Skip to main content
QUICK REVIEW

[Paper Review] Keep Me Around: Intron Retention Detection and Analysis

Harold Pimentel, John G. Conboy|arXiv (Cornell University)|Oct 2, 2015
Model Reduction and Neural NetworksPhysics and Astronomy8 references16 citations
TL;DR

This paper introduces kma, a computational tool that detects intron retention (IR) in RNA-Seq data by integrating biological replicates to reduce false positives. It extends existing quantification pipelines using an augmented transcriptome and applies a resampling-based hypothesis test to identify statistically significant IR events with improved accuracy over existing tools.

ABSTRACT

We present a tool, keep me around (kma), a suite of python scripts and an R package that finds retained introns in RNA-Seq experiments and incorporates biological replicates to reduce the number of false positives when detecting retention events. kma uses the results of existing quantification tools that probabilistically assign multi-mapping reads, thus interfacing easily with transcript quantification pipelines. The data is represented in a convenient, database style format that allows for easy aggregation across introns, genes, samples, and conditions to allow for further exploratory analysis.

Motivation & Objective

  • To address the lack of tools that use biological replicates to reduce false-positive intron retention (IR) detection in RNA-Seq experiments.
  • To develop a method that integrates with existing transcript quantification pipelines without requiring major reimplementation.
  • To provide a statistically rigorous approach for identifying significant IR events using resampling-based hypothesis testing.
  • To enable flexible, database-style data representation for efficient aggregation and exploratory analysis across genes, samples, and conditions.
  • To offer a user-friendly, open-source solution with support for multiple quantification tools and extensible data formats.

Proposed method

  • kma performs a pre-processing step to identify 'inclusion regions'—intronic regions flanked by exons—where reads spanning junctions can be captured.
  • It generates a custom transcriptome by adding intronic sequences to the reference, enabling quantification of intron expression using any additive unit (e.g., TPM).
  • The tool uses existing quantification tools like eXpress to estimate expression levels, including multi-mapping reads via probabilistic models.
  • Retention is calculated as the ratio of intron expression to total expression (intron + overlapping transcripts), known as the proportion spliced in (PSI).
  • A zero-coverage filter computes the probability of observing a read-free region in an intron, removing low-confidence events if the probability is too low.
  • A resampling-based hypothesis test generates a null distribution by randomly sampling retention values across replicates per condition, computing p-values to assess significance.

Experimental results

Research questions

  • RQ1Can intron retention events be detected with reduced false positives by incorporating biological replicates into the analysis?
  • RQ2How can existing RNA-Seq quantification pipelines be extended to include intron expression estimation without major re-implementation?
  • RQ3What statistical framework best identifies significant intron retention events while accounting for technical and biological variability?
  • RQ4To what extent can database-style data structures improve the scalability and flexibility of IR analysis across multiple samples and conditions?
  • RQ5How effective is a zero-coverage filter in removing unreliable retention estimates due to low or absent read coverage?

Key findings

  • kma reduces false-positive intron retention detection by using a resampling-based hypothesis test that compares observed mean retention to a null distribution generated from biological replicates.
  • The tool successfully integrates with existing quantification pipelines such as eXpress, enabling the use of probabilistic multi-mapping read assignment without requiring changes to the core pipeline.
  • The database-like data format in R allows for fast aggregation and analysis using standard data manipulation packages like dplyr and visualization tools like ggplot2.
  • The zero-coverage filter effectively removes introns with low or no read support, reducing noise from regions with insufficient evidence of expression.
  • The method achieves robust detection of biologically relevant IR events, such as the retained intron 4 in the SF3B1 gene, which showed consistent retention across all replicates in a published dataset.
  • The tool is extensible, with support for multiple quantification formats and the ability to add new data readers with minimal code, enhancing its adoption in diverse pipelines.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.