[Paper Review] MRSegmentator: Multi-Modality Segmentation of 40 Classes in MRI and CT
MRSegmentator is a deep learning model that segments 40 anatomical structures in MRI and CT, using cross-modality transfer learning and a human-in-the-loop annotation workflow, with strong cross-dataset generalization.
Purpose: To develop and evaluate a deep learning model for multi-organ segmentation of MRI scans. Materials and Methods: The model was trained on 1,200 manually annotated 3D axial MRI scans from the UK Biobank, 221 in-house MRI scans, and 1228 CT scans from the TotalSegmentator dataset. A human-in-the-loop annotation workflow was employed, leveraging cross-modality transfer learning from an existing CT segmentation model to segment 40 anatomical structures. The annotation process began with a model based on transfer learning between CT and MR, which was iteratively refined based on manual corrections to predicted segmentations. The model's performance was evaluated on MRI examinations obtained from the German National Cohort (NAKO) study (n=900) from the AMOS22 dataset (n=60) and from the TotalSegmentator-MRI test data (n=29). The Dice Similarity Coefficient (DSC) and Hausdorff Distance (HD) were used to assess segmentation quality, stratified by organ and scan type. The model and its weights will be open-sourced. Results: MRSegmentator demonstrated high accuracy for well-defined organs (lungs: DSC 0.96, heart: DSC 0.94) and organs with anatomic variability (liver: DSC 0.96, kidneys: DSC 0.95). Smaller structures showed lower accuracy (portal/splenic veins: DSC 0.64, adrenal glands: DSC 0.69). On external validation using NAKO data, mean DSC ranged from 0.85 $\pm$ 0.08 for T2-HASTE to 0.91 $\pm$ 0.05 for in-phase sequences. The model generalized well to CT, achieving mean DSC of 0.84 $\pm$ 0.11 on AMOS CT data. Conclusion: MRSegmentator accurately segments 40 anatomical structures in MRI across diverse datasets and imaging protocols, with additional generalizability to CT images. This open-source model will provide a valuable tool for automated multi-organ segmentation in medical imaging research. It can be downloaded from https://github.com/hhaentze/MRSegmentator.
Motivation & Objective
- Address the lack of robust, multi-organ MRI segmentation tools across diverse sequences and modalities.
- Develop a single open-source model capable of segmenting 40 anatomical structures in pelvic, abdominal, and thoracic regions.
- Leverage cross-modality transfer learning from CT segmentation models and a human-in-the-loop annotation workflow to improve data quality and generalizability.
- Evaluate the model on external datasets (NAKO MRI and AMOS22) to assess cross-dataset performance and robustness.
Proposed method
- Train a multi-organ segmentation model on 1,200 UK Biobank MRI scans, 221 in-house MRI scans, and 1,228 CT scans.
- Use cross-modality transfer learning from CT segmentation models to aid MRI segmentation.
- Adopt a human-in-the-loop annotation workflow with pre-segmentation (TotalSegmentator) and iterative model retraining ( nnUNet ) after every 50 annotated examinations.
- Annotate 40 classes covering chest, abdomen, pelvis, and Vessels as detailed in Table 2, merging vertebrae into a single spine label and omitting lung lobes.
- Train final model with five-fold cross-validation on fully annotated images.
- Evaluate using Dice Similarity Coefficient (DSC) and Hausdorff Distance (HD), including 95th percentile HD.

Experimental results
Research questions
- RQ1How well can a single multi-structure model segment 40 organs in both MRI and CT across diverse sequences and scanners?
- RQ2Does incorporating CT data via cross-modality learning improve MRI segmentation performance and generalizability?
- RQ3What is the model’s performance stability across external datasets (NAKO MRI and AMOS22) and modalities (MRI and CT)?
- RQ4What are the limitations and failure modes for small vessels and adrenal structures in multi-organ MRI/CT segmentation?
Key findings
- On the external MRI datasets, mean DSCs were 0.85 ± 0.13 (NAKO) and 0.79 ± 0.11 (AMOS22).
- On MRI, mean DSCs across external data indicate robust performance with 0.86–0.84 DSCs for selected sequences (e.g., T1 GRE OPP and T1 GRE F).
- On CT data from AMOS22, mean DSC was 0.84 ± 0.11 with HD 7.86 ± 11.12 mm.
- Lungs (left and right) achieved the highest DSC on NAKO (0.97 each); portal/splenic vein and adrenal glands showed lower DSCs (0.54 and 0.65/0.61 respectively).
- Overall, MRSegmentator achieved competitive performance compared to specialized models, with strong multi-organ and cross-modality generalizability.

Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.