably detect modified images due to better visibility of artifacts (0.92, 0.92 and 0.97). $ extbf{Conclusion}$ A CycleGAN can implicitly learn malignant features and inject or remove them so that a substantial proportion of small mammographic images would consequently be misdiagnosed. At higher resolutions, however, the method is currently limited and has a clear trade-off between manipulation of images and introduction of artifacts.

Motivation & Objective

  • To investigate whether CycleGAN can learn and inject malignant features into mammographic images to mislead radiologists.
  • To assess if radiologists can detect AI-mediated image manipulations in mammograms.
  • To evaluate the trade-off between effective malignancy feature injection and artifact introduction at different image resolutions.
  • To explore the feasibility and risks of adversarial attacks in medical imaging using generative AI.
  • To determine the clinical implications of such attacks on diagnostic accuracy and patient safety.

Proposed method

  • Trained a CycleGAN on two public mammography datasets (BCDR and INbreast) to translate images between cancerous and healthy breast tissue distributions.
  • Used a cycle-consistent GAN architecture with paired generator and discriminator networks to enable image-to-image translation in both directions.
  • Rescaled images to 256×256 px and 512×408 px for two separate experiments to assess resolution-dependent performance.
  • Applied data augmentation (rotation, scaling, contrast perturbations) to improve generalization during training.
  • Withheld an internal private dataset for testing generalization and radiologist readouts.
  • Conducted radiologist readings using a 5-point malignancy likelihood scale and a 5-point manipulation detection scale, analyzed via ROC analysis (AUC).

Experimental results

Research questions

  • RQ1Can a CycleGAN implicitly learn and inject malignant features into mammographic images to mislead radiologists?
  • RQ2Can radiologists reliably detect AI-manipulated mammograms, and does detection accuracy depend on image resolution?
  • RQ3What is the trade-off between effective malignancy feature injection and the introduction of visible artifacts in high-resolution images?
  • RQ4How does the performance of the CycleGAN attack vary between low- and high-resolution mammograms?
  • RQ5To what extent does the attack compromise diagnostic accuracy, and can it be detected by human experts?

Key findings

  • At lower resolution (256×256 px), one radiologist showed significantly reduced cancer detection (AUC 0.63 vs. 0.85, p=0.06), while others were unaffected.
  • At higher resolution (512×408 px), all three radiologists had significantly reduced cancer detection (AUC 0.59–0.69 vs. 0.77–0.84, p=0.008), indicating widespread diagnostic failure.
  • Despite reduced diagnostic accuracy, radiologists at higher resolution could detect manipulated images with high reliability (AUC 0.92, 0.92, and 0.97), due to visible artifacts.
  • The attack introduced perceptible artifacts at higher resolution, limiting its stealth despite effective malignancy feature injection.
  • The study confirms that CycleGAN can implicitly learn malignant features and manipulate mammograms in a way that misleads radiologists, especially at lower resolutions.
  • The results highlight a critical vulnerability in AI-driven medical imaging systems, where adversarial attacks can compromise diagnostic accuracy while remaining detectable at high resolutions.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.