Skip to main content
QUICK REVIEW

[Paper Review] LEGEND: The Large Enriched Germanium Experiment for Neutrinoless Double-Beta Decay

Jordan Myslik|arXiv (Cornell University)|Oct 1, 2018
Neutrino Physics ResearchPhysics and Astronomy3 references7 citations
TL;DR

LEGEND proposes a phased, tonne-scale 76Ge experiment to search for neutrinoless double-beta decay, leveraging the ultra-low backgrounds and high energy resolution of GERDA and Majorana Demonstrator technologies. The collaboration aims for a discovery potential beyond 10^28 years by deploying 200 kg in the existing GERDA cryostat (LEGEND-200) and scaling to 1000 kg (LEGEND-1000), with background goals of <0.6 and <0.1 counts/(FWHM·t·y), respectively.

ABSTRACT

The lepton number violating process of neutrinoless double-beta decay could result from the physics beyond the Standard Model needed to generate the neutrino masses. Taking different approaches, the current generation of $^{76}$Ge experiments, the MAJORANA DEMONSTRATOR and GERDA, lead the field in both the ultra-low background and energy resolution achieved. The next generation of neutrinoless double-beta decay experiments requires increased mass and further reduction of backgrounds to maximize discovery potential. Building on the successes of the MAJORANA DEMONSTRATOR and GERDA, the LEGEND collaboration has been formed to pursue a tonne-scale $^{76}$Ge experiment, with discovery potential at a half-life beyond $10^{28}$ years. The collaboration aims to develop a phased neutrinoless double-beta decay experimental program, starting with a 200 kg measurement using the existing GERDA cryostat at LNGS. These proceedings discuss the plans and physics reach of LEGEND, and the combination of R&amp;D efforts and existing resources being employed to expedite physics results.

Motivation & Objective

  • Address the need for a next-generation 0νββ decay experiment with enhanced mass and reduced backgrounds to probe the inverted neutrino mass ordering.
  • Leverage proven technologies from GERDA and the Majorana Demonstrator to minimize development time and maximize background suppression.
  • Achieve a 3σ discovery potential for 0νββ decay half-life beyond 10^28 years through phased deployment of enriched germanium detectors.
  • Optimize detector design, front-end electronics, and shielding to reduce backgrounds from cosmogenic and intrinsic radioactivity.
  • Utilize existing infrastructure at LNGS for LEGEND-200 to accelerate physics results and maintain technical momentum toward LEGEND-1000.

Proposed method

  • Deploy up to 200 kg of enriched 76Ge detectors in the existing GERDA cryostat at LNGS, using liquid argon as an active veto and shielding.
  • Implement Low-Mass Front-End (LMFE) electronics with radiopure materials and minimal mass to reduce electronic backgrounds and preserve energy resolution.
  • Adopt Inverted-Coaxial Point Contact (ICPC) germanium detectors (1.5–2.0 kg each) to reduce cable and preamplifier count per kg, lowering background contributions.
  • Use underground argon with 42Ar removed in LEGEND-1000 to eliminate 42K ion background from natural argon, improving background suppression.
  • Apply pulse shape analysis and coincident γ-tagging to reject surface and multi-site events, enhancing signal purity.
  • Conduct R&D on ASIC preamplifiers for future LEGEND-1000, and optimize light collection in liquid argon with improved scintillation fibers and purity.

Experimental results

Research questions

  • RQ1Can a phased 76Ge experiment achieve a 3σ discovery potential for 0νββ decay half-life beyond 10^28 years with realistic background levels?
  • RQ2Can the existing GERDA cryostat at LNGS support a 200 kg enriched germanium detector array with backgrounds below 0.6 counts/(FWHM·t·y)?
  • RQ3What are the optimal detector geometries and shielding strategies to minimize backgrounds while scaling to 1000 kg of enriched 76Ge?
  • RQ4How can 42K ion backgrounds from natural argon be eliminated in future large-scale experiments?
  • RQ5Can radiopure, low-mass front-end electronics like the LMFE maintain excellent energy resolution and low noise in liquid argon environments?

Key findings

  • LEGEND-200 aims to achieve a background level of <0.6 counts/(FWHM·t·y), enabling a sensitivity greater than 10^27 years after 1 ton·y exposure.
  • The LEGEND-200 experiment is expected to begin physics data collection in 2021, using the existing GERDA cryostat and infrastructure.
  • The 1000 kg LEGEND-1000 phase targets a background goal of <0.1 counts/(FWHM·t·y), required for discovery potential beyond 10^28 years.
  • The Inverted-Coaxial Point Contact (ICPC) detector design enables larger detectors (1.5–2.0 kg) with performance comparable to BEGe and PPC types, reducing component count and background.
  • The use of underground argon with 42Ar removed in LEGEND-1000 can eliminate 42K ion background, a major source in natural argon.
  • R&D on ASIC preamplifiers and improved scintillation light collection in liquid argon is ongoing to support future scalability and performance.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.