[Paper Review] INTEGRAL Cross-calibration Status

P. Lubiński, P. Dubath|arXiv (Cornell University)|May 24, 2004
Astrophysical Phenomena and ObservationsPhysics and Astronomy5 citations
TL;DR

This paper evaluates the cross-calibration status of INTEGRAL's instruments using the Crab Nebula and weaker sources like Cyg X-1, 3C 273, and NGC 4151. It finds significant flux normalization and spectral shape issues in JEM-X 2 and ISGRI, especially below 7 keV and below 100 keV, respectively, while SPI shows good agreement with models. The key contribution is identifying calibration limitations and guiding improvements ahead of OSA 4.0 release.

ABSTRACT

The status of the INTEGRAL cross-calibration is presented for a standard X-ray astronomy source, the Crab Nebula, as well as for some weaker sources. The relative flux normalization for the different INTEGRAL instruments is discussed together with spectral shape features.

Motivation & Objective

  • Assess the cross-calibration accuracy of INTEGRAL's instruments using the Crab Nebula as a standard source.
  • Identify spectral shape and flux normalization discrepancies across INTEGRAL's instruments (JEM-X, ISGRI, SPI).
  • Examine the impact of background modeling on weak source spectral extraction.
  • Compare spectral results from OSA 2.0 and OSA 3.0 software releases to evaluate calibration improvements.
  • Provide relative normalization factors for INTEGRAL instruments using RXTE data as a reference for weaker sources.

Proposed method

  • Extracted INTEGRAL spectra from revolution 102 (Crab) and other revolutions for Cyg X-1, 3C 273, and NGC 4151 using OSA 3.0 software.
  • Performed spectral fitting using XSPEC 11.3 with a canonical power-law model (Γ = 2.1, A = 9.7 photons cm⁻² s⁻¹ keV⁻¹) and NH = 3.45 × 10²¹ cm⁻² for the Crab.
  • Fixed model parameters and fitted relative normalization factors for JEM-X 2, ISGRI, and SPI to assess instrument consistency.
  • Applied statistical errors and tested systematic errors (10%) for ISGRI to improve χ² and model fit quality.
  • Compared spectral ratios between INTEGRAL data and RXTE best-fit models for weaker sources, using reference models from RXTE data.
  • Evaluated alternative spectral extraction methods for ISGRI, including standard (S) and mosaic-image-based (O) approaches to reduce spectral distortions.

Experimental results

Research questions

  • RQ1How accurate is the relative flux normalization across INTEGRAL's JEM-X 2, ISGRI, and SPI instruments when observing the Crab Nebula?
  • RQ2What spectral shape distortions are present in INTEGRAL data, particularly in JEM-X 2 below 7 keV and ISGRI below 100 keV?
  • RQ3How do the OSA 3.0 and OSA 2.0 software releases affect spectral calibration and normalization for INTEGRAL instruments?
  • RQ4To what extent do background modeling uncertainties impact flux measurements for weak sources like 3C 273 and NGC 4151?
  • RQ5What is the relative normalization of INTEGRAL instruments compared to RXTE data for Cyg X-1, NGC 4151, and 3C 273?

Key findings

  • The JEM-X 2 spectrum exhibits an artificial absorption excess below 7 keV due to incorrect flux reconstruction, making it appear more absorbed than it is.
  • ISGRI spectra show 'snake-like' distortions below 100 keV and a declining flux above 200 keV, indicating calibration issues with response matrices.
  • SPI spectra show good agreement with the canonical Crab model, being smooth and well-normalized in the 30–200 keV range.
  • Relative normalization for JEM-X 2 is 0.82, ISGRI is 0.75, and SPI is 1.21 (with respect to the canonical model) for the Crab Nebula in revolution 102.
  • Alternative ISGRI spectral extraction from mosaic images (O) reduces spectral distortions and improves shape, though with slightly worse absolute normalization than standard (S) extraction.
  • Relative normalization factors for weaker sources (Cyg X-1, 3C 273, NGC 4151) are inconsistent with stronger sources, indicating background modeling and calibration uncertainties at low flux levels.

Read this paper