Skip to main content
QUICK REVIEW

[Paper Review] Mobile phone identification through the built-in magnetometers

Gianmarco Baldini, Gary Steri|arXiv (Cornell University)|Jan 26, 2017
Digital Media Forensic DetectionComputer Science4 references4 citations
TL;DR

This paper proposes a novel method to identify mobile phones using their built-in magnetometers by stimulating them with controlled waveforms via a solenoid and analyzing the resulting digital output using statistical features and Support Vector Machine (SVM) classification. It demonstrates high accuracy in distinguishing between different phone models and brands (inter-model), but only limited accuracy in distinguishing between phones of the same model (intra-model), with waveform complexity improving verification performance.

ABSTRACT

Mobile phones identification through their built in components has been demonstrated in literature for various types of sensors including the camera, microphones and accelerometers. The identification is performed by the exploitation of the small but significant differences in the electronic circuits generated during the production process. Thus, these differences become an intrinsic property of the electronic components, which can be detected and become an unique fingerprint of the component and of the mobile phone. In this paper, we investigate the identification of mobile phones through their builtin magnetometers, which has not been reported in literature yet. Magnetometers are stimulated with different waveforms using a solenoid connected to a computer s audio board. The identification is performed analyzing the digital output of the magnetometer through the use of statistical features and the Support Vector Machine (SVM) machine learning algorithm. We prove that this technique can distinguish different models and brands with very high accuracy but it can only distinguish phones of the same model with limited accuracy.

Motivation & Objective

  • To investigate whether mobile phone magnetometers can serve as unique physical fingerprints for device identification.
  • To evaluate the feasibility of inter-model and intra-model identification using magnetometer outputs.
  • To assess the robustness of the method under noise and temporal variations.
  • To determine the impact of different stimulation waveforms on identification accuracy.

Proposed method

  • A solenoid connected to a computer's audio output was used to generate controlled magnetic field waveforms to stimulate the magnetometers in mobile phones.
  • Digital output signals from the magnetometers were collected and processed to extract statistical features such as mean, variance, skewness, and kurtosis.
  • Support Vector Machine (SVM) classification was applied to distinguish between different phones based on their magnetometer responses.
  • Multiple stimulation waveforms (A, B, and C) of varying lengths and complexities were tested to evaluate their impact on identification accuracy.
  • Additive White Gaussian Noise (AWGN) was introduced to simulate real-world signal degradation and assess robustness.
  • Verification performance was evaluated using Equal Error Rate (EER) across multiple days to test temporal stability.

Experimental results

Research questions

  • RQ1Can mobile phones be uniquely identified based on the intrinsic variations in their built-in magnetometers?
  • RQ2How accurate is inter-model identification (between different brands and models) using magnetometer fingerprints?
  • RQ3To what extent can intra-model identification (between same-model phones) be achieved with this method?
  • RQ4How do different stimulation waveforms affect the identification accuracy and training time?
  • RQ5How robust is the identification system under additive Gaussian noise and temporal variations?

Key findings

  • Inter-model identification achieved very high accuracy, with an average Equal Error Rate (EER) of 0.00303 for the most complex waveform (C).
  • Intra-model identification showed limited accuracy, with an average EER of 0.195 for the best-performing waveform (C), indicating moderate but not strong distinction between same-model phones.
  • The method demonstrated high temporal stability, with EER values near random chance (EER ≈ 0.5) when comparing the same phone across different days.
  • Gaussian noise significantly degraded performance, with EER rising to 0.43 at SNR = 0, indicating sensitivity to signal attenuation.
  • Longer and more complex waveforms (e.g., waveform C) improved identification accuracy compared to shorter or simpler waveforms, though at the cost of increased processing time.
  • The combination of statistical feature extraction and SVM classification enabled reliable classification and verification of mobile phones based on magnetometer responses.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.