Skip to main content
QUICK REVIEW

[Paper Review] Learning-Assisted Competitive Algorithms for Peak-Aware Energy Scheduling

Russell Lee, Mohammad Hajiesmaili|arXiv (Cornell University)|Nov 18, 2019
Optimization and Search ProblemsComputer Science23 references8 citations
TL;DR

This paper proposes learning-assisted competitive algorithms for peak-aware energy scheduling in data centers, integrating machine learning predictions to improve performance while maintaining worst-case robustness. The proposed ${\lambda}\texttt{BED}$ algorithm achieves 15.13% better performance than pure online algorithms on real data, with provably optimal behavior as prediction error approaches zero.

ABSTRACT

In this paper, we study the peak-aware energy scheduling problem using the competitive framework with machine learning prediction. With the uncertainty of energy demand as the fundamental challenge, the goal is to schedule the energy output of local generation units such that the electricity bill is minimized. While this problem has been tackled using classic competitive design with worst-case guarantee, the goal of this paper is to develop learning-assisted competitive algorithms to improve the performance in a provable manner. We develop two deterministic and randomized algorithms that are provably robust against the poor performance of learning prediction, however, achieve the optimal performance as the error of prediction goes to zero. Extensive experiments using real data traces verify our theoretical observations and show 15.13% improved performance against pure online algorithms.

Motivation & Objective

  • Address the challenge of peak-aware energy scheduling in data centers with uncertain, volatile energy demand.
  • Improve upon traditional online algorithms that are overly conservative due to worst-case performance guarantees.
  • Integrate machine learning predictions into competitive algorithms to achieve better performance when predictions are accurate, while preserving robustness against poor predictions.
  • Maintain theoretical performance guarantees (competitive ratio) even when predictions are inaccurate, ensuring reliability in real-world deployment.

Proposed method

  • Design a learning-augmented variant of the BED (Best-Effort Dispatch) algorithm, named ${\lambda}\texttt{BED}$, which blends online decisions with ML predictions.
  • Use a parameter $\lambda$ to balance between the ML prediction and the conservative online strategy, ensuring robustness when predictions are inaccurate.
  • Formulate the energy scheduling problem as a hybrid cost function combining volume pricing and peak pricing, with peak demand multiplied by a high peak price $p_m$.
  • Apply a projection-based method to enforce ramp constraints on generator output, ensuring physical feasibility of the schedule.
  • Introduce a consistency-robustness framework to theoretically analyze performance: consistency measures improvement with accurate predictions, robustness ensures worst-case performance bounds.
  • Use real-world data traces from data centers to empirically validate theoretical claims and compare performance against pure online algorithms.

Experimental results

Research questions

  • RQ1Can machine learning predictions be integrated into competitive online algorithms for energy scheduling without sacrificing worst-case performance guarantees?
  • RQ2How does the performance of learning-augmented algorithms scale with prediction accuracy, and what is the theoretical trade-off between consistency and robustness?
  • RQ3To what extent can learning-assisted algorithms reduce electricity costs in real-world data center energy scheduling compared to pure online methods?
  • RQ4How do system constraints such as ramp limits and generator capacity affect the performance of learning-augmented algorithms?
  • RQ5Does the proposed algorithm outperform existing online algorithms, especially in regimes where pure online algorithms degrade (e.g., high generator capacity)?

Key findings

  • The ${\lambda}\texttt{BED}$ algorithm achieves 15.13% lower electricity costs than pure online algorithms on real data traces, demonstrating significant practical improvement.
  • As prediction error approaches zero, ${\lambda}\texttt{BED}$ achieves optimal performance, matching the theoretical lower bound of the offline optimal solution.
  • The algorithm maintains provably robust performance even when predictions are poor, ensuring worst-case guarantees are preserved.
  • Performance degradation of pure online algorithms like BED is observed when generator capacity exceeds 60% of peak demand; ${\lambda}\texttt{BED}$ avoids this by leveraging predictions.
  • Competitive ratios of ${\lambda}\texttt{BED}$ are consistently better than BED across all peak price levels, with the largest gains in intermediate peak price regimes.
  • Relaxing ramp constraints increases competitive ratios for both algorithms, but ${\lambda}\texttt{BED}$ maintains superior performance due to better utilization of prediction and flexibility.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.