This paper proposes a deep reinforcement learning (DRL) framework to learn personalized CT scanning strategies that optimize measurement angle selection and dose allocation per patient. By formulating CT scanning as a Markov Decision Process (MDP) and training with Proximal Policy Optimization (PPO), the method achieves superior image reconstruction quality—measured by PSNR and SSIM—compared to random or uniform sampling, and generalizes across multiple reconstruction algorithms including TV, wavelet frames, and deep learning models like PD-net.
Computed Tomography (CT) takes X-ray measurements on the subjects to reconstruct tomographic images. As X-ray is radioactive, it is desirable to control the total amount of dose of X-ray for safety concerns. Therefore, we can only select a limited number of measurement angles and assign each of them limited amount of dose. Traditional methods such as compressed sensing usually randomly select the angles and equally distribute the allowed dose on them. In most CT reconstruction models, the emphasize is on designing effective image representations, while much less emphasize is on improving the scanning strategy. The simple scanning strategy of random angle selection and equal dose distribution performs well in general, but they may not be ideal for each individual subject. It is more desirable to design a personalized scanning strategy for each subject to obtain better reconstruction result. In this paper, we propose to use Reinforcement Learning (RL) to learn a personalized scanning policy to select the angles and the dose at each chosen angle for each individual subject. We first formulate the CT scanning process as an MDP, and then use modern deep RL methods to solve it. The learned personalized scanning strategy not only leads to better reconstruction results, but also shows strong generalization to be combined with different reconstruction algorithms.
Motivation & Objective
- To address the limitation of fixed, non-personalized scanning strategies in CT imaging that do not adapt to individual patient anatomy.
- To reduce radiation dose while maintaining or improving image reconstruction quality by learning optimal scanning policies.
- To develop a personalized scanning strategy that dynamically selects angles and allocates dose based on real-time measurement feedback during scanning.
- To demonstrate generalization of the learned policy across diverse reconstruction algorithms, including traditional regularization and deep learning models.
Proposed method
- The CT scanning process is modeled as a Markov Decision Process (MDP), where the state includes collected measurements, actions select the next angle and dose level, and rewards are based on reconstruction quality.
- A deep Q-network with a ResNet-based encoder processes the state representation to estimate action values in the DRL framework.
- The Proximal Policy Optimization (PPO) algorithm is used to train the policy network, enabling stable and efficient learning of the personalized scanning strategy.
- The reward function is computed using a reconstruction algorithm (e.g., SART) at each time step, providing dense feedback for policy optimization.
- The method supports irregular, non-uniform scanning patterns by learning to select angles and doses adaptively based on image complexity.
- The policy is trained end-to-end on 250 real 2D CT images and evaluated on 350 unseen test images to assess generalization and performance.
Experimental results
Research questions
- RQ1Can reinforcement learning learn a personalized scanning policy that outperforms random or uniform sampling in CT image reconstruction?
- RQ2How well does a single trained RL policy generalize across different reconstruction algorithms such as TV, wavelet frames, and deep learning models?
- RQ3Does the learned policy adapt its angle selection and dose allocation based on the anatomical complexity of individual patients?
- RQ4Can the RL policy maintain high reconstruction quality under varying noise levels and without explicit noise modeling during training?
- RQ5How does the distribution of selected angles and dose allocations vary across different patient scans?
Key findings
- The RL-AD policy achieved significantly higher PSNR and SSIM values than both dynamic sampling (DS-ED) and uniform sampling (UF-AEC) across all tested reconstruction algorithms.
- The RL policy improved reconstruction quality even when trained only with SART, demonstrating strong generalization to other algorithms including TV, wavelet frame, and PD-net.
- The policy adapted to patient-specific anatomy: images with more structural complexity received more measurement angles and lower per-angle dose.
- The distribution of selected angles and dose allocations varied significantly across subjects, confirming personalized adaptation rather than a fixed strategy.
- The policy generalized to different noise levels despite being trained only with Gaussian noise, indicating robustness to measurement variability.
- The learned policy selected 54–65 angles on complex images, with dose per angle decreasing as the number of angles increased, reflecting efficient dose allocation.