Skip to main content
QUICK REVIEW

[Paper Review] LiDAR and Camera Calibration using Motion Estimated by Sensor Fusion Odometry

Ryoichi Ishikawa, Takeshi Oishi|arXiv (Cornell University)|Apr 14, 2018
Advanced Vision and ImagingComputer Science23 references12 citations
TL;DR

This paper proposes a targetless, automatic 2D-3D calibration method for camera-LiDAR systems using sensor fusion odometry to estimate scale-aware camera motion. By iteratively refining extrinsic parameters through motion estimation from fused LiDAR and RGB data, the method achieves higher accuracy than state-of-the-art approaches, especially in translation, without requiring initial parameters or reflectance data.

ABSTRACT

In this paper, we propose a method of targetless and automatic Camera-LiDAR calibration. Our approach is an extension of hand-eye calibration framework to 2D-3D calibration. By using the sensor fusion odometry method, the scaled camera motions are calculated with high accuracy. In addition to this, we clarify the suitable motion for this calibration method. The proposed method only requires the three-dimensional point cloud and the camera image and does not need other information such as reflectance of LiDAR and to give initial extrinsic parameter. In the experiments, we demonstrate our method using several sensor configurations in indoor and outdoor scenes to verify the effectiveness. The accuracy of our method achieves more than other comparable state-of-the-art methods.

Motivation & Objective

  • To develop a fully automatic, targetless calibration method for camera-LiDAR systems that avoids manual correspondence or special calibration targets.
  • To improve calibration accuracy by leveraging sensor fusion odometry to estimate camera motion with scale, overcoming the scale ambiguity inherent in monocular motion estimation.
  • To eliminate the need for initial extrinsic parameter estimates or reflectance data from LiDAR, enabling practical on-site calibration.
  • To validate the method across diverse indoor and outdoor scenes with varying sensor configurations and motion types.

Proposed method

  • Estimate LiDAR motion using iterative closest point (ICP) alignment of consecutive 3D point clouds.
  • Estimate initial camera motion using 2D feature point matching between consecutive RGB images, resulting in scale-ambiguous motion.
  • Use sensor fusion odometry to refine the camera motion with scale by fusing LiDAR point clouds and camera images using the initial extrinsic estimate.
  • Perform iterative hand-eye calibration using the refined, scale-aware camera motions and the LiDAR motions to update the extrinsic parameters.
  • Repeat the motion estimation and parameter refinement process until convergence of the extrinsic parameters.
  • Use only raw RGB images and 3D point clouds as input, without requiring reflectance data, initial parameter guesses, or manual correspondences.

Experimental results

Research questions

  • RQ1Can sensor fusion odometry be effectively used to estimate scale-aware camera motion for 2D-3D calibration without external targets?
  • RQ2What types of sensor motion are most effective for achieving high-accuracy calibration in a targetless, automatic setup?
  • RQ3How does the proposed method compare in accuracy to state-of-the-art methods when using minimal motion data?
  • RQ4Can the method achieve robust calibration using only standard RGB and 3D point cloud data, without requiring reflectance or initial parameter estimates?

Key findings

  • The proposed method achieves sub-degree rotational accuracy and significantly improved translation accuracy compared to scale-ambiguous motion-based methods.
  • In experiments with HDL-64E and Ladybug 3, the proposed method achieved less than 1° error in rotation and highly accurate translation, outperforming both scaleless motion and mutual information-based methods.
  • Manual calibration failed due to sparse point clouds and narrow scan angles, while the proposed method succeeded even with limited data and challenging sensor configurations.
  • The method is robust to vertical motion (e.g., platform elevation) and enables practical on-site calibration using only standard mobile platform operations.
  • The iterative refinement process converges reliably, demonstrating the effectiveness of combining sensor fusion odometry with hand-eye calibration.
  • The method does not require reflectance data or initial extrinsic parameter estimates, making it suitable for dynamic, real-world deployment.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.