Skip to main content
QUICK REVIEW

[Paper Review] Measurement of the temperature distribution inside a calorimeter

Ákos Sudár|arXiv (Cornell University)|May 5, 2020
Dark Matter and Cosmic PhenomenaPhysics and Astronomy2 citations
TL;DR

This paper investigates thermal management in a hadron-tracking calorimeter for proton CT (pCT) in hadron therapy, proposing and comparing two cooling concepts: liquid water cooling (Concept A) and air cooling (Concept B). Analytical and finite element modeling show both maintain safe temperatures (≤40 °C) with low gradients (≤1.8 °C), but Concept B achieves superior thermal homogeneity (1.6 °C max gradient) and lower cost, making it more suitable for clinical pCT systems.

ABSTRACT

Hadron therapy is a novel treatment against cancer. The main advantage of this therapy causes less side effect in comparison to X-ray irradiation methods. Hadron therapy is just ahead of a significant breakthrough since this technique can be more precise, applying proton computer tomograph (pCT) to map the stopping power in the tissues. The research and development of a pCT require a fast detector to measure the energy of hadrons behind the patient. The best detector option is called hadron-tracking calorimeter, which consists of sandwich layers of silicon tracking detectors and absorber layers. The combination of measuring the trajectory (tracking process), and, in parallel, the energy of relativistic particles, can provide high-resolution hadron imaging. This semiconductor-based technology requires stable temperature and homogeneous cooling. I have worked in the development of this detector in the Bergen pCT Collaboration for two years. Last year my work was to investigate the temperature distribution in the calorimeter and examine two cooling concepts in detail. I performed both analytical and numerical calculations to analyze the temperature distribution of the calorimeter. The final decision about the design takes into account many engineering aspects, such as reliability, flexibility, and performance.

Motivation & Objective

  • To ensure stable and homogeneous temperature distribution in a semiconductor-based hadron-tracking calorimeter for proton CT (pCT) applications.
  • To evaluate and compare two cooling concepts—liquid water cooling (Concept A) and forced-air cooling (Concept B)—for thermal management in the detector.
  • To assess thermal performance, cost, and environmental impact to guide the final design choice for the Bergen pCT Collaboration.
  • To model transient thermal behavior and determine the time to reach steady-state temperature distribution.
  • To evaluate the impact of contact thermal resistances and inhomogeneous heat loads on thermal performance using finite element analysis.

Proposed method

  • Developed analytical models to calculate steady-state temperature distributions in the calorimeter for both cooling concepts.
  • Applied finite element method (FEM) simulations to analyze thermal behavior, including contact thermal resistances and non-uniform heat loads.
  • Used thermal resistance and heat transfer coefficient models to quantify cooling efficiency in both concepts.
  • Calculated the time required to reach steady-state temperature distribution using transient thermal analysis.
  • Estimated costs and environmental impacts of both cooling systems to support engineering decision-making.
  • Validated results through comparison of maximum temperature, temperature gradients, and system reliability.

Experimental results

Research questions

  • RQ1What is the maximum temperature and temperature gradient in the calorimeter under both cooling concepts?
  • RQ2How do contact thermal resistances and non-uniform heat loads affect thermal performance in the water-cooled design?
  • RQ3What is the time required for the system to reach steady-state thermal conditions?
  • RQ4How do the costs and environmental impacts of water cooling (Concept A) and air cooling (Concept B) compare?
  • RQ5Which cooling concept provides better thermal homogeneity and reliability for clinical pCT applications?

Key findings

  • Both cooling concepts maintain the maximum temperature below the safe threshold of 40 °C.
  • The temperature gradient is 1.8 °C in Concept A (water cooling) and 1.6 °C in Concept B (air cooling), indicating superior thermal homogeneity in the air-cooled design.
  • The time required to reach steady-state temperature distribution is 134 seconds, which is suitable for clinical and test beam applications.
  • Finite element simulations show that realistic contact thermal resistances increase the maximum temperature difference by no more than 0.2 °C.
  • Non-uniform heat loading results in a lower maximum temperature difference than uniform loading, contrary to initial expectations.
  • Concept B (air cooling) is significantly cheaper than Concept A (water cooling), with potential for a third, Peltier-based cooling concept offering further cost and size advantages.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.