Skip to main content
QUICK REVIEW

[Paper Review] Lighthouse Positioning System: Dataset, Accuracy, and Precision for UAV Research

Arnaud Taffanel, Barbara Rousselot|arXiv (Cornell University)|Apr 23, 2021
Robotics and Sensor-Based LocalizationEngineering14 references15 citations
TL;DR

This paper presents an open-source dataset and comprehensive analysis of the Lighthouse positioning system for UAV research, evaluating its accuracy and precision using onboard real-time tracking on Crazyflie 2.1 drones. It demonstrates that Lighthouse 2 (LH2) achieves sub-centimeter accuracy (mean error ~1–4 cm) and low jitter (0.3–0.7 mm), outperforming Lighthouse 1 (LH1), with both versions enabling viable alternatives to motion capture for distributed UAV swarms.

ABSTRACT

The Lighthouse system was originally developed as tracking system for virtual reality applications. Due to its affordable price, it has also found attractive use-cases in robotics in the past. However, existing works frequently rely on the centralized official tracking software, which make the solution less attractive for UAV swarms. In this work, we consider an open-source tracking software that can run onboard small Unmanned Aerial Vehicles (UAVs) in real-time and enable distributed swarming algorithms. We provide a dataset specifically for the use cases i) flight; and ii) as ground truth for other commonly-used distributed swarming localization systems such as ultra-wideband. We then use this dataset to analyze both accuracy and precision of the Lighthouse system in different use-cases. To our knowledge, we are the first to compare two different Lighthouse hardware versions with a motion capture system and the first to analyze the accuracy using tracking software that runs onboard a microcontroller.

Motivation & Objective

  • To provide a publicly available dataset for UAV research using the Lighthouse positioning system in flight, stationary, and manually moved scenarios.
  • To evaluate the accuracy and precision of the Lighthouse system when using open-source, real-time tracking software running onboard microcontrollers (e.g., Crazyflie 2.1).
  • To compare the performance of two Lighthouse hardware versions (LH1 and LH2) against a motion capture system as ground truth.
  • To enable the use of Lighthouse as a low-cost, distributed alternative to centralized motion capture systems in swarm robotics research.

Proposed method

  • The authors collected synchronized Lighthouse raw sensor data and onboard-processed position estimates using the Crazyflie 2.1 platform with the Lighthouse positioning deck.
  • Two position estimation methods were implemented: the Crossing Beam (C.B.) method and an Extended Kalman Filter (EKF) for state estimation.
  • The dataset includes raw IR signal timestamps, pulse widths, and base station sync times, enabling low-level processing and filtering.
  • Motion capture data from a high-precision system served as ground truth for accuracy evaluation across multiple scenarios (stationary, manual movement, flight).
  • Precision was quantified as RMS jitter using the standard deviation of position estimates over time.
  • Accuracy was measured via Euclidean error between Lighthouse estimates and motion capture ground truth, with mean and maximum error reported.

Experimental results

Research questions

  • RQ1How does the accuracy of the Lighthouse system compare between LH1 and LH2 when using real-time onboard tracking software on small UAVs?
  • RQ2What is the precision (jitter) of the Lighthouse system in different operational modes and hardware versions?
  • RQ3Can the Lighthouse system serve as a reliable ground truth for other localization systems like ultra-wideband (UWB)?
  • RQ4How does the sample frequency and stability vary between the C.B. and EKF estimation methods, especially for LH2 with periodic beam interference?
  • RQ5To what extent can the Lighthouse system replace motion capture systems in distributed UAV swarm research?

Key findings

  • LH2 achieved significantly better accuracy than LH1, with mean Euclidean errors of 1–4 cm in flight and stationary scenarios, and up to 18 cm in manual movement with high-speed motion.
  • The precision (jitter) of LH2 was higher than LH1, with 0.3 mm jitter using C.B. and 0.7 mm using EKF, compared to 0.6 mm and 3.9 mm respectively for LH1.
  • The sample frequency for the C.B. method was ~30 Hz for LH1 and ~34 Hz for LH2, though LH2 showed a large standard deviation (±18 Hz), likely due to beam interference and conservative filtering.
  • The EKF estimation method introduced higher jitter (3.9 mm for LH1, 0.7 mm for LH2) than the C.B. method, indicating that IMU noise or process noise contributed more to jitter than the Lighthouse signal itself.
  • Outliers in accuracy were most pronounced during fast manual movements and near the edge of the Lighthouse coverage volume, with errors reaching up to 18 cm for LH1 using C.B.
  • The dataset enables future improvements such as better filtering of raw data, enhanced metric selection in the C.B. method, and EKF tuning, with raw data provided for algorithmic development.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.