[Paper Review] Interference Mitigation Using Uplink Power Control for Two-Tier Femtocell Networks
This paper proposes open-loop and closed-loop uplink power control schemes for femtocell users in two-tier CDMA networks to mitigate cross-tier interference at macrocell base stations (BS). The open-loop scheme uses a fixed interference threshold, while the closed-loop scheme adapts the maximum transmit power based on real-time noise and interference (NI) levels at the macrocell BS, achieving superior femtocell throughput with minimal macrocell throughput cost.
This paper proposes two interference mitigation strategies that adjust the maximum transmit power of femtocell users to suppress the cross-tier interference at a macrocell base station (BS). The open-loop and the closed-loop control suppress the cross-tier interference less than a fixed threshold and an adaptive threshold based on the noise and interference (NI) level at the macrocell BS, respectively. Simulation results show that both schemes effectively compensate the uplink throughput degradation of the macrocell BS due to the cross-tier interference and that the closed-loop control provides better femtocell throughput than the open-loop control at a minimal cost of macrocell throughput.
Motivation & Objective
- Address the challenge of uplink cross-tier interference from femtocell users degrading macrocell base station (BS) performance in two-tier CDMA networks.
- Develop self-configuring, automatic interference mitigation techniques suitable for consumer-deployed femtocells without centralized control.
- Minimize macrocell throughput degradation while enhancing femtocell throughput through adaptive power control.
- Evaluate the performance of interference mitigation strategies under varying femtocell density and propagation conditions.
Proposed method
- Propose an open-loop power control scheme that sets a fixed maximum transmit power for femtocell users to limit cross-tier interference below a predefined threshold.
- Design a closed-loop power control scheme that dynamically adjusts the femtocell user's maximum transmit power based on the real-time noise and interference (NI) level measured at the macrocell BS.
- Utilize path loss models based on ITU and COST231 standards, including wall penetration loss (Le and Li), frequency dependence, and shadowing effects.
- Apply uplink open-loop power control principles using downlink received signal strength and broadcast EIRP information to estimate required uplink transmit power.
- Integrate shadowing and log-normal fading effects (standard deviation 8 dB for outdoor, 10 dB for indoor) and model wall losses as random variables.
- Implement a threshold-based interference suppression mechanism where the maximum transmit power is constrained to maintain cross-tier interference below a target level.
Experimental results
Research questions
- RQ1How does open-loop uplink power control based on a fixed interference threshold affect macrocell and femtocell throughput in two-tier femtocell networks?
- RQ2To what extent does closed-loop power control, which adapts to real-time NI levels at the macrocell BS, improve femtocell performance compared to open-loop control?
- RQ3What is the trade-off between macrocell throughput degradation and femtocell throughput gain when using closed-loop versus open-loop power control?
- RQ4How does the performance of both schemes vary with increasing femtocell density (M) and varying wall penetration loss (Le and Li) conditions?
- RQ5In what propagation scenarios (e.g., low distance D, low Le) does the closed-loop scheme provide the greatest performance gain for edge femtocell users?
Key findings
- The closed-loop power control scheme achieves up to 120% higher 5% user throughput in femtocells compared to open-loop control, particularly benefiting users with low path loss and high interference exposure.
- The closed-loop scheme improves femtocell average throughput by up to 8% over open-loop control, with minimal macrocell throughput degradation.
- At high femtocell density (M), the closed-loop control maintains cross-tier interference below the threshold, while the fixed-power scheme causes significant macrocell throughput degradation.
- The 5% user throughput of macrocells follows a similar trend to average throughput, indicating consistent interference impact across all macrocell users.
- The performance gain of closed-loop over open-loop control increases as the distance D and external wall loss Le decrease, where cross-tier interference dominates the NI level.
- The closed-loop control provides the most significant gains in scenarios with low D and low Le, where femtocell users are close to the macrocell BS and face high interference from neighboring femtocells.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.