[Paper Review] Module Technology for Agrivoltaics: Vertical Bifacial vs. Tilted Monofacial Farms
This study compares vertical bifacial East/West (E/W) PV farms with traditional North/South (N/S) tilted monofacial farms in agrivoltaic systems, using a computational model to analyze PAR transmission and energy yield. It finds that at half or lower array density, vertical bifacial farms match monofacial farms in energy and photosynthetic radiation (PAR) output, while offering advantages in soiling resistance, land use, and maintenance—making them ideal for hot, arid climates with high soiling risks.
Agrivoltaics is an innovative approach in which solar photovoltaic (PV) energy generation is collocated with agricultural production to enable food-energy-water synergies and landscape ecological conservation. This dual-use requirement leads to unique co-optimization challenges (e.g. shading, soiling, spacing) that make module technology and farm topology choices distinctly different from traditional solar farms. Here we compare the performance of the traditional optimally-titled North/South (N/S) faced monofacial farms with a potential alternative based on vertical East/West (E/W)-faced bifacial farms. Remarkably, the vertical farm produces essentially the same energy output and photosynthetically active radiation (PAR) compared to traditional farms as long as the PV array density is reduced to half or lower relative to that for the standard ground-mounted PV farms. Our results explain the relative merits of the traditional mono facial vs. vertical bifacial farms as a function of array density, acceptable PAR-deficit, and energy production. The combined PAR/Energy yields for the vertical bifacial farm may not always be superior, it could still be an attractive choice for agrivoltaics due to its distinct advantages such as minimum land coverage, least hindrance to the farm machinery and rainfall, inherent resilience to PV soiling, easier cleaning and cost advantages due to potentially reduced elevation.
Motivation & Objective
- To evaluate the performance trade-offs between vertical bifacial E/W and traditional N/S tilted monofacial PV farms in agrivoltaic systems.
- To quantify the impact of array density on photosynthetic active radiation (PAR) transmission and photovoltaic (PV) energy yield.
- To assess the practical advantages of vertical bifacial farms, including reduced soiling, easier cleaning, and minimal land and machinery obstruction.
- To provide a computational framework for predicting sunlight interception and PAR transmission under elevated PV arrays.
- To compare the relative land productivity and system efficiency of different module technologies and farm topologies in agrivoltaics.
Proposed method
- A rigorous analytical model calculates direct and diffuse solar irradiance intercepted by elevated PV arrays and transmitted PAR below them.
- The model accounts for panel tilt, orientation, array density (p/h ratio), and geometric shading between rows.
- Empirical temperature correction is applied using King et al.‘s model to estimate cell temperature and efficiency loss based on ambient temperature, irradiance, and wind speed.
- Model validation is performed using field data from Montpellier, France, comparing simulated and measured global horizontal irradiance (GHI) and PV energy output.
- The study evaluates performance across three array density configurations: full (p/h ≈ 4), half (p/h ≈ 2.6), and quarter (p/h ≈ 2) densities.
- The levelized performance factor (LPF) is used to compare relative energy and PAR yields across different configurations.
Experimental results
Research questions
- RQ1How do vertical bifacial E/W and traditional N/S tilted monofacial PV farms compare in terms of annual energy yield and PAR transmission at varying array densities?
- RQ2What array density is required for vertical bifacial E/W farms to achieve PAR transmission levels comparable to standard N/S monofacial farms?
- RQ3How does adjusting the tilt angle of N/S panels affect the balance between PV energy generation and PAR availability for crops?
- RQ4What are the relative advantages of vertical bifacial farms in terms of soiling resistance, land coverage, and maintenance accessibility?
- RQ5How does the temperature effect influence PV output in both system configurations, and how is it modeled?
Key findings
- At half or lower array density (p/h ≤ 4), vertical bifacial E/W farms produce comparable annual energy yields and PAR transmission (80%) to traditional N/S monofacial farms.
- For full-density arrays, the relative PV yield of vertical bifacial E/W drops to 80% while PAR transmission falls to 55–65%, indicating a trade-off favoring crop yield at the cost of energy.
- The levelized performance factor (LPF) for half-density configurations is 1.3–1.35, indicating balanced performance between energy and PAR yields.
- The N/S tilt angle can be adjusted between 20° and 60° to fine-tune the sunlight balance, enabling a modulation capability of 10–15% in PAR transmission.
- Vertical bifacial E/W farms exhibit significantly lower soiling losses due to near-vertical orientation, which reduces dust accumulation and improves long-term efficiency.
- The model validation shows strong agreement with field data from Montpellier, France, confirming accuracy in predicting GHI and PV energy output under real conditions.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.