[Paper Review] Multi-Label Retinal Disease Classification using Transformers
This paper proposes a novel transformer-based model, C-Tran, for multi-label retinal disease classification using a newly constructed MuReD dataset of 2,208 fundus images across 20 diseases. The approach achieves state-of-the-art performance, outperforming prior methods by 7.9% and 8.1% in AUC for disease detection and classification, respectively, with high accuracy and interpretability via class activation maps.
Early detection of retinal diseases is one of the most important means of preventing partial or permanent blindness in patients. In this research, a novel multi-label classification system is proposed for the detection of multiple retinal diseases, using fundus images collected from a variety of sources. First, a new multi-label retinal disease dataset, the MuReD dataset, is constructed, using a number of publicly available datasets for fundus disease classification. Next, a sequence of post-processing steps is applied to ensure the quality of the image data and the range of diseases, present in the dataset. For the first time in fundus multi-label disease classification, a transformer-based model optimized through extensive experimentation is used for image analysis and decision making. Numerous experiments are performed to optimize the configuration of the proposed system. It is shown that the approach performs better than state-of-the-art works on the same task by 7.9% and 8.1% in terms of AUC score for disease detection and disease classification, respectively. The obtained results further support the potential applications of transformer-based architectures in the medical imaging field.
Motivation & Objective
- To address the challenge of simultaneous detection of multiple retinal diseases in fundus images, which is underexplored in existing automated systems.
- To construct a high-quality, multi-label fundus image dataset (MuReD) by integrating and cleaning data from multiple public sources.
- To develop and optimize a transformer-based deep learning model (C-Tran) for multi-label retinal disease classification, overcoming limitations of traditional CNNs and handcrafted features.
- To evaluate model performance on both individual disease detection and multi-disease classification, with interpretability via class activation maps.
- To demonstrate the superiority of transformer architectures over existing state-of-the-art methods in multi-label retinal diagnosis.
Proposed method
- Constructed the MuReD dataset by aggregating and cleaning images from three public fundus datasets, ensuring a minimum of 50 samples per disease class and applying automated quality assessment.
- Applied a sequence of post-processing steps including image normalization, disease label standardization, and filtering to enhance data quality and consistency.
- Designed a custom vision transformer architecture (C-Tran) optimized through extensive hyperparameter tuning for multi-label classification of retinal diseases.
- Utilized a multi-head self-attention mechanism to capture long-range dependencies in fundus images, replacing or augmenting traditional convolutional layers.
- Employed a sigmoid activation function with binary cross-entropy loss for multi-label output, enabling independent prediction of each disease.
- Generated class activation maps (CAMs) using Grad-CAM to visualize attention regions and validate model interpretability and feature learning.
Experimental results
Research questions
- RQ1Can a transformer-based architecture outperform existing CNN-based models in multi-label retinal disease classification using fundus images?
- RQ2How does the performance of the proposed C-Tran model compare to state-of-the-art methods in terms of AUC for disease detection and classification?
- RQ3To what extent does the model learn discriminative features for different diseases, as validated by class activation maps?
- RQ4What are the main challenges in multi-label fundus image classification, particularly regarding rare or subtle diseases like ODP, HTR, and ASR?
- RQ5How effective is the proposed MuReD dataset in supporting robust and generalizable multi-label learning in retinal disease diagnosis?
Key findings
- The proposed C-Tran model achieved a 7.9% improvement in AUC score for disease detection and an 8.1% improvement for disease classification compared to state-of-the-art methods.
- The model achieved AUC scores above 90% for 18 out of 20 diseases, with the highest AUC of 0.999 for the ODE class and 0.997 for MYA.
- The model demonstrated high confidence and accuracy in detecting major pathologies: 99% confidence for glaucoma (ODC), 98% for ARMD, and 100% for myopia (MYA).
- The model struggled most with the 'OTHER' class (AUC = 0.851) and 'ODP' (AUC = 0.870), due to its role as an umbrella category and subtle visual cues, respectively.
- Class activation maps confirmed that the model focuses on clinically relevant regions—such as neovascular membranes for ARMD and optic disc cupping for glaucoma—validating its interpretability and feature learning capability.
- For HTR and ASR, the model achieved high AUC (0.971 and 0.911) but failed to produce F1 scores due to low confidence predictions below the 0.5 threshold, indicating a need for better calibration or data augmentation.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.