TL;DR

This paper presents a model-driven approach for designing clinical guidance systems using organ-centric finite state machines and a physician interaction model, formally verified via UPPAAL with CTL formulas. The method enables executable, verifiable, and clinically reviewable models that support real-time decision support in acute care, with successful code generation and integration for cardiac arrest management.

ABSTRACT

Clinical guidance systems have been widely adopted to help medical staffs to avoid preventable medical errors such as delay in diagnosis, treatment or untended deviations from best practice guidelines. However, because patient condition changes rapidly and medical staffs are usually overloaded in acute care setting, how to ensure the correctness of the system reaction to those rapid changes and managing interaction with physicians remains challenging. In this paper, we propose a domain-specific model-driven design approach to address these challenges for designing clinical guidance systems. Firstly, we translate the relevant medical knowledge described in generic literature and different best practice guidelines into a set of executable and indirectly verifiable finite state machine models. We introduce an organ-centric paradigm to construct clinical models, and also develop a physician model to track physician-system interactions and deviations. Secondly, for verification of the compositional system model, we translate the model into timed automata, based on which, we formalize a set of clinical and system safety requirements as computation tree logic(CTL) formulas and use the UPPAAL model checking tool to formally verify those requirements. In this way, the correctness of the model can be mathematically proved. Finally, we can automatically generate the executable code from the verified model using the corresponding code generation tools for finite state machine. For evaluation, we apply the approach to the design of clinical guidance systems for cardiac arrest. The generated code can be deployed and interact with existing guidance systems.

Motivation & Objective

  • Address the challenge of ensuring correctness and safety in clinical guidance systems amid rapid patient state changes and high clinical workloads.
  • Overcome limitations of procedural coding by enabling physician-in-the-loop validation of clinical knowledge through high-level, executable models.
  • Develop a cyber-medical-human model that integrates patient state, best practice guidelines, and physician-system interaction tracking.
  • Formally verify clinical and system safety requirements using timed automata and model checking to mathematically prove correctness.
  • Enable automatic code generation from verified models for deployment in real-world clinical systems.

Proposed method

  • Translate medical knowledge and best practice guidelines into executable finite state machine models using an organ-centric paradigm.
  • Model physician-system interactions via a compositional physician model to track deviations and interventions.
  • Use Yakindu Statecharts for interactive modeling and simulation to support dynamic clinical validation by physicians.
  • Manually translate the Yakindu models into UPPAAL for formal verification using computation tree logic (CTL) formulas.
  • Formalize clinical and system safety requirements as CTL properties and verify them using the UPPAAL model checker.
  • Automatically generate Java code from the verified Yakindu model for integration with existing clinical guidance systems.

Experimental results

Research questions

  • RQ1How can clinical guidance systems be designed to ensure correctness under rapid patient state changes and high clinical workloads?
  • RQ2Can a model-driven approach with physician-recognizable abstractions improve clinical validation and reduce errors in system design?
  • RQ3To what extent can formal verification via timed automata and CTL logic ensure safety and correctness of clinical guidance models?
  • RQ4How effectively can executable, verifiable, and human-readable models be generated and integrated into real clinical systems?
  • RQ5Can the integration of physician interaction modeling enhance system adaptability and adherence to best practice guidelines?

Key findings

  • The organ-centric finite state machine model successfully represents complex clinical conditions such as metabolic acidosis with clear, traceable state transitions.
  • Physicians were able to validate and refine the models using Yakindu simulations, confirming the approach supports clinical review at a meaningful abstraction level.
  • Formal verification using UPPAAL confirmed key safety properties, including correct handling of physician deviations (e.g., property P8 ensures deviation counter increments when both best practice and normal blood gas levels are present).
  • The model-driven pipeline enabled automatic code generation from verified models, which was successfully integrated with an existing guidance system for cardiac arrest.
  • Properties such as P7 confirmed that the physician model correctly reflects system states, ensuring accurate tracking of clinical interactions.
  • The approach demonstrated feasibility in a real case study, with verified models and generated code suitable for deployment in acute care environments.