[Paper Review] Long term characterization of voltage references
This study characterizes eight off-the-shelf voltage references for long-term stability down to 0.1 mHz, focusing on noise and temperature coefficients to assess suitability for the eLISA space-based gravitational wave mission. Although no device fully meets the 1 ppm/√Hz requirement down to 0.1 mHz, the MAX6126AASA50, AD587UQ, LT1021-BCN8-5, and LTC6655BHM show the closest performance, with the LTC6655 emerging as a promising new bandgap-based candidate.
We report here the characterization (temperature coefficients and noise level) of selected voltage references in the frequency range from 10^(-5) to 10 Hz. The goal of this work is to update previous studies, with a characterization at lower frequencies, and find voltage references that may be suitable for the space-based interferometry mission eLISA. The requirements of relative output stability of 1 ppm/$\sqrt{ ext{Hz}}$ down to 0.1 mHz were not met by any of the tested devices, but 4 references approaches the objective : the AD587UQ, the MAX6126AASA50, the LT1021-BCN8-5 and the LT6655BHM. While the first three were already identified as potential devices in previous studies, the later is a new promising candidate using a different technology (bandgap).
Motivation & Objective
- To assess the long-term stability of commercial voltage references in the 0.1 mHz to 10 Hz frequency range, critical for eLISA's ultra-stable phase measurements.
- To identify voltage references that approach the stringent eLISA requirement of 1 ppm/√Hz down to 0.1 mHz.
- To evaluate the impact of temperature fluctuations on voltage reference stability using differential measurement techniques.
- To test the performance of newer technologies, such as bandgap references, in comparison to established buried zener and XFET types.
Proposed method
- Used a dual, identical voltage reference setup to isolate intrinsic noise by measuring the differential output, assuming each contributes half the total noise power.
- Employed a temperature-controlled bath cycling at 6°C peak-to-peak over 5,000 seconds to assess temperature-induced drift and extract temperature coefficients.
- Measured voltage noise using a low-noise amplifier and high-resolution digitizer, with data analyzed in the frequency domain via power spectral density (PSD) estimation.
- Calculated the differential temperature coefficient by comparing direct temperature measurements with differential voltage responses.
- Conducted long-term measurements over ~55 hours to assess low-frequency noise behavior and long-term drift.
- Rescaled manufacturer data (temperature drift, line regulation, noise) into ppm units for consistent comparison.
Experimental results
Research questions
- RQ1Which commercially available voltage references exhibit the lowest intrinsic voltage noise below 0.1 mHz, approaching eLISA's 1 ppm/√Hz requirement?
- RQ2How do temperature fluctuations affect the output stability of different voltage reference types at sub-mHz frequencies?
- RQ3Can the LTC6655BHM, a bandgap-based reference, match or exceed the performance of established buried zener references in ultra-low-noise environments?
- RQ4To what extent do XFET-based references (e.g., ADR445BRZ) exhibit excessive low-frequency noise, limiting their use in deep-space applications?
- RQ5How do the temperature coefficients of different voltage references correlate with their long-term stability and noise performance at low frequencies?
Key findings
- The MAX6126AASA50 exhibited the lowest overall noise and negligible temperature dependence, making it the most compatible with eLISA requirements across the 0.1 mHz to 10 Hz range.
- The LTC6655BHM, a bandgap-based reference, showed noise performance comparable to the best buried zener devices (e.g., AD587UQ and LT1021-BCN8-5), establishing it as a promising new candidate.
- The AD587UQ and LT1021-BCN8-5, both buried zener references, were marginally compatible with eLISA requirements, with the AD587UQ approaching the limit at 0.1 mHz due to high temperature coefficient.
- The XFET-based references (ADR445BRZ and ADR435BRZ) exhibited significantly higher low-frequency noise, with steep PSD slopes, rendering them unsuitable for eLISA’s stringent needs.
- All tested references except MAX6350 displayed a 1/f noise behavior below 10 mHz, indicating intrinsic electronic noise, while MAX6350 showed a step-like slope possibly due to slow drift.
- No tested device fully met the eLISA requirement of 1 ppm/√Hz down to 0.1 mHz, with the closest devices falling short by a factor of 2–5 at 0.1 mHz.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.