TL;DR

This paper proposes a K-margin-based Residual-Convolution-Recurrent Neural Network (RCR-net) for robust atrial fibrillation (AF) detection in noisy ECGs. By combining skewness-driven dynamic data augmentation, multi-scale feature extraction via residual-convolutional-recurrent architecture, and a K-margin-based voting mechanism that focuses on top-K uncertain segments, the method achieves an F₁NAOP score of 0.8125, outperforming all prior deep learning methods by 6.8% on the PhysioNet 2017 dataset.

ABSTRACT

Atrial Fibrillation (AF) is an abnormal heart rhythm which can trigger cardiac arrest and sudden death. Nevertheless, its interpretation is mostly done by medical experts due to high error rates of computerized interpretation. One study found that only about 66% of AF were correctly recognized from noisy ECGs. This is in part due to insufficient training data, class skewness, as well as semantical ambiguities caused by noisy segments in an ECG record. In this paper, we propose a K-margin-based Residual-Convolution-Recurrent neural network (K-margin-based RCR-net) for AF detection from noisy ECGs. In detail, a skewness-driven dynamic augmentation method is employed to handle the problems of data inadequacy and class imbalance. A novel RCR-net is proposed to automatically extract both long-term rhythm-level and local heartbeat-level characters. Finally, we present a K-margin-based diagnosis model to automatically focus on the most important parts of an ECG record and handle noise by naturally exploiting expected consistency among the segments associated for each record. The experimental results demonstrate that the proposed method with 0.8125 F1NAOP score outperforms all state-of-the-art deep learning methods for AF detection task by 6.8%.

Motivation & Objective

  • To address the challenge of low accuracy in AF detection from noisy ECGs due to data scarcity, class imbalance, and semantical ambiguities from noise.
  • To develop an end-to-end deep learning model that automatically learns both local heartbeat-level and long-term rhythm-level features without manual feature engineering.
  • To improve robustness to noise and label ambiguity by focusing on the most informative segments through a K-margin-based diagnosis mechanism.
  • To outperform existing deep learning models on the PhysioNet 2017 AF detection benchmark, particularly in handling noisy and ambiguous ECG records.

Proposed method

  • A skewness-driven dynamic data augmentation strategy is used to address data scarcity and class imbalance by generating synthetic samples based on the skewness of the original ECG distribution.
  • A novel Residual-Convolution-Recurrent Neural Network (RCR-net) is designed to extract hierarchical features: convolutional layers capture local heartbeat patterns, while recurrent layers model long-term rhythm dynamics.
  • The K-margin-based diagnosis model selects the top-K most uncertain segments from each ECG record and uses their confidence margins to vote for the final label, enhancing robustness to noise and ambiguity.
  • The model leverages expected consistency among segments of the same ECG record, prioritizing segments with minimal prediction margin to improve generalization.
  • The framework integrates data augmentation, feature learning, and uncertainty-aware classification into a unified pipeline for end-to-end training and inference.
  • Hyperparameter tuning is performed on window size, maximum stride, and number of splits to balance local feature retention and global rhythm modeling.

Experimental results

Research questions

  • RQ1Can a deep learning model effectively detect AF in noisy ECGs when training data is limited and class-imbalanced?
  • RQ2How can a model automatically focus on the most diagnostically relevant segments of an ECG while suppressing noise-induced ambiguities?
  • RQ3To what extent can a K-margin-based voting mechanism improve classification performance by leveraging uncertainty and consistency across ECG segments?
  • RQ4Can a residual-convolutional-recurrent architecture effectively capture both local beat-level and long-term rhythm-level features in ECG signals?
  • RQ5Does dynamic data augmentation based on data skewness lead to better generalization than standard augmentation in AF detection?

Key findings

  • The proposed K-margin-based RCR-net achieves an F₁NAOP score of 0.8125 on the PhysioNet 2017 dataset, representing a 6.8% improvement over all state-of-the-art deep learning methods.
  • The model demonstrates superior robustness to noise, particularly in identifying 'Too Noisy To Classify' records, due to its uncertainty-aware segment selection mechanism.
  • The confusion matrix analysis shows that misclassifications are largely interpretable, such as between Normal Sinus Rhythm and Other Rhythm, which are clinically challenging to distinguish.
  • The K-margin-based voting mechanism improves performance by focusing on the most uncertain yet informative segments, with optimal performance at K=3, beyond which performance degrades due to reduced label confidence.
  • Hyperparameter analysis confirms that smaller ECG segment windows (e.g., 50–1000 ms) improve performance by enabling better capture of rhythm trends, while excessively small windows lose critical local beat features.
  • The model’s learned deep features are highly distinguishable across the four classes (Normal, AF, Other Rhythm, Too Noisy), as shown by feature visualization, indicating effective representation learning.

Read this paper