Skip to main content
QUICK REVIEW

[Paper Review] Maximum Entropy on Erroneous Predictions (MEEP): Improving model calibration for medical image segmentation

Agostina J. Larrazabal, César E. Martínez|arXiv (Cornell University)|Dec 22, 2021
Explainable Artificial Intelligence (XAI)Computer Science5 citations
TL;DR

This paper proposes Maximum Entropy on Erroneous Predictions (MEEP), a novel training strategy that improves model calibration in medical image segmentation by penalizing low entropy (overconfidence) only on misclassified pixels. By maximizing entropy for erroneous predictions via entropy or KL regularization, MEEP enhances uncertainty awareness without increasing model complexity, leading to significantly improved calibration and segmentation performance across multiple datasets and architectures.

ABSTRACT

Modern deep neural networks achieved remarkable progress in medical image segmentation tasks. However, it has recently been observed that they tend to produce overconfident estimates, even in situations of high uncertainty, leading to poorly calibrated and unreliable models. In this work we introduce Maximum Entropy on Erroneous Predictions (MEEP), a training strategy for segmentation networks which selectively penalizes overconfident predictions, focusing only on misclassified pixels. Our method is agnostic to the neural architecture, does not increase model complexity and can be coupled with multiple segmentation loss functions. We benchmark the proposed strategy in two challenging segmentation tasks: white matter hyperintensity lesions in magnetic resonance images (MRI) of the brain, and atrial segmentation in cardiac MRI. The experimental results demonstrate that coupling MEEP with standard segmentation losses leads to improvements not only in terms of model calibration, but also in segmentation quality.

Motivation & Objective

  • To address the critical issue of overconfident, poorly calibrated predictions in deep learning-based medical image segmentation.
  • To improve model reliability by enhancing uncertainty estimation, especially in high-uncertainty, misclassified regions.
  • To develop a training strategy that is architecture-agnostic, does not increase model complexity, and can be combined with standard segmentation losses.
  • To demonstrate that calibration metrics are essential alongside segmentation metrics for evaluating clinical AI models.
  • To show that focusing regularization on erroneous predictions yields better calibration than applying it globally.

Proposed method

  • Proposes two regularization terms: one directly maximizing entropy on misclassified pixels, and another using a KL divergence term as a proxy to encourage high uncertainty on wrong predictions.
  • Applies the regularization only to pixels that are misclassified during training, ensuring focus on hard, uncertain cases.
  • Integrates the regularization into the main loss function without modifying the network architecture or increasing inference cost.
  • Uses entropy-based regularization to push predicted probability distributions for misclassified pixels toward uniformity (high entropy), reducing overconfidence.
  • Employs a weighted version of the predicted mask ($\hat{Y}_w$) to focus the regularization on pixels with high uncertainty and misclassification.
  • Can be combined with standard segmentation losses such as Dice, cross-entropy, and focal loss, maintaining compatibility with existing training pipelines.

Experimental results

Research questions

  • RQ1Can penalizing low entropy on misclassified pixels improve model calibration in medical image segmentation?
  • RQ2Does focusing uncertainty regularization only on erroneous predictions lead to better calibration than global regularization?
  • RQ3Can MEEP be applied across different architectures and segmentation loss functions without increasing model complexity?
  • RQ4Does improved calibration via MEEP also lead to better segmentation performance?
  • RQ5How does MEEP compare to existing calibration techniques in terms of reliability and uncertainty estimation?

Key findings

  • MEEP significantly improves model calibration, reducing Brier score by up to 65% and ECE by up to 60% on the WMH dataset when combined with Dice or cross-entropy loss.
  • The method achieves state-of-the-art calibration performance, with the best results in Brier score (0.434 × 10⁻³) and ECE (0.174) on WMH using the KL regularizer with cross-entropy loss.
  • Segmentation performance (Dice coefficient) improved by up to 0.016 (1.6%) on WMH and 0.013 (1.4%) on LA when using MEEP with cross-entropy loss.
  • The proposed method is backbone-agnostic: similar improvements were observed on both UNet and ResUNet architectures, confirming its generalizability.
  • Qualitative results show that models trained with MEEP produce more balanced probability maps, with values near 0.5 on hard-to-segment pixels, indicating higher uncertainty.
  • The study demonstrates that relying solely on segmentation metrics like Dice is insufficient; calibration metrics such as Brier score and ECE are essential for evaluating clinical reliability.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.