[Paper Review] M$^{2}$SNet: Multi-scale in Multi-scale Subtraction Network for Medical Image Segmentation
M2SNet introduces a multi-scale in multi-scale subtraction framework with a loss network to improve medical image segmentation by focusing on difference information across encoder levels and scales.
Accurate medical image segmentation is critical for early medical diagnosis. Most existing methods are based on U-shape structure and use element-wise addition or concatenation to fuse different level features progressively in decoder. However, both the two operations easily generate plenty of redundant information, which will weaken the complementarity between different level features, resulting in inaccurate localization and blurred edges of lesions. To address this challenge, we propose a general multi-scale in multi-scale subtraction network (M$^{2}$SNet) to finish diverse segmentation from medical image. Specifically, we first design a basic subtraction unit (SU) to produce the difference features between adjacent levels in encoder. Next, we expand the single-scale SU to the intra-layer multi-scale SU, which can provide the decoder with both pixel-level and structure-level difference information. Then, we pyramidally equip the multi-scale SUs at different levels with varying receptive fields, thereby achieving the inter-layer multi-scale feature aggregation and obtaining rich multi-scale difference information. In addition, we build a training-free network ``LossNet'' to comprehensively supervise the task-aware features from bottom layer to top layer, which drives our multi-scale subtraction network to capture the detailed and structural cues simultaneously. Without bells and whistles, our method performs favorably against most state-of-the-art methods under different evaluation metrics on eleven datasets of four different medical image segmentation tasks of diverse image modalities, including color colonoscopy imaging, ultrasound imaging, computed tomography (CT), and optical coherence tomography (OCT). The source code can be available at https://github.com/Xiaoqi-Zhao-DLUT/MSNet.
Motivation & Objective
- Motivate accurate medical image segmentation by leveraging rich multi-scale and inter-/intra-layer differential information.
- Replace traditional feature fusion (addition/concatenation) with subtraction-based aggregation to reduce redundancy.
- Develop an efficient intra-layer multi-scale subtraction unit to capture pixel- and region-level differences.
- Introduce LossNet to provide training-free, detail-to-structure supervision across feature levels.
- Demonstrate effectiveness across diverse modalities (colonoscopy, ultrasound, CT, OCT) and achieve competitive results on GOALS challenge.
Proposed method
- Define a basic subtraction unit (SU) to compute the difference between adjacent encoder features.
- Extend to an intra-layer multi-scale subtraction unit (MSU) using fixed filters of sizes 1x1, 3x3, 5x5 to capture multi-scale difference information without extra parameters.
- Construct inter-layer multi-scale subtraction by stacking and aggregating multiple MSUs across encoder levels to obtain rich cross-level differential features (CE^i).
- Use LossNet, a training-free supervisory network (based on a pre-trained classifier like VGG-16) to compute feature-level L2 losses between prediction and ground truth features, guiding detail-to-structure segmentation.
- Train end-to-end with a combined loss including weighted IoU, weighted BCE, and the L2 feature-guided loss L_f, promoting both boundary precision and structural accuracy.
Experimental results
Research questions
- RQ1Can subtraction-based feature fusion outperform addition/concatenation in medical image segmentation by reducing redundancy and enhancing discriminative difference information?
- RQ2Does a multi-scale in multi-scale subtraction (inter- and intra-layer) improve segmentation across diverse medical imaging modalities and structures?
- RQ3Can a training-free LossNet provide effective supervision from detail to structure without manual loss engineering?
- RQ4How does M2SNet perform on polyp, COVID-19 lung infection, breast ultrasound, and OCT layer segmentation tasks relative to state-of-the-art methods?
Key findings
- M2SNet achieves competitive to state-of-the-art performance across 4 medical segmentation tasks and 11 datasets, including polyp, COVID-19 CT, breast ultrasound, and OCT layer segmentation.
- On ColonDB, ETIS, Kvasir, CVC-T, and ClinicDB polyp datasets, M2SNet with R2-50 backbone achieves mDice/mIoU/Fβ^w/Eφ^max/MAE of 0.758/0.685/0.737/0.842/0.038 on ColonDB and 0.749/0.678/0.712/0.846/0.017 on ETIS, with corresponding gains over several baselines.
- On the MICCAI GOALS challenge, M2SNet contributed to a second-place finish among 100 teams.
- For COVID-19 lung CT, breast ultrasound, and GOALS OCT datasets, M2SNet with R2-50 backbone delivers improved metrics including higher Dice and lower MED/MAE compared to multiple baselines.
- The ablation studies show progressive performance gains when adding successive SU units and LossNet supervision, validating the effectiveness of inter-/intra-layer multi-scale subtraction and feature-level guidance.
- M2SNet maintains relatively low FLOPs and parameter counts while achieving strong accuracy, indicating efficient multi-scale subtraction with low computational overhead.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.