[Paper Review] Moving Beyond Simulation: Data-Driven Quantitative Photoacoustic Imaging Using Tissue-Mimicking Phantoms.

Janek Gröhl, Thomas R. Else|arXiv (Cornell University)|Jun 11, 2023
Photoacoustic and Ultrasonic ImagingEngineering5 citations
TL;DR

This study introduces a novel dataset of experimentally characterized tissue-mimicking phantoms and their digital twins to enable supervised deep learning for quantitative photoacoustic imaging. Training a U-Net on real experimental data significantly outperformed simulation-based training, reducing domain gap-induced biases and improving absorption coefficient estimation accuracy over Monte Carlo fluence correction, which had ~20% error.

ABSTRACT

Accurate measurement of optical absorption coefficients from photoacoustic imaging (PAI) data would enable direct mapping of molecular concentrations, providing vital clinical insight. The ill-posed nature of the problem of absorption coefficient recovery has prohibited PAI from achieving this goal in living systems due to the domain gap between simulation and experiment. To bridge this gap, we introduce a collection of experimentally well-characterised imaging phantoms and their digital twins. This first-of-a-kind phantom data set enables supervised training of a U-Net on experimental data for pixel-wise estimation of absorption coefficients. We show that training on simulated data results in artefacts and biases in the estimates, reinforcing the existence of a domain gap between simulation and experiment. Training on experimentally acquired data, however, yielded more accurate and robust estimates of optical absorption coefficients. We compare the results to fluence correction with a Monte Carlo model from reference optical properties of the materials, which yields a quantification error of approximately 20%. Application of the trained U-Nets to a blood flow phantom demonstrated spectral biases when training on simulated data, while application to a mouse model highlighted the ability of both learning-based approaches to recover the depth-dependent loss of signal intensity. We demonstrate that training on experimental phantoms can restore the correlation of signal amplitudes measured in depth. While the absolute quantification error remains high and further improvements are needed, our results highlight the promise of deep learning to advance quantitative PAI.

Motivation & Objective

  • To close the domain gap between simulated and experimental photoacoustic imaging data that hinders accurate optical property estimation.
  • To develop a reliable, data-driven approach for quantitative photoacoustic imaging using real experimental phantoms with known optical properties.
  • To evaluate whether deep learning models trained on experimental data can improve absorption coefficient estimation compared to traditional fluence correction methods.
  • To validate the performance of learned models on pre-clinical in vivo data, demonstrating potential for clinical translation.

Proposed method

  • Fabricated 137 cylindrical tissue-mimicking phantoms using co-polymer-in-oil formulations with tunable absorption (µa = 0.05–4.0 cm⁻¹) and reduced scattering (µ′s = 5–15 cm⁻¹) at 800 nm.
  • Measured optical properties using a double integrating sphere (DIS) system to establish reference ground truth, with uncertainty estimated at ~20%.
  • Generated digital twins of the phantoms using Monte Carlo simulations and k-space acoustic modeling to create paired simulated and experimental PA image data.
  • Trained U-Net neural networks on both simulated and experimental PA images to predict pixel-wise absorption coefficients (µa).
  • Applied trained models to unseen test phantoms and in vivo mouse data to assess generalization and depth-dependent signal recovery.
  • Compared learned methods to Monte Carlo-based fluence correction, using DIS-measured optical properties as reference.

Experimental results

Research questions

  • RQ1Can deep learning models trained on experimental photoacoustic data outperform those trained on simulated data in estimating optical absorption coefficients?
  • RQ2To what extent does the domain gap between simulation and experiment degrade the accuracy of quantitative photoacoustic imaging?
  • RQ3How do learned models compare to conventional fluence correction methods in terms of quantification error and depth-dependent signal recovery?
  • RQ4Can data-driven models trained on phantoms generalize to in vivo pre-clinical data, preserving signal amplitude correlation with depth?
  • RQ5What are the primary sources of error in the reference optical property measurements and how do they affect model performance?

Key findings

  • Training the U-Net on experimental data yielded more accurate and robust absorption coefficient estimates than training on simulated data, which introduced artefacts and biases.
  • The Monte Carlo-based fluence correction method achieved a quantification error of approximately 20%, serving as a performance benchmark.
  • On test phantoms, the experimental-data-trained U-Net reduced spectral biases compared to the simulation-trained model, especially in depth-dependent signal estimation.
  • Application to a blood flow phantom revealed that simulation-trained models exhibited wavelength-dependent biases, while experimental-trained models preserved signal amplitude trends with depth.
  • In the mouse model, both learning-based approaches successfully recovered the depth-dependent loss of signal intensity, demonstrating improved correlation with depth compared to baseline methods.
  • Despite these advances, absolute quantification error remains high, and uncertainties in DIS measurements (~20%) and modeling approximations (e.g., 2D acoustics, homogeneous materials) limit further improvement.