This paper presents mass composition studies of ultra-high-energy cosmic rays using the Pierre Auger Observatory's hybrid detection system, combining fluorescence and surface detectors to measure Xmax and its fluctuations. Using standard hadronic interaction models, the data indicate a transition from lighter to heavier composition around 2×10¹⁸ eV, correlated with a change in the cosmic ray energy spectrum's spectral index.

ABSTRACT

The determination of the mass composition of the highest energy cosmic rays is one of the greatest challenges in cosmic ray experiments. The highest energy cosmic rays are only detected indirectly because of their very low flux. Using the atmosphere as a large target, Air Fluorescence Detectors are capable of tracing the evolution of the size of the Extensive Air Shower through the atmosphere (the shower longitudinal profile). The analysis of the characteristics of the detected longitudinal profiles is currently the most reliable way for extracting some information about the primary cosmic ray mass composition. In this proceeding, I will describe in some detail the Pierre Auger elongation rate studies, and I will show the potential for mass composition studies using the surface and the fluorescence detectors information as part of a single analysis. The interpretation of the current data with regard to mass composition, relies heavily on high energy hadron interaction models. Using standard hadron interaction models, the data suggest that the composition becomes lighter up to about 2 $ imes$ 10$^{18}$ $eV$ and above that it becomes heavier again. This apparent change in the mass composition at 2 $ imes$ 10$^{18}$ $eV$ seems to be correlated with a spectrum index change in the observed energy spectrum.

Motivation & Objective

  • To determine the mass composition of the highest energy cosmic rays using longitudinal shower profiles measured by fluorescence detectors.
  • To investigate the correlation between the observed change in the cosmic ray energy spectrum's spectral index and a potential transition in mass composition.
  • To reduce systematic uncertainties in Xmax measurements by combining data from fluorescence and surface detectors in a hybrid analysis.
  • To explore additional surface detector parameters—such as rise time, shape parameter, and muon abundance—as independent indicators of primary particle mass.
  • To assess the impact of hadronic interaction model uncertainties on the interpretation of Xmax and elongation rate data.

Proposed method

  • Measures the longitudinal shower profile via fluorescence detectors to determine Xmax, the atmospheric slant depth at which the shower reaches maximum particle density.
  • Uses Monte Carlo simulations (e.g., QGSJET model) to predict Xmax and its fluctuations for proton and iron primaries under different hadronic interaction models.
  • Applies hybrid reconstruction by combining fluorescence detector data (for Xmax) with surface detector data (for signal rise time, shape parameter, and muon content) on a single event basis.
  • Analyzes Xmax fluctuations to distinguish between light (proton-like) and heavy (iron-like) primaries, noting that heavier nuclei exhibit narrower Xmax distributions.
  • Uses rise time (10% to 50% signal collection) and early-to-late signal ratios (shape parameter) in surface detector PMT traces to infer muon-to-electromagnetic component ratios.
  • Performs a multiparameter analysis combining Xmax, rise time, and asymmetry in signal arrival times around the shower axis to improve mass composition sensitivity.

Experimental results

Research questions

  • RQ1What is the mass composition of cosmic rays above 2×10¹⁸ eV, and does it change with energy?
  • RQ2Is the observed change in the cosmic ray energy spectrum's spectral index at ~2 EeV correlated with a transition in mass composition?
  • RQ3Can surface detector parameters like rise time and shape parameter provide independent and complementary constraints on mass composition?
  • RQ4To what extent do systematic uncertainties in Xmax measurements affect the interpretation of the elongation rate and mass composition trends?
  • RQ5Could a sudden change in hadronic interaction physics at high energies mimic a mass composition transition in the data?

Key findings

  • The mean Xmax values measured by the Pierre Auger Observatory indicate that cosmic rays become lighter in composition up to approximately 2×10¹⁸ eV.
  • Above 2×10¹⁸ eV, the data suggest a transition toward a heavier mass composition, as indicated by increasing Xmax values with energy.
  • This transition in mass composition correlates with a change in the spectral index of the cosmic ray energy spectrum, observed in the same energy range.
  • The elongation rate data show consistency with previous experiments at lower energies but reveal a potential trend toward heavier composition at higher energies (up to 5×10¹⁹ eV) where statistics are still improving.
  • Xmax fluctuations are narrower for iron showers than for proton showers, providing a secondary, independent signature for mass composition discrimination.
  • Surface detector parameters such as rise time and shape parameter show sensitivity to muon abundance, offering complementary mass composition constraints with independent systematics.