Skip to main content
QUICK REVIEW

[Paper Review] MMC Array to Study X-Ray Transitions in Muonic Atoms

Daniel Unger, A. Abeln|arXiv (Cornell University)|Nov 20, 2023
Atomic and Molecular PhysicsPhysics and Astronomy13 references1 citations
TL;DR

This paper presents a proof-of-principle experiment using a metallic magnetic calorimeter (MMC) array to perform high-resolution X-ray spectroscopy on muonic atoms of lithium, beryllium, and boron at the Paul Scherrer Institute. The setup features a novel refrigerator sidearm enabling close detector placement, achieving sub-eV energy resolution and enabling precision measurements of muonic X-ray transitions to improve absolute nuclear charge radii by factors of 3–20.

ABSTRACT

The QUARTET collaboration aims to significantly improve the precision of the absolute nuclear charge radii of light nuclei from Li to Ne by using an array of metallic magnetic calorimeters to perform high-precision X-ray spectroscopy of low-lying states in muonic atoms. A proof-of-principle measurement with lithium, beryllium and boron is planned for fall 2023 at the Paul Scherrer Institute. We discuss the performance achieved with the maXs-30 detector module to be used. To place the detector close to the target chamber where the muon beam will impact the material under study, we have developed a new dilution refrigerator sidearm. We further discuss the expected efficiency given the transparency of the X-ray windows and the quantum efficiency of the detector. The expected muonic X-ray rate combined with the high resolving power and detection efficiency of the detector suggest that QUARTET will be able to study the de-excitation of light muonic atoms at an unprecedented level, increasing the relative energy resolution by up to a factor of 20 compared to conventional detector techniques.

Motivation & Objective

  • To measure muonic X-ray transition energies in light elements (Li, Be, B) with unprecedented energy resolution.
  • To determine the absolute nuclear charge radii of light nuclei with improved precision by factors of 3–20.
  • To observe isotope shifts in muonic transitions between 6Li/7Li and 10B/11B.
  • To validate the use of metallic magnetic calorimeters (MMCs) for exotic atom spectroscopy.
  • To demonstrate a new experimental setup with a dedicated refrigerator sidearm for optimal detector positioning near the muon target.

Proposed method

  • The experiment uses a 64-pixel maXs-30 MMC array operating at 20 mK, read out via a two-stage SQUID system.
  • A new refrigerator sidearm enables close integration of the MMC detector array within 15 cm of the muon target chamber.
  • X-ray detection relies on energy deposition in a gold absorber, thermalization, and measurement of magnetic flux changes via a SQUID.
  • The system employs X-ray windows made of Mylar and beryllium, with future plans to reduce thickness to 1 µm to improve low-energy transmission.
  • Background suppression and monitoring are achieved using existing muon, electron, and photon detectors from the muX experiment.
  • Detector energy resolution is characterized by a full width at half maximum (FWHM) of 10 eV at 19 keV, enabling ppm-level precision on line positions.

Experimental results

Research questions

  • RQ1Can metallic magnetic calorimeters achieve the required energy resolution to measure muonic X-ray transitions with sub-eV precision?
  • RQ2What is the expected X-ray detection efficiency for muonic transitions in 7Li, 9Be, and 11B, considering window and absorber transmission?
  • RQ3Can the new refrigerator sidearm configuration enable sufficient detector proximity to the muon target to achieve measurable X-ray rates?
  • RQ4What is the expected muonic X-ray count rate on the MMC array for a 10 kHz muon beam?
  • RQ5Can the system resolve isotope shifts in muonic transitions between 6Li/7Li and 10B/11B with the planned setup?

Key findings

  • The maXs-30 MMC array achieves a full width at half maximum (FWHM) energy resolution of 10 eV at 19 keV, enabling ppm-level precision on muonic X-ray line positions.
  • The expected detection efficiency for the 2p–1s transition in 7Li is 97% at 19 keV, with 59% efficiency for 9Be at 33 keV and 22% for 11B at 53 keV.
  • The estimated muonic X-ray rate on the MMC array is approximately 0.15 s⁻¹ for the 2p–1s transition in 7Li, well within the detector’s handling capacity.
  • The combined efficiency of the X-ray windows and absorber is above 20% between 2 keV and 50 keV, with potential for >20% improvement at low energies if window thickness is reduced to 1 µm.
  • A few hours of measurement time are sufficient to achieve the required statistical precision for a 0.1 eV resolution goal, given the expected event rate and detector performance.
  • This is the first application of MMCs to study exotic atoms, marking a significant advancement in high-precision X-ray spectroscopy of muonic systems.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.